Calculator overview
Inputs and outputs
This summary comes from the calculator's published input and output contract.
Inputs
- A11 Old Maintenance
-
When omitted Blank
Unit $/yr Default Not set Range 0 to 5000
About this input
Repairs or service you expect each year if you keep the old fans.
- A11 Old Manual Standby W Conditional
-
When omitted Blank
Unit W Default Not set Range 0 to 10
About this input
Power drawn while the fan is off but powered (remote receivers). Blank counts none.
- A11 Old Manual Watts (required) Conditional
-
Unit W Default 75 Range 0.1 to 500
About this input
The fan's power in watts at the speed you use most, from its label or manual (fan only, without the light).
- A11 New Source (required)
-
Default Model from current ENERGY STAR list Allowed Model from current ENERGY STAR list, Manual entry
About this input
Pick a currently certified ENERGY STAR model, or type its power in watts.
- A11 Old Curr Model (required) Conditional
-
Default AERATRON | AE+2WI43*** Allowed AERATRON | AE+2WI43***, AERATRON | AE+2WI43L***, AERATRON | AE+2WI50***, AERATRON | AE+2WI50L***, AERATRON | AE+2WI60***, AERATRON | AE+2WI60L***, AERATRON | AE+3WI43***, AERATRON | AE+3WI43L***, AERATRON | AE+3WI50***, AERATRON | AE+3WI50L***, and 1,315 more (the calculator lists them all)
About this input
For an old fan that is still ENERGY STAR certified: brand and model number as listed today.
- A11 Old Hist Model (required) Conditional
-
Default Hunter | 53358 Allowed AERATRON | AE2-43*, AERATRON | AE2-50*, AERATRON | AE2-60*, AERATRON | AE3-43-LED-*, AERATRON | AE3-43*, AERATRON | AE3-60*, Big Air | ICF72, Big Air | ICF96, Biltmore | C330, Biltmore | C575, and 378 more (the calculator lists them all)
About this input
Brand and model number as listed by ENERGY STAR. In a model number, * stands for any character; a blade span in brackets separates listings of the same model.
- A11 Old Remaining Life
-
When omitted Blank
Unit years Default Not set Range 0 to 30
About this input
Fills the replace-at-end-of-life comparison. Blank skips it.
- A11 Sales Tax Rate
-
When omitted Blank
Default Not set Range 0 to 0.15
About this input
Applied to the fans' price only.
- A11 Speed (required)
-
Default DOE test average Allowed Low, High, DOE test average
About this input
Low, High, or the DOE test average (3.0 hours low and 3.4 hours high of 6.4). A listed fan without a published low-speed figure needs High.
- A11 State (required)
-
Default US Allowed AK, AL, AR, AZ, CA, CO, CT, DC, DE, FL, GA, HI, IA, ID, IL, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, RI, SC, SD, TN, TX, UT, VA, VT, WA, WI, WV, WY, US
About this input
USPS state code, or US for the national average. The default is the state's average residential price, not your tariff.
- A11 Old Sale Value
-
When omitted Blank
Unit $ Default Not set Range 0 to 5000
About this input
Money you receive for the old fans if you replace them now.
- A11 Old Source (required)
-
Default Model from historic ENERGY STAR list Allowed Model from historic ENERGY STAR list, Model from current ENERGY STAR list, Manual entry
About this input
Pick the model from the historic ENERGY STAR list (Version 3, 2011-2018) or the current list; if it is not listed, type its power in watts.
- A11 Rate Growth
-
When omitted Blank
Default Not set Range -0.1 to 0.15
About this input
Blank means flat prices.
- A11 New Price (required)
-
Unit $ Default 200 Range 1 to 5000
About this input
The price of one fan; the calculator multiplies it by the number of fans. The calculator never looks up a price. Illustrative price for this example, not a quote or a current price. Prices vary: check current prices online or enter your own.
- A11 Fan Count (required)
-
Unit fans Default 1 Range 1 to 20
About this input
How many identical fans you are comparing, 1 to 20.
- A11 Horizon Years (required)
-
Unit years Default 10 Range 1 to 30
About this input
The comparison period, 1 to 30 whole years.
- A11 Hours Per Day (required)
-
Unit hours/day Default 6.4 Range 0 to 24
About this input
The default, 6.4, is the DOE test procedure's figure (10 CFR 430 Subpart B Appendix U: 3.4 hours at high speed and 3.0 at low).
- A11 Discount Rate
-
When omitted Blank
Default Not set Range 0 to 0.2
About this input
Blank means no discounting.
- A11 Disposal
-
When omitted Blank
Unit $ Default Not set Range 0 to 1000
About this input
Removal charge, if any.
- A11 Electricity Rate Override
-
When omitted Blank
Unit $/kWh Default Not set Range 0.01 to 2
About this input
From your bill. Overrides the state average.
- A11 Incentives
-
When omitted Blank
Unit $ Default Not set Range 0 to 5000
About this input
Only incentives you have confirmed you qualify for.
- A11 New Manual Standby W Conditional
-
When omitted Blank
Unit W Default Not set Range 0 to 10
About this input
Power drawn while the new fan is off but powered. Blank counts none.
- A11 New Manual Watts (required) Conditional
-
Unit W Default 30 Range 0.1 to 500
About this input
The new fan's power in watts at the speed you will use most.
- A11 New Model (required) Conditional
-
Default Hunter | 52874 Allowed AERATRON | AE+2WI43***, AERATRON | AE+2WI43L***, AERATRON | AE+2WI50***, AERATRON | AE+2WI50L***, AERATRON | AE+2WI60***, AERATRON | AE+2WI60L***, AERATRON | AE+3WI43***, AERATRON | AE+3WI43L***, AERATRON | AE+3WI50***, AERATRON | AE+3WI50L***, and 1,315 more (the calculator lists them all)
About this input
Brand and model number as listed by ENERGY STAR today. The model card shows its watts at low and high speed and in standby.
- A11 Installation
-
When omitted Blank
Unit $ Default Not set Range 0 to 5000
About this input
Your quote for all the fans. Not included unless entered.
- A11 New Expected Life
-
When omitted Blank
Unit years Default Not set Range 1 to 40
About this input
Used for the value left in the new fans at the end of the period (straight line). Blank counts no value left: no federal lifetime for ceiling fans was found.
- A11 New Maintenance
-
When omitted Blank
Unit $/yr Default Not set Range 0 to 5000
About this input
Service you expect each year for the new fans.
Outputs
- A11 PV Replace End Of Life
-
Unit $
About this output
Present value of replacing when the old fans fail. Blank when not evaluated.
- A11 PV Keep
-
Unit $
About this output
Present value of keeping the old fans at the discount rate.
- A11 Replace Now Verdict
-
No unit declared
About this output
The comparison of replacing now with keeping, in words.
- A11 PV Replace Now
-
Unit $
About this output
Present value of replacing now at the discount rate.
- A11 Old Rated Figure
-
Unit W
About this output
Old unit: The fan's power at the speed chosen (or the DOE test average), or your figure.
- A11 Old Annual Total Cost
-
Unit $/yr
About this output
Old unit: Electricity and upkeep in year 1.
- A11 Old Annual KWh
-
Unit kWh/yr
About this output
Old unit: Fans x (watts x hours + standby x the other hours of the day) x 365 / 1,000.
- A11 Old Model Card
-
No unit declared
About this output
Old unit: The fan as the calculator reads it: product type, year, watts at low and high speed and in standby, and the record it came from.
- A11 Old Annual Upkeep
-
Unit $/yr
About this output
Old unit: The yearly upkeep you entered.
- A11 Total Replace End Of Life
-
Unit $
About this output
Keep the old fans until they fail, then buy the new ones at today's price. Blank when no remaining life below the period is given.
- A11 Total Keep
-
Unit $
About this output
Running cost of keeping the old fans over the years compared, without discounting.
- Model Status
-
No unit declared
About this output
OK, CHECK with a reason to read, or NOT VALID with what to fix.
- A11 Total Replace Now
-
Unit $
About this output
Net initial cost plus the new fans' running cost over the years compared, less the value left at the end, without discounting.
- A11 Status Code
-
No unit declared
About this output
The deciding reason of the status line as a short code, OK when nothing applies.
- A11 Sensitivity Savings
-
No unit declared
About this output
Money saved in year 1 at 1 to 24 hours a day (rows) and 50% to 150% of the electricity price used (columns).
- A11 Self Check
-
No unit declared
About this output
Whether the model's internal consistency checks hold.
- A11 Simple Payback Years
-
Unit years
About this output
Net initial cost divided by the money saved in year 1. Blank when nothing is saved or the price is missing.
- A11 Simple Payback Text
-
No unit declared
About this output
The simple payback in words: the years, no payback, or a missing price.
- A11 Electricity Rate Note
-
No unit declared
About this output
Where the electricity price comes from: the EIA state average and its year, or your own price.
- A11 Discounted Payback Year
-
Unit year
About this output
The first year in which the cumulative discounted net benefit of replacing now reaches zero. Blank when it does not within the years compared.
- A11 End Of Life Verdict
-
No unit declared
About this output
The comparison of replacing now with waiting until the old fans fail, in words.
- A11 Electricity Rate Used
-
Unit $/kWh
About this output
The electricity price in the sums: your own, or the state average.
- A11 Discounted Payback Text
-
No unit declared
About this output
The discounted payback in words.
- A11 Annual Savings USD
-
Unit $/yr
About this output
Old minus new running cost in year 1; negative means the new fans cost more to run.
- A11 Annual Energy Savings KWh
-
Unit kWh/yr
About this output
Old minus new electricity a year; negative means the new fans use more.
- A11 Data Vintage Note
-
No unit declared
About this output
The sources and their dates.
- A11 Cash Flow
-
No unit declared
About this output
Year-by-year costs of keeping, replacing now and replacing at end of life, the net benefit of replacing now, and its cumulative and discounted values. Rows past the years compared are blank.
- A11 New Rated Figure
-
Unit W
About this output
New unit: The fan's power at the speed chosen (or the DOE test average), or your figure.
- A11 New Model Card
-
No unit declared
About this output
New unit: The fan as the calculator reads it: product type, year, watts at low and high speed and in standby, and the record it came from.
- A11 Old Annual Energy Cost
-
Unit $/yr
About this output
Old unit: Electricity cost in year 1.
- A11 NPV Replace Now
-
Unit $
About this output
Present value of keeping minus that of replacing now; positive means replacing now costs less.
- A11 New Annual Upkeep
-
Unit $/yr
About this output
New unit: The yearly upkeep you entered.
- A11 New Annual Energy Cost
-
Unit $/yr
About this output
New unit: Electricity cost in year 1.
- A11 Net Initial Cost
-
Unit $
About this output
Number of fans x price, plus sales tax, installation and disposal, less incentives and the old fans' sale value.
- A11 New Annual Total Cost
-
Unit $/yr
About this output
New unit: Electricity and upkeep in year 1.
- A11 New Annual KWh
-
Unit kWh/yr
About this output
New unit: Fans x (watts x hours + standby x the other hours of the day) x 365 / 1,000.
LogicCommons is in beta. If a result, label, or reference looks wrong, tell us here; we read every message.
What it is
This calculator weighs keeping your ceiling fans against replacing them. Pick the old fan from the ENERGY STAR lists or enter its watts, pick the new fan, and enter how many fans, how many hours a day they run, the speed and what you pay for electricity. It works out each fan's yearly energy use and cost, the yearly saving, the net cost of the new fans, the paybacks, and the cost over the years you choose of keeping the old fans, replacing them now, or replacing them when they wear out.
Fan figures come from federal sources only: the ENERGY STAR certified and historical lists published by the EPA, and the DOE test procedure. Default electricity prices come from the EIA. You set the price of the new fan; the opening example uses an illustrative one, not a quote or a current price.
Methodology
Purpose and model boundary
This calculator compares two ways forward for ceiling fans: keep the fans you have, or replace them with new ones. It takes each fan's power at the speed you use and its standby power, multiplies by the hours a day it runs and the number of fans, prices that at your electricity rate, and sets the yearly saving against what the new fans cost installed. Over the number of years you choose, it compares keeping them, replacing them now and, when you say how many years the old fans have left, replacing them when they wear out.
Every figure on this page is computed by the spreadsheet; the page adds nothing to it. The model covers running cost and purchase cost only. It does not judge performance, noise, size or reliability, and it does not price financing, warranties or your own time.
Inputs and units
- The old fan, described in one of three ways:
- a model from the ENERGY STAR Version 3 list (fans qualified from 2011 to 2018);
- a model from the current ENERGY STAR list;
- manual entry: its power in watts at the speed you use, and optionally its standby power.
- For a listed fan, pick the model from its list. Each entry reads "Brand | Model number", exactly as ENERGY STAR lists it; the product type (standard, hugger or high-speed small-diameter, with or without a light kit) is shown on the model card.
- The new fan: a model from the current ENERGY STAR list, or manual entry, and its price per fan, more than $0 and at most $5,000. The price is always yours to set; the examples use round illustrative prices, not quotes.
- Use: the number of fans (1 to 20), the hours a day they run (0 to 24; the default, 6.4, is the DOE test basis) and the speed: low, high, or the DOE test average.
- Electricity price, optional: the state, which sets the default price, or your own price in dollars per kWh.
- Purchase and upkeep: installation, removal and disposal of the old fans, sales tax on the price, verified rebates, the sale value of the old fans, and yearly upkeep. Each is optional and counts as zero when left blank.
- The comparison: the years to compare (1 to 30), the yearly change in electricity prices, the discount rate, and, optionally, the years the old fans have left and the expected life of the new ones.
Power is in watts, energy in kWh a year and money in dollars.
Governing relationships
Energy. Each fan uses its power at the chosen speed for the hours it runs and its standby power for the rest of the day: yearly kWh = fans × (watts × hours + standby watts × (24 − hours)) × 365 ÷ 1000. Light kits are not counted; lighting belongs to the LED conversion calculator.
The DOE test average. DOE's test procedure (Appendix U) runs a standard or hugger fan 3.4 hours a day at high speed and 3.0 hours at low speed, 6.4 hours in all, with 17.6 hours in standby. The test-average power is (3.4 × high-speed watts + 3.0 × low-speed watts) ÷ 6.4; for a single-speed fan it is its high-speed power.
Watts are the comparable figure. The current list rates efficiency as a weighted CFM per watt under DOE Appendix U, the Version 3 list as CFM per watt by speed under an older method; the two efficiencies are not comparable, but the power at low and high speed is. Version 3 fans report no standby power, which then counts as zero.
Yearly cost. For each ceiling fan, the yearly running cost is its yearly kWh times the electricity price; adding yearly upkeep gives its yearly cost, and the yearly saving is the old ceiling fan's yearly cost less the new one's.
Electricity price. Your own price, when you enter one, is used; otherwise the average residential price for the state you choose.
Purchase cost. The capital cost is the price × (1 + sales tax rate) + installation − rebates. The net initial cost adds removal and disposal and takes off the old unit's sale value.
Payback. Simple payback is the net initial cost ÷ the first year's saving, when the saving is positive; otherwise there is no payback. Discounted payback is the first year in which the cumulative discounted net benefit of replacing now reaches zero within the years compared.
The three paths over the years compared. Electricity prices change each year by the rate you enter; upkeep stays flat; costs fall at the end of each year and are discounted at your rate.
- Keep: the old unit's yearly cost every year.
- Replace now: the net initial cost today, then the new unit's yearly cost, less the value left in the new unit at the end.
- Replace at end of life (when you enter the years the old unit has left and they are fewer than the years compared): the old unit's yearly cost until it fails, then the capital cost and disposal in that year, then the new unit's yearly cost, less the value left in the new unit at the end.
The value left in the new unit at the end is its capital cost × the share of its expected life still remaining, on a straight line; with no expected life entered, no value is counted. The net present value of replacing now is the present cost of keeping less the present cost of replacing now: positive means replacing now costs less.
Calculation sequence
The spreadsheet first finds each unit's rated figure from the list, the federal standard for the year made or your entries, and checks the inputs. It then reduces each unit to a yearly energy figure that scales with your use, and from it computes the yearly kWh, the yearly costs and the saving. The purchase cost, the paybacks, the present values of the three paths and the year-by-year cash flow follow. The sensitivity table uses the same per-unit figures, so it cannot disagree with the main result. A block of consistency checks, including that the discounted cash flow reaches the same net present value as the closed-form formula, runs before the status is returned.
Outputs and interpretation
The headline is the yearly saving from replacing the old ceiling fan, with the simple payback and the net present value of replacing now. For each unit the results give its rated figure, its yearly kWh, and its yearly energy, upkeep and total cost, with the electricity price actually used and a note on where it came from. The decision results give the net initial cost, the discounted payback year, the total and present cost of keeping, of replacing now and of replacing at end of life, and a plain verdict on each.
The cash-flow table shows each year from 0 to the years compared: the cost of each path, the net benefit of replacing now, and its cumulative, discounted and cumulative discounted values. The sensitivity table shows the yearly saving at 1, 2, 4, 6, 8, 12, 16 and 24 hours a day, and at 0.5, 0.75, 1, 1.25 and 1.5 times the electricity price used.
A model card beside each pick shows the fan's product type, blade span, its power at low and high speed and in standby, its weighted efficiency and the year it was listed or became available.
The first chart, “Cumulative net benefit of replacing now, by year”, shows Undiscounted and Discounted by year. The second chart, “Cost over the years compared”, shows Total and Present value by option. The third chart, “Running cost in year 1”, shows Electricity and Upkeep by unit, stacked.
Validation and status logic
The workbook returns one status, chosen in this order: NOT VALID, then CHECK, then OK.
- NOT VALID names the first problem: a source that is not one of its options; a listed model that is not in its list; manual watts missing or not above 0 and at most 500; a manual standby outside 0 to 10 watts or an upkeep figure outside 0 to $5,000 a year; hours a day outside 0 to 24, a fan count that is not a whole number from 1 to 20, a speed that is not one of its options, or a speed whose power is not published for the listed fan (low speed, or the DOE test average, for a two-speed fan with no low-speed figure); no electricity price, or your own price outside $0.01 to $2.00 per kWh; a price for the new fan that is missing, not above $0 or above $5,000; another money or rate input outside its range; years to compare that are not a whole number from 1 to 30, or a growth or discount rate outside its range; years left that are not a whole number from 0 to 30, or an expected life that is not a whole number from 1 to 40.
NOT VALIDis a refusal, not a numeric answer: every figure reads zero and is withheld. - CHECK accompanies a computed result that needs the stated review: zero hours a day; a new unit that does not cost less to run than the old one at your use, so there is no payback; or an old unit with fewer years left than the years compared, so the end-of-life path is the realistic one.
- OK otherwise.
Assumptions and limitations
- 6.4 hours a day is the test basis, not your use. Your use enters through the hours and the speed you set.
- Light kits are left out. The fan's lighting power is listed separately and is not counted here.
- The historical list is a snapshot. It holds the Version 3 fans qualified from 2011 to 2018; older fans and fans never certified have no federal record and are entered manually. No federal limit on a fan's wattage exists, so there is no year-made route.
- Expected life. No federal lifetime for ceiling fans was found; enter the new fans' expected life if you want the value left in them at the end to count.
- The default electricity price is an average. It is the EIA's annual average residential price for the state, not your tariff. Enter your own price from your bill for a better answer.
- One price change rate applies to electricity in every year. The future purchase in the end-of-life path is priced at today's price.
- There is no loan, no depreciation other than the value left in the new unit at the end, and no resale other than the old unit's sale value when it is replaced now.
Data and vintage
The model lists and the federal standards are reviewed reference tables inside the workbook, refreshed from their federal publishers; their version is shown in the result details.
- Current models: the ENERGY STAR certified ceiling fans dataset (EPA), Version 4.0, 1,458 records downloaded 2026-10-28. Where a model is listed more than once, the most recent listing is used; one listing with an implausible 4,425 W is left out.
- Historical models: the ENERGY STAR Version 3 list, 400 fans qualified from 2011 to 2018, downloaded 2026-10-28.
- Default electricity prices: EIA 2025 annual average residential electricity prices by state (Form EIA-861).
Worked examples and prices
Prices are not part of the reference data: the price of the new unit is an input you set. The opening example and the five worked examples each use an illustrative price for the new unit, so that the example computes, and each says so: “Illustrative price for this example, not a quote or a current price. Prices vary: check current prices online or enter your own.”
Restrictions and non-computing states
The calculator enforces its numeric and choice limits before it accepts a result. A model that is not in its list, a manual fan with no wattage and a missing price for the new fan are refused by the workbook.
Errors and warnings
A request rejected by the page's input limits is not a computed result. A transport or service failure, a timeout or a cancelled run cannot establish a fresh workbook answer, and the last result stays on the page marked as out of date. Check your unit's EnergyGuide label or nameplate and your own bills before relying on a result for a purchase.
References
Sources and further reading
The calculator reads its model lists, its federal limits and its default electricity prices from reviewed reference tables inside the workbook, by record, with their version shown in the result details. Every table comes from a US federal source. The sources below publish the data and the rules the model applies. They do not endorse this calculator.
- ENERGY STAR Certified Ceiling Fans (EPA) lists currently certified ceiling fans with their power at low and high speed and in standby (retrieved 2026-10-28).
- ENERGY STAR, Ceiling fans: information for partners (EPA) links the last Version 3 list, posted before Version 4 took effect in 2018 (retrieved 2026-10-28).
- DOE test procedures, 10 CFR 430 Subpart B (eCFR), whose Appendix U runs a fan 3.4 hours a day at high speed and 3.0 hours at low speed (retrieved 2026-10-28).
- DOE energy conservation standards, 10 CFR 430.32 (eCFR) sets the federal design requirements for ceiling fans and, from 2020, their minimum efficiency (430.32(s)); it sets no limit on wattage (retrieved 2026-10-28).
- EIA, Detailed state data (Form EIA-861) gives the average residential electricity price by state, used here for 2025 (retrieved 2026-10-28).
This is an educational estimate of running and purchase costs for the units and prices you enter, not a product recommendation or a quote. The ENERGY STAR lists show each model's rated use under the DOE test procedure, not your unit's measured use.
Frequently asked questions
Which speed should I choose?
Does the fan's light count?
My old fan is not in the list. What should I do?
Why are old and new efficiency figures not compared?
Where does the new unit's price come from?
Is the electricity price my actual rate?