LogicCommons is in beta. If a result, label, or reference looks wrong, tell us here; we read every message.
Methodology
Purpose and model boundary
This calculator takes a steel pipe rack drawn on the page and returns two things. The first is a member takeoff of the whole rack: counts, lengths and weights by member type and by section. The second is a 2D analysis of one typical bent under the loads you apply to it. A rack is a row of repeated bents (two columns and one beam per tier) joined along its length by struts at the tiers, with X bracing in the bays you choose.
The analysis covers the typical bent only, in its own plane across the rack. It returns the base reactions, each node's displacement and rotation, each member's axial force, shear and bending moment along its length, the drift and a per-tier summary of the loads you applied.
It is a linear elastic analysis only, for learning and estimating. It makes no strength, stability, second-order, load-combination, drift-limit or code check, and it gives no verdict on any rack. The struts and braces are counted in the takeoff but not analysed.
The model is the calculation authority. The page sends the drawn geometry and the values you type to the model and draws only what the model returns; it computes no engineering value itself.
Inputs and units
The rack is drawn on the canvas, in plan, in the bent elevation, along each column line and in 3D:
- 2 to 15 bents, each at its own spacing along the rack;
- the width (the beam span) and the column height;
- 1 to 4 tiers, each with or without struts between the bents;
- X bracing per bay and column line, from the base to the lowest tier.
The canvas writes every node and member: up to 400 nodes and 400 members. Each bent's columns and beams carry the group BENT-1, BENT-2 and so on, numbered along the rack.
The typical bent is the bent you pick on the plan; it is sent as its group, for example BENT-2.
Base fixity: every base of the typical bent is pinned or fixed. Click a base symbol on the bent to switch it.
Sections are defined in the Sections grid, up to 12:
- a name and a profile (I, C, L, HSS, PIPE, RECT, or PROPS to type the area A and the moment of inertia Ix yourself);
- the dimensions that profile reads.
You assign them on the canvas, by member, by box or by member type. The model returns each section's A, Ix and weight per length.
Loads on the typical bent are drawn on the Bent view:
- up to 20 loads at its nodes, each a horizontal force across the rack, a vertical force and a moment (a blank component is zero);
- up to 30 uniform loads along whole members. A member load acts across the rack or vertically per unit of member length, per unit of the member's vertical or horizontal projection, or at right angles to the member.
A point load inside a member splits the member at a new node, in the typical bent only. A tier's presets add a pipe load along the tier beam or a lateral force at the tier's two nodes, as ordinary loads you can then edit.
Material:
- the modulus of elasticity E, used for every member (about 29,000 ksi or 200,000 MPa for structural steel);
- an optional density. With a density the model gives the member weights.
Include the self-weight adds each typical bent member's own weight as a downward load along its length.
Units:
- US works in feet, kips and inches for section dimensions and displacements;
- Metric works in metres, kilonewtons and millimetres.
Every value you type and every result follows this choice. Switching converts the drawing by exact factors.
Axes: x runs along the rack, y across it (column line A at y = 0, line B at the width) and z up. In the model a force across the rack is positive along +y, vertical loads are positive up (so gravity is negative) and moments are counterclockwise positive, seen with y to the right and z up. The canvas lets you type a vertical load as a downward size and a moment as a clockwise size, and sends them with the model's signs.
Governing relationships
- Takeoff: each member's length is the distance between its end nodes. Its weight is the length times the section's area times the density.
- The typical bent is solved by linear elastic 2D frame theory, the direct stiffness method with rigid joints and finite axial stiffness (EA), in the bent's plane (y, z).
- Equilibrium: the reactions plus the loads add up to zero across the rack, vertically and in moment, up to rounding.
- The drift ratio is the height of the node that moves sideways the most, above the base, divided by its sideways displacement, so 150 means H/150.
Calculation sequence
- The model checks the inputs, the drawn rows and the typical bent. An invalid input reads NOT VALID with the first input to fix, and every number is then blank.
- It measures every member and adds up the counts, lengths and weights by member type, by section and in total.
- It takes the typical bent: the columns and beams of the chosen group, at most 16 nodes and 24 members, all in one plane across the rack. Its tiers are the distinct elevations of its beams.
- It solves the bent, with the chosen fixity at every base node and the loads you applied, plus the self-weight when it is included.
- It reports the base reactions, the node displacements and rotations, and the member end forces. It also gives eleven points along each bent member (its start, every tenth of its length and its end), from which the canvas draws the axial force, shear and moment diagrams and the deflected shape on the bent.
- It reports the tier summary: each tier's elevation and beam length, the gravity and lateral loads you applied at that tier, and the gravity load at and above it.
- It reports the equilibrium residuals, which should be zero up to rounding, and the totals of the applied loads and the reactions.
Outputs and interpretation
- Takeoff: the member and node counts, the number of bents, the total member length, weight and tonnage, and the schedules by member type and by section (with each section's A, Ix and weight per length).
- Tier summary: for the typical bent, per tier, the gravity load and the lateral load you applied on its beams and at its nodes (self-weight excluded), and the gravity load the columns carry just below it.
- Base reactions: for each base node of the typical bent, the force across the rack RY, the vertical force RZ and, for a fixed base, the moment MX that the base applies to the bent.
- Node results: each bent node's displacement across the rack and vertically (in or mm) and its rotation (radians, counterclockwise positive); the largest sideways displacement, its node, its height and the drift ratio.
- Member results: each bent member's length, weight, axial force N, shear V and moment M at its start and end, and its largest and smallest moment with their distances from the start node. The largest positive and most negative moments, the largest tension and compression, the largest shear and the largest sampled vertical displacement are each given with their member.
Member forces are internal forces. N is tension positive. A positive bending moment puts the side to the right of the member's start-to-end direction in tension. Reactions are what the bases apply to the bent. Loads on columns, or at nodes not at a tier elevation, are in the analysis but in no tier row.
Validation and status logic
The status reads OK when the rack was measured and the bent analysed, or NOT VALID followed by the first input to fix. Every number is blank under NOT VALID.
Assumptions and limitations
- Linear elastic analysis of one typical bent only, in its own plane: no strength, stability, second-order, load-combination, drift-limit or code check. The struts and braces are not analysed.
- One modulus of elasticity for every member; each member is straight and prismatic, and every joint is rigid.
- Member loads are uniform along whole members; a point load inside a member is placed by splitting the member at a node.
- The member diagrams are drawn from eleven sampled points per member; the moment extremes are exact, but the largest vertical displacement is the largest sampled value.
- For a symmetric bent under gravity alone the drift is only the spreading of the tiers, and its ratio means little.
- maxMoment and minMoment read blank when no member has a moment of that sign.
Restrictions and non-computing states
- E is between 10 and 100,000 ksi, or 70 and 700,000 MPa.
- The density is above 0 and at most 1,600 lb/ft³ or 25,000 kg/m³; including the self-weight needs a density.
- At most 400 nodes, 400 members and 12 sections; node IDs and member IDs are unique, ignoring letter case.
- Node coordinates are from -5,000 to 5,000 ft (-1,500 to 1,500 m), and no member has zero length.
- The typical bent is a group of the drawing with at most 16 nodes, 24 members and 4 tiers, in one plane across the rack, with level beams.
- A nodal load is at most 1,000 kip (4,500 kN) in force and 10,000 kip-ft (13,500 kN-m) in moment, either way; a member load is at most 50 kip/ft (750 kN/m) either way. A load names a node or member of the typical bent.
Errors and warnings
Each NOT VALID status names the first input to fix, for example "no column or beam has the group ID BENT-9", "the typical bent has more than 24 members or 16 nodes", "bent member load T1 names member M40, which is not in the typical bent" or "the typical bent is unstable".
References
The takeoff measures each member from its end nodes and weighs it from its section's area and the density you give. The typical bent is analysed by linear elastic 2D frame theory: the direct stiffness method for plane frames with rigid joints, prismatic Euler-Bernoulli members and finite axial stiffness, with uniform member loads entered as fixed-end forces. The bent's connectivity is checked with the matrix-tree theorem. Section properties come from idealized sharp-corner outlines by component rectangles; no shape table is used.
Sources and further reading
- The direct stiffness method for plane frames, including member stiffness in local and global axes, fixed-end forces and member end forces: A. Kassimali, Matrix Analysis of Structures, 3rd edition, Cengage Learning, 2022, chapter 6, Plane Frames. Publisher page
- The stiffness analysis of frames and the solution of the global equations: W. McGuire, R. H. Gallagher and R. D. Ziemian, Matrix Structural Analysis, 2nd edition, 2000. Free edition from Bucknell University
- The matrix-tree theorem, used to check that the bent's members form one connected frame: E. W. Weisstein, "Matrix Tree Theorem", MathWorld, Wolfram Research. MathWorld
- Areas of composite sections, centroids, second moments of area and the parallel-axis theorem: B. J. Goodno and J. M. Gere, Mechanics of Materials, 9th edition, Cengage Learning, 2018, appendix D, Review of Centroids and Moments of Inertia. Publisher page
- Conversion factors for the pound, the short ton, the kilogram and the metric ton used in the takeoff weights: A. Thompson and B. N. Taylor, Guide for the Use of the International System of Units (SI), NIST Special Publication 811, 2008 edition, appendix B, Conversion Factors. NIST
No table, chart or text from any of these publications is reproduced, and none of their authors or publishers has reviewed or endorses this calculator.
Its results were checked against two independent methods: closed-form textbook solutions for pinned and fixed portals of equal sections under gravity and sway loads, and an independent exact direct stiffness solution of each test bent, with an independent takeoff of each test rack.
The results are not a rack design. Applicable design codes and a qualified engineer govern real structures.
Found a problem, or have an idea?
Tell us if a result looks wrong, a label is unclear, or something is missing. We read every message.