Electric To Heat Pump Water Heater Calculator

Compares keeping your electric water heater with replacing it with a heat pump water heater: yearly electricity use and running cost from your own figure, ENERGY STAR and DOE data, simple and discounted payback, and the total and present-value cost of keeping, replacing now or replacing when the old tank fails. Estimates for planning, not financial advice.

Last updated

How to Use the Electric to Heat Pump Water Heater Calculator: Keep the Tank or Switch?

Plays from YouTube. Close the video to keep working on your drawing.

Calculator overview

Inputs and outputs

This summary comes from the calculator's published input and output contract.

Inputs

H05 Old Manual Metric (required) Conditional
About this input

Its UEF (on labels from 2017), its EF (older labels), or the yearly electricity figure on its EnergyGuide label.

Default UEF (label from 2017) Allowed UEF (label from 2017), EF (older label), Yearly energy on the EnergyGuide label
H05 Old Manual Value (required) Conditional
About this input

A UEF or EF from 0.40 to 5.00, or the label's yearly electricity in kWh (up to 10,000).

Default 0.92 Range 0.01 to 10000
H05 Old Remaining Life
When omitted Blank
About this input

Fills the replace-at-end-of-life comparison. Blank skips it.

Unit years Default Not set Range 0 to 30
H05 Old Manual Label Draw (required) Conditional
About this input

The DOE draw pattern behind the label figure, or Older label (64.3 gal/day). Unknown uses the label figure as it stands.

Default Unknown Allowed Very small, Low, Medium, High, Older label (64.3 gal/day), Unknown
H05 Old Baseline KWh (required) Conditional
About this input

The electricity the old tank uses a year, from a meter or your bills (water heating only), up to 15,000 kWh.

Unit kWh/yr Default 3500 Range 1 to 15000
H05 Old Baseline UEF Conditional
When omitted Blank
About this input

The old tank's Uniform Energy Factor, 0.40 to 5.00. Blank uses the current federal minimum for a 50-gallon electric tank (0.9207).

Default Not set Range 0.4 to 5
H05 Old Maintenance
When omitted Blank
About this input

Service or repairs you expect each year if you keep the old tank.

Unit $/yr Default Not set Range 0 to 5000
H05 Old Source (required)
About this input

Enter the electricity it uses a year for hot water; or, if you do not know it, the year it was made; or its rating or the yearly figure from its EnergyGuide label.

Default I know its yearly electricity use (bills or a meter) Allowed I know its yearly electricity use (bills or a meter), Model not found: pick year made, Manual entry
H05 Sales Tax Rate
When omitted Blank
About this input

Applied to the unit price only.

Default Not set Range 0 to 0.15
H05 Setpoint F
When omitted Blank
About this input

The temperature the heater keeps the water at. Blank uses the DOE test value, 125 F.

Unit F Default Not set Range 100 to 160
H05 State (required)
About this input

USPS state code, or US for the national average. The default is the state's average residential price, not your tariff.

Default US Allowed AK, AL, AR, AZ, CA, CO, CT, DC, DE, FL, GA, HI, IA, ID, IL, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, RI, SC, SD, TN, TX, UT, VA, VT, WA, WI, WV, WY, US
H05 Rate Growth
When omitted Blank
About this input

Blank means a flat price.

Default Not set Range -0.1 to 0.15
H05 Old Vintage (required) Conditional
About this input

The year it was made. The calculator uses the federal minimum efficiency for that year and tank size; your tank may be more efficient.

Default Made in 2010 Allowed Made in 1990, Made in 1991, Made in 1992, Made in 1993, Made in 1994, Made in 1995, Made in 1996, Made in 1997, Made in 1998, Made in 1999, Made in 2000, Made in 2001, Made in 2002, Made in 2003, Made in 2004, Made in 2005, Made in 2006, Made in 2007, Made in 2008, Made in 2009, Made in 2010, Made in 2011, Made in 2012, Made in 2013, Made in 2014, Made in 2015, Made in 2016, Made in 2017, Made in 2018, Made in 2019, Made in 2020, Made in 2021, Made in 2022, Made in 2023, Made in 2024, Made in 2025, Made in 2026
H05 Old Vintage Volume Gal (required) Conditional
About this input

The rated volume on the tank's label, 20 to 120 gallons. The federal minimum depends on it.

Unit gal Default 50 Range 20 to 120
H05 Permit
When omitted Blank
About this input

Permit fee, if your area requires one.

Unit $ Default Not set Range 0 to 2000
H05 Horizon Years (required)
About this input

The comparison period, 1 to 30 whole years.

Unit years Default 10 Range 1 to 30
H05 Hot Water Gal Per Day (required) Conditional
About this input

Gallons of hot water a day (not read when you enter the old tank's yearly electricity: the calculator works it out). DOE rates water heaters at 10, 38, 55 and 84 gallons a day.

Unit gal/day Default 55 Range 0 to 200
H05 Incentives
When omitted Blank
About this input

Only rebates and credits you have confirmed you qualify for, such as a utility rebate or the federal 25C credit. The calculator never assumes one.

Unit $ Default Not set Range 0 to 5000
H05 Electricity Rate Override
When omitted Blank
About this input

From your bill. Overrides the state average.

Unit $/kWh Default Not set Range 0.01 to 2
H05 Discount Rate
When omitted Blank
About this input

Blank means no discounting.

Default Not set Range 0 to 0.2
H05 Disposal
When omitted Blank
About this input

Haul-away charge, if any.

Unit $ Default Not set Range 0 to 1000
H05 Electrical Work
When omitted Blank
About this input

A new circuit or panel work, if the heat pump needs it.

Unit $ Default Not set Range 0 to 10000
H05 Inlet Temp F
When omitted Blank
About this input

The temperature of the cold water entering the heater. Blank uses the DOE test value, 58 F.

Unit F Default Not set Range 35 to 80
H05 New Model HP (required) Conditional
About this input

Brand and model number as listed by ENERGY STAR today. In a model number, * stands for any character and # for any digit.

Default Rheem | XE50T10HM00U0 Allowed 1HVAC | ACIQ-50G-HP-WH, 1HVAC | ACIQ-80G-HP-WH, A. O. Smith | CAHP-40 2**, A. O. Smith | CAHP-50 2**, A. O. Smith | CAHP-66 2**, A. O. Smith | CAHP-80 2**, A. O. Smith | FPTU-50 1**, A. O. Smith | FPTU-66 1**, A. O. Smith | FPTU-80 1**, A. O. Smith | HP1050H45DV 1**, and 537 more (the calculator lists them all)
H05 New Price (required)
About this input

The price of the unit itself; installation and other work are entered separately. The calculator never looks up a price. Illustrative price for this example, not a quote or a current price. Prices vary: check current prices online or enter your own.

Unit $ Default 1800 Range 1 to 20000
H05 New Source (required)
About this input

Pick a currently certified ENERGY STAR heat pump water heater, or type its UEF.

Default Model from current ENERGY STAR list Allowed Model from current ENERGY STAR list, Manual entry
H05 New Manual Value (required) Conditional
About this input

The Uniform Energy Factor on the heat pump's label or specification sheet, 0.40 to 5.00.

Default 3.5 Range 0.4 to 5
H05 Installation
When omitted Blank
About this input

Labour to install the heat pump, including a condensate drain, from your quote.

Unit $ Default Not set Range 0 to 10000
H05 New Expected Life
When omitted Blank
About this input

Used only for the value left in the heat pump at the end of the period (straight line). Blank uses the DOE lifetime, 15 years.

Unit years Default Not set Range 1 to 40
H05 New Maintenance
When omitted Blank
About this input

Service you expect each year for the heat pump, such as filter cleaning.

Unit $/yr Default Not set Range 0 to 5000

Outputs

H05 PV Keep
About this output

Present value of keeping the old tank at the discount rate.

Unit $
H05 Old Model Card
About this output

Old electric tank: The unit as the calculator reads it: type, rating and the record it came from.

No unit declared
H05 PV Replace Now
About this output

Present value of replacing now at the discount rate.

Unit $
H05 PV Replace End Of Life
About this output

Present value of replacing when the old tank fails. Blank when not evaluated.

Unit $
H05 Old Metric Used
About this output

Old electric tank: The UEF used for the unit (an EF used as the UEF, a UEF implied by a label, or the baseline tank's UEF). Blank when a label figure is used as it stands.

Unit UEF
H05 Old Annual Total Cost
About this output

Old electric tank: Electricity and upkeep in year 1.

Unit $/yr
H05 Old Annual KWh
About this output

Old electric tank: Electricity a year at your hot water use.

Unit kWh/yr
H05 Old Baseline UEF Used
About this output

On the yearly-electricity route, the old tank's UEF used: yours, or the current federal minimum. Blank on other routes.

Unit UEF
H05 Old Baseline UEF Note
About this output

Which old-tank UEF the yearly-electricity route uses: yours, or the current federal minimum for a 50-gallon tank.

No unit declared
H05 Replace Now Verdict
About this output

The comparison of replacing now with keeping, in words.

No unit declared
H05 Total Replace End Of Life
About this output

Keep the old tank until it fails, then buy the heat pump at today's price. Blank when no remaining life below the period is given.

Unit $
H05 Total Keep
About this output

Running cost of keeping the old tank over the years compared, without discounting.

Unit $
Model Status
About this output

OK, CHECK with a reason to read, or NOT VALID with what to fix.

No unit declared
H05 Total Replace Now
About this output

Net initial cost plus the heat pump's running cost over the years compared, less the value left at the end, without discounting.

Unit $
H05 Status Code
About this output

The deciding reason of the status line as a short code, OK when nothing applies.

No unit declared
H05 Sensitivity Savings
About this output

Money saved in year 1 for 10 to 120 gallons of hot water a day (rows) and 50% to 150% of the electricity price used (columns).

No unit declared
H05 Self Check
About this output

Whether the model's internal consistency checks hold.

No unit declared
H05 Simple Payback Years
About this output

Net initial cost divided by the money saved in year 1. Blank when nothing is saved or the price is missing.

Unit years
H05 Simple Payback Text
About this output

The simple payback in words: the years, no payback, or a missing price.

No unit declared
H05 Electricity Rate Note
About this output

Where the electricity price comes from: the EIA state average and its year, or your own price.

No unit declared
H05 Discounted Payback Year
About this output

The first year in which the cumulative discounted net benefit of replacing now reaches zero. Blank when it does not within the years compared.

Unit year
H05 End Of Life Verdict
About this output

The comparison of replacing now with waiting until the old tank fails, in words.

No unit declared
H05 Electricity Rate Used
About this output

The electricity price in the sums: your own, or the state average.

Unit $/kWh
H05 Discounted Payback Text
About this output

The discounted payback in words.

No unit declared
H05 Annual Savings USD
About this output

Old minus new running cost in year 1; negative means the heat pump costs more to run.

Unit $/yr
H05 Annual Energy Savings KWh
About this output

Old minus new electricity a year.

Unit kWh/yr
H05 Data Vintage Note
About this output

The sources and their dates.

No unit declared
H05 Cash Flow
About this output

Year-by-year costs of keeping, replacing now and replacing at end of life, the net benefit of replacing now, and its cumulative and discounted values. Rows past the years compared are blank.

No unit declared
H05 Implied Gal Per Day
About this output

The hot water a day in the sums: yours, or the amount your old tank's yearly electricity implies.

Unit gal/day
H05 New Model Card
About this output

Heat pump: The unit as the calculator reads it: type, rating and the record it came from.

No unit declared
H05 New Metric Used
About this output

Heat pump: The UEF used for the unit (an EF used as the UEF, a UEF implied by a label, or the baseline tank's UEF). Blank when a label figure is used as it stands.

Unit UEF
H05 Old Annual Energy Cost
About this output

Old electric tank: Electricity cost in year 1.

Unit $/yr
H05 NPV Replace Now
About this output

Present value of keeping minus that of replacing now; positive means replacing now costs less.

Unit $
H05 New Expected Life Used
About this output

The heat pump's life used for the value left at the end: yours, or the DOE lifetime.

Unit years
H05 New Annual Energy Cost
About this output

Heat pump: Electricity cost in year 1.

Unit $/yr
H05 Net Initial Cost
About this output

Price, sales tax, installation, electrical work, permit and disposal, less incentives.

Unit $
H05 New Annual Total Cost
About this output

Heat pump: Electricity and upkeep in year 1.

Unit $/yr
H05 New Annual KWh
About this output

Heat pump: Electricity a year at your hot water use.

Unit kWh/yr
This page is provided by LogicCommons for informational purposes only. Results are model outputs computed from the inputs you supply and are not financial, investment, tax, accounting, or legal advice, and no advisory relationship is created. Verify all inputs and results independently before relying on them in any decision.

LogicCommons is in beta. If a result, label, or reference looks wrong, tell us here; we read every message.

What it is

This calculator weighs keeping an electric resistance water heater against replacing it with a heat-pump water heater. Describe the old tank by the electricity it uses a year, by the year it was made and its size, or from its efficiency rating or EnergyGuide label. Then pick the heat pump from the ENERGY STAR list and enter what you pay for electricity and what the switch costs installed, including any electrical work. It works out each heater's yearly electricity and cost, the yearly saving, the net cost of the heat pump, the simple and discounted payback, and the cost over the years you choose of keeping the old tank, replacing it now, or replacing it when it wears out.

Model figures come from federal sources only: the ENERGY STAR certified list published by the EPA, and the DOE test procedure and efficiency standards. Default electricity prices come from the EIA. You set the price of the heat pump; the opening example carries an illustrative one.

Methodology

Purpose and model boundary

This calculator compares keeping an electric resistance water heater with replacing it with a heat-pump water heater. It works out the heat your household's hot water needs each year, either from your hot water use or from the electricity your old tank uses now, divides it by each heater's DOE efficiency rating to get the electricity each uses, prices that at your electricity rate, and sets the yearly saving against what the heat pump costs installed. Over the years you choose, it compares keeping the old tank, replacing it now and, when you say how many years the old tank has left, replacing it when it wears out.

Every figure on this page is computed by the spreadsheet; the page adds nothing to it. The model covers running cost and purchase cost only, for electricity alone. It does not judge recovery speed, hot-water capacity at peak use, noise or reliability, and it does not price financing, warranties or your own time.

Inputs and units

  • The old electric tank, described in one of three ways:
    • the electricity it uses a year for hot water, from your bills or a meter (the default), with its efficiency if you know it; blank uses the current federal minimum for a 50-gallon tank;
    • the year it was made and its tank size in gallons: the calculator then uses the federal minimum efficiency for that year;
    • manual entry: its UEF, its EF from the older DOE test, or the yearly electricity on its EnergyGuide label with the label's draw pattern (Very small, Low, Medium, High, the older label's 64.3 gallons a day, or Unknown, where it starts).
  • The new heat-pump water heater: a model from the current ENERGY STAR list of heat-pump water heaters, or its UEF by hand, and its price, more than $0 and at most $20,000. Each entry reads "Brand | Model number", exactly as ENERGY STAR lists it.
  • Hot water use: gallons a day, 0 to 200, read when the old tank is described by its year made or its rating (the default is 55, the DOE's medium draw pattern); optionally your setpoint (blank uses the DOE's 125 °F) and the temperature of the incoming cold water (blank uses 58 °F). With the yearly-use route the calculator works out your hot water use from your electricity instead.
  • Electricity price, optional: the state sets the default; your own price in dollars per kWh overrides it.
  • Purchase and upkeep: installation, electrical work (often a new circuit), permit, removal and disposal of the old tank, sales tax on the price, verified rebates and tax credits, and yearly upkeep for each. Each is optional and counts as zero when left blank.
  • The comparison: the years to compare (1 to 30), the yearly change in the electricity price, the discount rate, and, optionally, the years the old tank has left and the expected life of the heat pump.

Energy is in kWh, hot water in US gallons a day, temperatures in °F and money in dollars. A water heater's rating, the uniform energy factor (UEF), is the heat delivered in hot water per unit of electricity used: higher is better.

Governing relationships

Heat needed. The yearly heat in your hot water is gallons a day × 365 × 8.24 pounds per gallon × 1 Btu per pound per °F × the temperature rise, the setpoint less the inlet temperature (67 °F at the DOE's 125 °F and 58 °F).

Electricity used. Each heater's yearly electricity is that heat ÷ its UEF ÷ 3,412.14 Btu per kWh. Heat-pump water heaters on the current list are rated from 2.52 to 4.5; a resistance tank turns each kWh into less than one kWh of hot water, so at the same hot water use a heat pump always uses less electricity.

Starting from your yearly electricity. When you enter the electricity your old tank uses a year, the calculator works out the heat it delivers, that use × 3,412.14 Btu per kWh × the old tank's UEF, and the heat pump's electricity is your use × the old UEF ÷ the new UEF. Your hot water use is then implied, and shown so that you can check it against the DOE's patterns; outside 10 to 120 gallons a day, the status says so. Left blank, the old tank's UEF is the current federal minimum for a 50-gallon electric tank, 0.9207, and a note says so.

What the rating includes. A UEF already includes a tank's standby losses, so they are not added again; the calculator scales them with your hot water use, which is the method's limit.

Older ratings and labels. A tank rated by EF, the DOE's older test (135 °F outlet), is used as if its EF were a UEF, without conversion, and the status says so. A yearly figure from an EnergyGuide label is scaled to your use: the label assumes the DOE draw pattern it names, or 64.3 gallons a day at a 77 °F rise for an older label; with the pattern unknown, the label figure is used as it stands.

A tank described by the year it was made. No DOE figures for typical tanks by year were available, so the calculator uses the federal minimum efficiency for that year and tank size: your tank may be more efficient, so the saving may be overstated, and the status says so.

  • The minimum falls with tank size: 0.95 − 0.00132 × the volume for an electric tank made from 1990, 0.93 − 0.00132 × V from April 15, 1991, 0.97 − 0.00132 × V from 2004; from April 16, 2015 it depends on whether the tank holds more than 55 gallons. The calculator uses those 2015 limits for every tank made since, as the UEF: DOE's later UEF table restates the same standards.
  • Above 55 gallons, an electric tank made after April 16, 2015 must meet a heat-pump level of efficiency, so a large resistance tank of that age is unusual.

Yearly cost. For each heater, the yearly utility cost is its kWh times the electricity price. Adding yearly upkeep gives its yearly cost, and the yearly saving is the old tank's yearly cost less the heat pump's.

Purchase cost. The capital cost is the price × (1 + sales tax rate) + installation + electrical work + permit − rebates and credits. The net initial cost adds removal and disposal; a used tank has no resale value.

Payback. Simple payback is the net initial cost ÷ the first year's saving, when the saving is positive; otherwise there is no payback. Discounted payback is the first year in which the cumulative discounted net benefit of replacing now reaches zero within the years compared.

The three paths over the years compared. The electricity price changes each year by the rate you enter; upkeep stays flat; costs fall at the end of each year and are discounted at your rate.

  • Keep: the old tank's yearly cost every year.
  • Replace now: the net initial cost today, then the heat pump's yearly cost, less the value left in it at the end.
  • Replace at end of life (when you enter the years the old tank has left and they are fewer than the years compared): the old tank's yearly cost until it fails, then the capital cost and disposal in that year at today's price, then the heat pump's yearly cost, less the value left in it at the end.

The value left in the heat pump at the end is its capital cost × the share of its expected life still remaining, on a straight line. Enter its expected life, or leave it blank to use the DOE's typical lifetime for a water heater, 15 years. The net present value of replacing now is the present cost of keeping less the present cost of replacing now: positive means replacing now costs less.

Calculation sequence

The spreadsheet first finds the old tank's yearly use or rating and the heat pump's rating from the list, the year table or your entries, and checks the inputs. It then works out the yearly heat your hot water needs, divides it by each heater's rating to get its electricity, and from that computes the yearly costs and the saving. The purchase cost, the paybacks, the present values of the three paths and the year-by-year cash flow follow. The sensitivity table uses the same per-gallon figures, so it cannot disagree with the main result. A block of consistency checks, including that the discounted cash flow reaches the same net present value as the closed-form formula, runs before the status is returned.

Outputs and interpretation

The headline is the yearly saving from replacing the old tank, with the simple payback and the net present value of replacing now. For each heater the results give its yearly kWh and its yearly energy and total cost, with the electricity price actually used and a note on where it came from; on the yearly-use route, the hot water use your figures imply. The decision results give the net initial cost, the discounted payback year, the total and present cost of keeping, of replacing now and of replacing at end of life, and a plain verdict on each.

The cash-flow table shows each year from 0 to the years compared: the cost of each path, the net benefit of replacing now, and its cumulative, discounted and cumulative discounted values. The sensitivity table shows the yearly saving at 10, 20, 38, 55, 70, 84, 100 and 120 gallons of hot water a day, and at 0.50 to 1.50 times the electricity price used.

A model card beside the heat-pump pick shows its type (240 V or 120 V integrated, or split), tank size, draw pattern, first-hour rating, UEF and the year it became available.

The first chart, “Cumulative net benefit of replacing now, by year”, shows Undiscounted and Discounted by year. The second chart, “Cost over the years compared”, shows Total and Present value by option. The third chart, “Running cost in year 1”, shows Energy and Upkeep by unit, stacked.

Validation and status logic

The workbook returns one status, chosen in this order: NOT VALID, then CHECK, then OK.

  • NOT VALID names the first problem: a source that is not one of its options; a heat-pump model that is not in the list; no year made, or no federal limit for that year and volume; a yearly use missing or not above 0 and at most 15,000 kWh, a UEF or EF outside 0.40 to 5.00, or a label figure not above 0 and at most 10,000 kWh; a label draw pattern that is not one of its options; a tank size missing or outside 20 to 120 gallons; an upkeep figure outside its range; hot water a day outside 0 to 200 gallons when it is read, or a setpoint or inlet temperature out of range; no electricity price, or your own price outside $0.01 to $2.00 per kWh; a price for the heat pump that is missing, not above $0 or above $20,000; another money or rate input outside its range; or years to compare, years left or expected life that are not whole numbers in range. NOT VALID is a refusal, not a numeric answer: every figure reads zero and is withheld.
  • CHECK accompanies a computed result that needs the stated review: the federal minimum efficiency used for a tank described by its year made, so it may be more efficient and the saving may be overstated; an old tank rated by EF, the older DOE test, used without conversion; a label figure whose draw pattern is unknown, so it is used without scaling to your hot water use; a yearly use that implies hot water outside 10 to 120 gallons a day; zero hot water a day; a heat pump that does not cost less to run than the old tank, so there is no payback; or an old tank with fewer years left than the years compared, so the end-of-life path is the realistic one.
  • OK otherwise.

Assumptions and limitations

  • There is no list of electric resistance tanks. ENERGY STAR does not certify them, so the old tank is described by its yearly electricity, its year made or its own rating.
  • The federal minimum is a floor, not a measurement. A tank described by its year made, or whose efficiency is left blank on the yearly-use route, may be more efficient, so the saving may be overstated.
  • Your yearly electricity must be for hot water only. A figure from your bills that includes other uses overstates the saving; check the hot water use it implies.
  • Heat pumps in cold spaces are not modelled. A heat-pump water heater is rated at 67.5 °F; in a cold or unconditioned space its compressor does less and its backup elements more, and it cools the room it stands in. The calculator uses the rating as it stands.
  • The default electricity price is an average: the EIA's annual average residential price for the state, not your tariff. Enter your own price from your bill for a better answer.
  • The future purchase in the end-of-life path is priced at today's price. There is no loan and no depreciation other than the value left in the heat pump at the end.

Data and vintage

The heat-pump list, the year table and the default electricity prices are reviewed reference tables inside the workbook, refreshed from their federal publishers; their version is shown in the result details.

  • Heat-pump models: the heat-pump water heaters in the ENERGY STAR certified water heaters dataset (EPA), 717 rows of which 613 are for the US market, downloaded 2026-10-28.
  • Year made: the federal minimum efficiency for electric water heaters by date of manufacture and tank size, 10 CFR 430.32(d), from the 1990 standard on.
  • Default electricity prices: EIA 2025 annual average residential electricity prices by state (Form EIA-861).

Worked examples and prices

Prices are not part of the reference data: the price of the new unit is an input you set. The opening example and the five worked examples each use an illustrative price for the new unit, so that the example computes, and each says so: “Illustrative price for this example, not a quote or a current price. Prices vary: check current prices online or enter your own.”

Restrictions and non-computing states

The calculator enforces its numeric and choice limits before it accepts a result. A heat-pump model that is not in the list, an old tank with no yearly use, year or rating, and a missing price for the heat pump are refused by the workbook.

Errors and warnings

A request rejected by the page's input limits is not a computed result. A transport or service failure, a timeout or a cancelled run cannot establish a fresh workbook answer, and the last result stays on the page marked as out of date. Check your unit's label or specification sheet and your own bills before relying on a result for a purchase.

References

Sources and further reading

The calculator reads its model lists, its year-made limits and its default utility prices from reviewed reference tables inside the workbook, by record, with their version shown in the result details. Every table comes from a US federal source. The sources below publish the data and the rules the model applies. They do not endorse this calculator.

This is an educational estimate of running and purchase costs for the units and prices you enter, not a product recommendation or a quote. The ENERGY STAR lists show each model's rated use under the DOE test procedure, not your unit's measured use; check your own bills before acting on a result.

Frequently asked questions

Will a heat-pump water heater always save me money?
On electricity, yes: at the same hot water use a heat pump uses far less than a resistance tank. Whether the switch pays back depends on its installed cost, your hot water use and your electricity price; at low use and a cheap rate it may not pay back within the years you compare, and the calculator shows that plainly.
I don't know my tank's model. What should I enter?
ENERGY STAR never lists resistance tanks, so the calculator does not ask for a model. Enter the electricity it uses a year for hot water if you know it, or the year it was made and its size, or its UEF or EF from the nameplate.
How do I find my water heater's yearly electricity?
From a separate meter or circuit monitor if you have one, or by estimating the water-heating part of your bill. The calculator shows the hot water use your figure implies; if it is outside 10 to 120 gallons a day, the status asks you to check that the figure is for water heating only.
Does it matter where the heat pump goes?
Yes, but the calculator does not model it. The rating assumes a 67.5 °F room; in a cold garage or basement a heat pump works less well, and it cools the space it stands in. Treat the result as the rated case.
Where does the heat pump's price come from, and what about tax credits?
You set the price. Prices are not part of the calculator's reference data; the opening example and the worked examples carry an illustrative price for their heat pump only so that they compute: it is not a quote or a current price. Prices vary, so check current prices online or enter your own. Enter installation, electrical work and permits separately, and enter a rebate or tax credit only once you have confirmed you qualify: the calculator never assumes one.
Is the electricity price my actual rate?
No. The default is the EIA's 2025 average residential electricity price for your state. Enter the price from your own bill for a better answer.
Results are informational and not professional advice. See our Terms of Use. Powered by SpreadsheetWeb · About · Privacy · Terms