Calculator overview
Inputs and outputs
This summary comes from the calculator's published input and output contract.
Inputs
- A02 Old Manual Rating Basis (required) Conditional
-
Default Unknown Allowed EnergyGuide label from Sept 2014 or later, Earlier label, Unknown
About this input
Labels from September 2014 use the current DOE test; earlier labels used the older test. Unknown, the default, flags that the two figures may not be on the same test (DESIGN r1.5).
- A02 Old Manual KWh (required) Conditional
-
Unit kWh/yr Default 650 Range 0.1 to 3000
About this input
The yearly energy figure printed on the EnergyGuide label.
- A02 Old Sale Value
-
When omitted Blank
Unit $ Default Not set Range 0 to 5000
About this input
Money you receive for the old unit if you replace it now.
- A02 Old Remaining Life
-
When omitted Blank
Unit years Default Not set Range 0 to 30
About this input
Fills the replace-at-end-of-life comparison. Blank skips it.
- A02 Old Manual Icemaker (required) Conditional
-
Default No Allowed Yes, No
About this input
Yes adds the 84 kWh a year the current test counts for an icemaker when the label is an earlier one. No is the default (DESIGN r1.5).
- A02 Old Hist Model Cmp (required) Conditional
-
Default Absocold | ARD244A*10R/L Allowed Absocold | ARD244A*10R/L, Absocold | ARD252A*10R/L, Absocold | ARD298C*10R/L, Absocold | ARD298C*14R, Absocold | ARD369A*10R/L, Absocold | ARD492AS11R/L, Absocold | ARD565P*12R/L, Absocold | ARD565PW12R/L, Amana | AMA31**QE, Arctic King | AFRM024AES, and 601 more (the calculator lists them all)
About this input
Brand and model number as listed by ENERGY STAR (compact models). In a model number, * stands for any character.
- A02 Old Curr Model Full (required) Conditional
-
Default ABL | AREF18** Allowed ABL | AREF18**, ABL | AREF18B, ABL | AREF18S, ABL | AREF18W, Absocold | ARD1033FB21R/L, Absocold | ARD1033FS21R/L, Absocold | ARD1033FW21R/L, Amana | ART348FFF*** (no icemaker), Amana | ART348FFF*** (with icemaker), Amana | ARTX2314T*** (no icemaker), and 2,634 more (the calculator lists them all)
About this input
For an old unit that is still ENERGY STAR certified: brand and model number as listed today.
- A02 Old Maintenance
-
When omitted Blank
Unit $/yr Default Not set Range 0 to 5000
About this input
Repairs or service you expect each year if you keep the old unit.
- A02 Old Hist Model Full (required) Conditional
-
Default Samsung | RF34H9950** Allowed Absocold | ARD1031F*11R/L, Absocold | ARD1033FB10R/L, Absocold | ARD1033FS10R/L, Absocold | ARD1033FW10R/L, Aga | AFHR-36***, Aga | APRO36FD-***, Amana | A8RXDGFX*0*, Amana | A8RXEGFX*0*, Amana | A8TXEGFY*0*, Amana | ABB1921BR*, and 2,067 more (the calculator lists them all)
About this input
Brand and model number as listed by ENERGY STAR. In a model number, * stands for any character; the listing covers every model that fits.
- A02 Rate Growth
-
When omitted Blank
Default Not set Range -0.1 to 0.15
About this input
Blank means flat prices.
- A02 Old Vintage Total CuFt (required) Conditional
-
Unit cu ft Default 21 Range 1 to 40
About this input
Fresh-food plus freezer volume in cubic feet, from the label inside the door or the manual.
- A02 State (required)
-
Default US Allowed AK, AL, AR, AZ, CA, CO, CT, DC, DE, FL, GA, HI, IA, ID, IL, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, RI, SC, SD, TN, TX, UT, VA, VT, WA, WI, WV, WY, US
About this input
USPS state code, or US for the national average. The default is the state's average residential price, not your tariff.
- A02 Sales Tax Rate
-
When omitted Blank
Default Not set Range 0 to 0.15
About this input
Applied to the unit price only.
- A02 Old Vintage Freezer CuFt (required) Conditional
-
Unit cu ft Default 6 Range 0 to 40
About this input
The freezer part of the total volume (0 for a refrigerator with no freezer). It sets the adjusted volume the federal limit uses.
- A02 Old Type (required) Conditional
-
Default Full-size Allowed Full-size, Compact
About this input
Full-size or compact. It chooses which model list is shown, and it is compared with the new unit.
- A02 Old Source (required)
-
Default Model from historic ENERGY STAR list Allowed Model from historic ENERGY STAR list, Model from current ENERGY STAR list, Model not found: pick approximate age, Manual entry
About this input
Pick the model from the historic ENERGY STAR list (models qualified 2003-2014) or the current list; if it is not listed, pick its product class and the year it was made; or type the figure from its EnergyGuide label.
- A02 Old Vintage Class (required) Conditional
-
Default Top freezer, automatic defrost Allowed Top freezer, automatic defrost, Bottom freezer, automatic defrost, Side-by-side, automatic defrost, Refrigerator only, automatic defrost, Manual defrost (any), Compact, manual defrost, Compact, automatic defrost
About this input
When the model is not listed: the kind of refrigerator, which sets the federal limit that applied to it.
- A02 Old Vintage (required) Conditional
-
Default Made in 1998 Allowed Made in 1990, Made in 1991, Made in 1992, Made in 1993, Made in 1994, Made in 1995, Made in 1996, Made in 1997, Made in 1998, Made in 1999, Made in 2000, Made in 2001, Made in 2002, Made in 2003, Made in 2004, Made in 2005, Made in 2006, Made in 2007, Made in 2008, Made in 2009, Made in 2010, Made in 2011, Made in 2012, Made in 2013, Made in 2014, Made in 2015, Made in 2016, Made in 2017, Made in 2018, Made in 2019, Made in 2020, Made in 2021, Made in 2022, Made in 2023, Made in 2024, Made in 2025
About this input
The federal maximum allowed for units made that year is used (the standard in force on 1 January of that year). Your unit may use less, so savings may be overstated.
- A02 Old Curr Model Cmp (required) Conditional
-
Default Absocold | ARD104AB21R/L Allowed Absocold | ARD104AB21R/L, Absocold | ARD204AB21R/L, Absocold | ARD204ABS21R/L, Absocold | ARD244A*21R/L, Absocold | ARD369A*14R/L, Absocold | ARD484F*10R/L, Absocold | ARD484F*21R/L, Amana | AMA31**E, Amana | AMA31S5E, Amana | AMA43BKE, and 1,669 more (the calculator lists them all)
About this input
For a compact old unit that is still ENERGY STAR certified: brand and model number as listed today.
- A02 Installation
-
When omitted Blank
Unit $ Default Not set Range 0 to 5000
About this input
Your quote. Not included unless entered.
- A02 Incentives
-
When omitted Blank
Unit $ Default Not set Range 0 to 5000
About this input
Only incentives you have confirmed you qualify for.
- A02 New Expected Life
-
When omitted Blank
Unit years Default Not set Range 1 to 40
About this input
Used for the value left in the new unit at the end of the period (straight line). Blank uses the DOE mean lifetime: 17.43 years for a full-size unit, 5.62 for a compact one.
- A02 Location (required)
-
Default Kitchen or other heated and cooled room Allowed Kitchen or other heated and cooled room, Garage or unheated space, Unheated basement
About this input
No federal source gives a factor for a garage or a cold basement, so the location does not change the figure; a note explains, and you may enter an adjustment.
- A02 Horizon Years (required)
-
Unit years Default 10 Range 1 to 30
About this input
The comparison period, 1 to 30 whole years.
- A02 Disposal
-
When omitted Blank
Unit $ Default Not set Range 0 to 1000
About this input
Haul-away or recycling charge, if any.
- A02 Discount Rate
-
When omitted Blank
Default Not set Range 0 to 0.2
About this input
Blank means no discounting.
- A02 Energy Adjustment
-
When omitted Blank
Default Not set Range -0.5 to 1
About this input
If you know your unit uses more or less than its label, for example in a hot garage: -50% to +100%.
- A02 Electricity Rate Override
-
When omitted Blank
Unit $/kWh Default Not set Range 0.01 to 2
About this input
From your bill. Overrides the state average.
- A02 New Price (required)
-
Unit $ Default 1200 Range 1 to 20000
About this input
The price you expect to pay for the unit itself. The calculator never looks up a price. Illustrative price for this example, not a quote or a current price. Prices vary: check current prices online or enter your own.
- A02 New Model Full (required) Conditional
-
Default Avanti | FF18H** Allowed ABL | AREF18**, ABL | AREF18B, ABL | AREF18S, ABL | AREF18W, Absocold | ARD1033FB21R/L, Absocold | ARD1033FS21R/L, Absocold | ARD1033FW21R/L, Amana | ART348FFF*** (no icemaker), Amana | ART348FFF*** (with icemaker), Amana | ARTX2314T*** (no icemaker), and 2,634 more (the calculator lists them all)
About this input
Brand and model number as listed by ENERGY STAR today. In a model number, * stands for any character.
- A02 New Type (required)
-
Default Full-size Allowed Full-size, Compact
About this input
Full-size or compact. It chooses which model list is shown.
- A02 New Source (required)
-
Default Model from current ENERGY STAR list Allowed Model from current ENERGY STAR list, Manual entry
About this input
Pick a currently certified ENERGY STAR model, or type the figure from its EnergyGuide label.
- A02 New Model Cmp (required) Conditional
-
Default Absocold | ARD104AB21R/L Allowed Absocold | ARD104AB21R/L, Absocold | ARD204AB21R/L, Absocold | ARD204ABS21R/L, Absocold | ARD244A*21R/L, Absocold | ARD369A*14R/L, Absocold | ARD484F*10R/L, Absocold | ARD484F*21R/L, Amana | AMA31**E, Amana | AMA31S5E, Amana | AMA43BKE, and 1,669 more (the calculator lists them all)
About this input
Brand and model number as listed by ENERGY STAR today (compact models).
- A02 New Manual Icemaker (required) Conditional
-
Default No Allowed Yes, No
About this input
Yes adds the 84 kWh a year icemaker allowance when the label is an earlier one. No is the default (DESIGN r1.5).
- A02 New Maintenance
-
When omitted Blank
Unit $/yr Default Not set Range 0 to 5000
About this input
Service you expect each year for the new unit.
- A02 New Manual Rating Basis (required) Conditional
-
Default Unknown Allowed EnergyGuide label from Sept 2014 or later, Earlier label, Unknown
About this input
Labels from September 2014 use the current DOE test. Unknown, the default, flags that the two figures may not be on the same test (DESIGN r1.5).
- A02 New Manual KWh (required) Conditional
-
Unit kWh/yr Default 400 Range 0.1 to 3000
About this input
The yearly energy figure on the EnergyGuide label of the new unit.
Outputs
- A02 PV Keep
-
Unit $
About this output
Present value of keeping the old unit at the discount rate.
- A02 Old Rated Figure
-
Unit kWh/yr
About this output
Old unit: The yearly energy figure used for the unit: its rating, the federal maximum for the year it was made, or your label figure, plus the 84 kWh icemaker adder where it applies.
- A02 PV Replace Now
-
Unit $
About this output
Present value of replacing now at the discount rate.
- A02 PV Replace End Of Life
-
Unit $
About this output
Present value of replacing when the old unit fails. Blank when not evaluated.
- A02 Old Model Card
-
No unit declared
About this output
Old unit: The unit as the calculator reads it: type, configuration, year, rated energy, icemaker and the record it came from.
- A02 Old Annual KWh
-
Unit kWh/yr
About this output
Old unit: The rated figure times the energy-use factor (location factor times your adjustment).
- A02 Old Annual Energy Cost
-
Unit $/yr
About this output
Old unit: Electricity cost in year 1.
- A02 Old Annual Upkeep
-
Unit $/yr
About this output
Old unit: The yearly upkeep you entered for the unit.
- A02 Old Annual Total Cost
-
Unit $/yr
About this output
Old unit: Electricity and upkeep in year 1.
- A02 Replace Now Verdict
-
No unit declared
About this output
The comparison of replacing now with keeping, in words.
- A02 Total Replace End Of Life
-
Unit $
About this output
Keep the old unit until it fails, then buy the new one at today's price. Blank when no remaining life below the period is given.
- A02 Total Keep
-
Unit $
About this output
Running cost of keeping the old unit over the years compared, without discounting.
- Model Status
-
No unit declared
About this output
OK, CHECK with a reason to read, or NOT VALID with what to fix.
- A02 Total Replace Now
-
Unit $
About this output
Net initial cost plus the new unit's running cost over the years compared, less the value left at the end, without discounting.
- A02 Status Code
-
No unit declared
About this output
The deciding reason of the status line as a short code, OK when nothing applies.
- A02 Sensitivity Savings
-
No unit declared
About this output
Money saved in year 1 at 0.8 to 1.5 times the label energy use (rows) and 50% to 150% of the electricity price used (columns).
- A02 Self Check
-
No unit declared
About this output
Whether the model's internal consistency checks hold.
- A02 Simple Payback Years
-
Unit years
About this output
Net initial cost divided by the money saved in year 1. Blank when nothing is saved or the price is missing.
- A02 Simple Payback Text
-
No unit declared
About this output
The simple payback in words: the years, no payback, or a missing price.
- A02 NPV Replace Now
-
Unit $
About this output
Present value of keeping minus that of replacing now; positive means replacing now costs less.
- A02 Electricity Rate Note
-
No unit declared
About this output
Where the electricity price comes from: the EIA state average and its year, or your own price.
- A02 Discounted Payback Year
-
Unit year
About this output
The first year in which the cumulative discounted net benefit of replacing now reaches zero. Blank when it does not within the years compared.
- A02 End Of Life Verdict
-
No unit declared
About this output
The comparison of replacing now with waiting until the old unit fails, in words.
- A02 Electricity Rate Used
-
Unit $/kWh
About this output
The electricity price in the sums: your own, or the state average.
- A02 Discounted Payback Text
-
No unit declared
About this output
The discounted payback in words.
- A02 Annual Savings USD
-
Unit $/yr
About this output
Old minus new running cost in year 1; negative means the new unit costs more to run.
- A02 Annual Energy Savings KWh
-
Unit kWh/yr
About this output
Old minus new electricity a year; negative means the new unit uses more.
- A02 Data Vintage Note
-
No unit declared
About this output
The sources and their dates.
- A02 Cash Flow
-
No unit declared
About this output
Year-by-year costs of keeping, replacing now and replacing at end of life, the net benefit of replacing now, and its cumulative and discounted values. Rows past the years compared are blank.
- A02 Energy Factor Used
-
No unit declared
About this output
The location factor (1.00 everywhere: no federal factor) times one plus your adjustment.
- A02 New Annual Upkeep
-
Unit $/yr
About this output
New unit: The yearly upkeep you entered for the unit.
- A02 New Annual Total Cost
-
Unit $/yr
About this output
New unit: Electricity and upkeep in year 1.
- A02 New Rated Figure
-
Unit kWh/yr
About this output
New unit: The yearly energy figure used for the unit: its rating, the federal maximum for the year it was made, or your label figure, plus the 84 kWh icemaker adder where it applies.
- A02 New Model Card
-
No unit declared
About this output
New unit: The unit as the calculator reads it: type, configuration, year, rated energy, icemaker and the record it came from.
- A02 New Annual KWh
-
Unit kWh/yr
About this output
New unit: The rated figure times the energy-use factor (location factor times your adjustment).
- A02 Location Note
-
No unit declared
About this output
What the location means for the result: a note, not a status (no federal location factor).
- A02 Expected Life Note
-
No unit declared
About this output
Which expected life is used for the value left in the new unit: yours, or the DOE mean lifetime for its type.
- A02 New Annual Energy Cost
-
Unit $/yr
About this output
New unit: Electricity cost in year 1.
- A02 Net Initial Cost
-
Unit $
About this output
Price, sales tax, installation and disposal, less incentives and the old unit's sale value.
LogicCommons is in beta. If a result, label, or reference looks wrong, tell us here; we read every message.
What it is
This calculator weighs keeping your refrigerator against replacing it. Describe the old unit by picking its model from the ENERGY STAR lists, by the year it was made and its size, or from the energy figure on its EnergyGuide label. Then pick the new model and say where the unit stands and what you pay for electricity. It works out each unit's yearly energy use and cost, the yearly saving, the net cost of the new unit, the simple and discounted payback, and the cost over the years you choose of keeping the old unit, replacing it now, or replacing it when it wears out.
Model figures come from federal sources only: the ENERGY STAR certified and historical lists published by the EPA, and the DOE efficiency standards. Default electricity prices come from the EIA. You set the price of the new unit; the opening example uses an illustrative one, not a quote or a current price.
Methodology
Purpose and model boundary
This calculator compares two ways forward for a household refrigerator: keep the unit you have, or replace it with a new one. It takes each unit's rated yearly energy use, adjusts it if you say your unit uses more or less than its label, prices it at your electricity rate, and sets the yearly saving against what the new unit costs installed. Over the number of years you choose, it compares keeping the old unit, replacing it now and, when you say how many years the old unit has left, replacing it when it wears out.
Every figure on this page is computed by the spreadsheet; the page adds nothing to it. The model covers running cost and purchase cost only. It does not judge performance, noise, size or reliability, and it does not price financing, warranties or your own time.
Inputs and units
- The old refrigerator, described in one of four ways:
- a model from the ENERGY STAR historical lists (models qualified from 2003 to 2014);
- a model from the current ENERGY STAR list, for a unit that is still certified;
- the year it was made and its product class, when the model is not listed, with its total and freezer volumes: the calculator then uses the federal maximum allowed for that class, size and year;
- manual entry: the yearly energy figure from its EnergyGuide label, the label's rating basis (it starts at Unknown) and whether the unit has an automatic icemaker (it starts at No).
- Type: Full-size or Compact, for each unit. For a listed model, choose the type first, then pick the model from that type's list. Each entry reads "Brand | Model number", exactly as ENERGY STAR lists it.
- The new refrigerator: a model from the current ENERGY STAR list, or manual entry as for the old unit, and its price, more than $0 and at most $20,000. The price is always yours to set; the examples use round illustrative prices, not quotes.
- Where it stands: a kitchen or other heated and cooled room, a garage or unheated space, or an unheated basement; and, optionally, how much more or less energy your unit uses than its label, from −50% to +100%.
- Electricity price, optional: the state, which sets the default price, or your own price in dollars per kWh.
- Purchase and upkeep: installation, removal and disposal of the old unit, sales tax on the price, verified rebates, the sale or scrap value of the old unit, and yearly upkeep for each unit. Each is optional and counts as zero when left blank.
- The comparison: the years to compare (1 to 30), the yearly change in electricity prices, the discount rate, and, optionally, the years the old unit has left and the expected life of the new unit.
Energy is in kWh a year, volume in cubic feet and money in dollars.
Governing relationships
The rated figure. An ENERGY STAR or EnergyGuide figure for a refrigerator is its yearly energy use under the DOE test procedure, and the calculator uses it directly: it does not depend on how often you open the door. The figure is multiplied by your adjustment, if you enter one.
Where it stands. No federal source gives a factor for a refrigerator in a garage or a cold basement, so the location does not change the figure. A unit outside a heated and cooled room shows a note: the label is measured at a fixed test temperature, a unit in a hot garage uses more and one in a cold space may use less, and you may enter an adjustment if you know it.
Two test procedures. DOE changed the test procedure with the 2014 standards. Current listings are rated under the 2014 procedure; many older listings carry a figure rated under the 2001 procedure instead. When the old and new figures come from different procedures, the comparison is not strictly like for like, and the status says so.
Icemakers. A unit with an automatic icemaker whose figure was rated under the procedure before September 2014 gets 84 kWh a year added, the icemaker energy the 2014 procedure counts. Where an older list does not say whether a model has an icemaker, nothing is added, and the model card says so. For 20 older listings, the icemaker is inferred from the 84 kWh difference in their federal standard, and the model card says that too.
A unit described by the year it was made.
- No DOE study gives the typical energy use of refrigerators by year made, so the calculator uses the federal maximum: the most energy a unit of that product class and adjusted volume was allowed to use, from the standards of 1990, 1993, 2001 and 2014 (10 CFR 430.32(a)). It is a ceiling, not a measurement: your unit may use less, and the saving may be overstated.
- The adjusted volume is the fresh-food volume plus a factor × the freezer volume: 1.63 for units made before 2014 and 1.76 from 2014. You enter the total and freezer volumes on this route.
- A year in which the standard changed part-way uses the standard in force on 1 January of that year. A unit made before 1990, when the first federal standard took effect, is entered manually.
Yearly cost. For each refrigerator, the yearly running cost is its yearly kWh times the electricity price; adding yearly upkeep gives its yearly cost, and the yearly saving is the old refrigerator's yearly cost less the new one's.
Electricity price. Your own price, when you enter one, is used; otherwise the average residential price for the state you choose.
Purchase cost. The capital cost is the price × (1 + sales tax rate) + installation − rebates. The net initial cost adds removal and disposal and takes off the old unit's sale value.
Payback. Simple payback is the net initial cost ÷ the first year's saving, when the saving is positive; otherwise there is no payback. Discounted payback is the first year in which the cumulative discounted net benefit of replacing now reaches zero within the years compared.
The three paths over the years compared. Electricity prices change each year by the rate you enter; upkeep stays flat; costs fall at the end of each year and are discounted at your rate.
- Keep: the old unit's yearly cost every year.
- Replace now: the net initial cost today, then the new unit's yearly cost, less the value left in the new unit at the end.
- Replace at end of life (when you enter the years the old unit has left and they are fewer than the years compared): the old unit's yearly cost until it fails, then the capital cost and disposal in that year, then the new unit's yearly cost, less the value left in the new unit at the end.
The value left in the new unit at the end is its capital cost × the share of its expected life still remaining, on a straight line; with no expected life entered, the DOE mean lifetime for the unit's type is used. The net present value of replacing now is the present cost of keeping less the present cost of replacing now: positive means replacing now costs less.
Calculation sequence
The spreadsheet first finds each unit's rated figure from the list, the federal standard for the year made or your entries, and checks the inputs. It then reduces each unit to a yearly energy figure that scales with your use, and from it computes the yearly kWh, the yearly costs and the saving. The purchase cost, the paybacks, the present values of the three paths and the year-by-year cash flow follow. The sensitivity table uses the same per-unit figures, so it cannot disagree with the main result. A block of consistency checks, including that the discounted cash flow reaches the same net present value as the closed-form formula, runs before the status is returned.
Outputs and interpretation
The headline is the yearly saving from replacing the old refrigerator, with the simple payback and the net present value of replacing now. For each unit the results give its rated figure, its yearly kWh, and its yearly energy, upkeep and total cost, with the electricity price actually used and a note on where it came from. The decision results give the net initial cost, the discounted payback year, the total and present cost of keeping, of replacing now and of replacing at end of life, and a plain verdict on each.
The cash-flow table shows each year from 0 to the years compared: the cost of each path, the net benefit of replacing now, and its cumulative, discounted and cumulative discounted values. The sensitivity table shows the yearly saving at 0.8, 0.9, 1, 1.1, 1.2, 1.3 and 1.5 times the label's energy use, and at 0.5, 0.75, 1, 1.25 and 1.5 times the electricity price used.
A model card beside each pick shows the model's configuration, volumes, rated kWh a year, rating basis and the year it was listed or became available.
The first chart, “Cumulative net benefit of replacing now, by year”, shows Undiscounted and Discounted by year. The second chart, “Cost over the years compared”, shows Total and Present value by option. The third chart, “Running cost in year 1”, shows Electricity and Upkeep by unit, stacked.
Validation and status logic
The workbook returns one status, chosen in this order: NOT VALID, then CHECK, then OK.
- NOT VALID names the first problem: a source that is not one of its options; a listed model that is not in its list or whose type differs from the type chosen, or, for a unit described by the year made, no class or year, or no federal standard for them (before 1990); a total volume missing or outside 1 to 40 cubic feet, or a freezer volume missing, negative or larger than the total; a manual label figure missing or not above 0 and at most 3,000 kWh a year; a manual rating basis that is not one of its options; an upkeep figure outside 0 to $5,000 a year; a location that is not one of its options, or an energy-use adjustment outside −50% to +100%; no electricity price, or your own price outside $0.01 to $2.00 per kWh; a price for the new unit that is missing, not above $0 or above $20,000; another money or rate input outside its range; years to compare that are not a whole number from 1 to 30, or a growth or discount rate outside its range; years left that are not a whole number from 0 to 30, or an expected life that is not a whole number from 1 to 40.
NOT VALIDis a refusal, not a numeric answer: every figure reads zero and is withheld. - CHECK accompanies a computed result that needs the stated review: an old unit described by the year it was made, so its figure is the federal limit for that year: your unit may use less and the saving may be overstated; a manual entry whose rating basis is Unknown; old and new figures rated under different DOE test procedures (2001 and 2014), so they are not strictly comparable; old and new units of different types (full-size and compact); a new unit that does not cost less to run than the old one at your use, so there is no payback; or an old unit with fewer years left than the years compared, so the end-of-life path is the realistic one.
- OK otherwise.
Assumptions and limitations
- The historical lists are snapshots. They hold the ENERGY STAR models qualified when the specification changed in September 2014 (lists for Version 4); models certified after 2014 and later withdrawn, and models from before 2003 unless still listed in 2014, are missing. Only ENERGY STAR models appear, so the baseline leans efficient, and the saving may be understated if you pick a listed model to stand in for a different unit.
- The federal maximum is a ceiling, not a measurement. A unit described by the year it was made may use less, so the saving may be overstated.
- The label is measured at test conditions, not in your home. Your adjustment, if you enter one, is the only way your conditions enter the result.
- Beverage coolers are not included. Wine and beverage coolers are a separate federal product and are left out of the lists.
- Expected life. With no expected life entered, the calculator uses DOE's mean lifetime, 17.43 years for a standard-size refrigerator (5.62 for a compact one), an analysis estimate rather than a warranty, and counts the value left in the new unit at the end on that life.
- The default electricity price is an average. It is the EIA's annual average residential price for the state, not your tariff. Enter your own price from your bill for a better answer.
- One price change rate applies to electricity in every year. The future purchase in the end-of-life path is priced at today's price.
- There is no loan, no depreciation other than the value left in the new unit at the end, and no resale other than the old unit's sale value when it is replaced now.
Data and vintage
The model lists and the federal standards are reviewed reference tables inside the workbook, refreshed from their federal publishers; their version is shown in the result details.
- Current models: the ENERGY STAR certified residential refrigerators dataset (EPA), 4,892 records downloaded 2026-10-28, without the beverage coolers. Where a model is listed more than once, the most recent listing is used.
- Historical models: the ENERGY STAR Version 4 and 4.1 lists posted in 2014, models qualified from 2003 to 2014, downloaded 2026-10-28. Their yearly figure is rated under the 2001 procedure for 2,697 records and under the 2014 procedure for 596.
- Year made: the federal maximum energy use by product class and adjusted volume from 10 CFR 430.32(a), for units made from 1990, with the standards of 1990, 1993, 2001 and 2014.
- Default electricity prices: EIA 2025 annual average residential electricity prices by state (Form EIA-861).
Worked examples and prices
Prices are not part of the reference data: the price of the new unit is an input you set. The opening example and the five worked examples each use an illustrative price for the new unit, so that the example computes, and each says so: “Illustrative price for this example, not a quote or a current price. Prices vary: check current prices online or enter your own.”
Restrictions and non-computing states
The calculator enforces its numeric and choice limits before it accepts a result. A model that is not in its list or does not match the type chosen, a unit described by a year with no federal standard, a manual unit with no label figure and a missing price for the new unit are refused by the workbook.
Errors and warnings
A request rejected by the page's input limits is not a computed result. A transport or service failure, a timeout or a cancelled run cannot establish a fresh workbook answer, and the last result stays on the page marked as out of date. Check your unit's EnergyGuide label or nameplate and your own bills before relying on a result for a purchase.
References
Sources and further reading
The calculator reads its model lists, its federal limits and its default electricity prices from reviewed reference tables inside the workbook, by record, with their version shown in the result details. Every table comes from a US federal source. The sources below publish the data and the rules the model applies. They do not endorse this calculator.
- ENERGY STAR Certified Residential Refrigerators (EPA) lists currently certified refrigerators with their yearly energy use under the 2014 DOE test procedure (retrieved 2026-10-28).
- ENERGY STAR, Refrigerators: information for partners (EPA) links the historical lists of refrigerators and freezers qualified under Version 4, posted in 2014 (retrieved 2026-10-28).
- DOE energy conservation standards, 10 CFR 430.32 (eCFR) sets the federal maximum yearly energy use by product class and adjusted volume; the 1997 and 2012 editions on govinfo hold the earlier standards (retrieved 2026-10-28).
- DOE, Residential refrigerators, refrigerator-freezers and freezers final rule technical support document (2011) estimates the mean life of a refrigerator at 17.43 years (retrieved 2026-10-28).
- EIA, Detailed state data (Form EIA-861) gives the average residential electricity price by state, used here for 2025 (retrieved 2026-10-28).
This is an educational estimate of running and purchase costs for the units and prices you enter, not a product recommendation or a quote. The ENERGY STAR lists show each model's rated use under the DOE test procedure, not your unit's measured use.
Frequently asked questions
My model number is not in the list. What should I do?
Why does the year-made route warn that the saving may be overstated?
My refrigerator is in the garage. Does that change the result?
Why does the status say the figures are not strictly comparable?
Where does the new unit's price come from?
Is the electricity price my actual rate?
Found a problem, or have an idea?
Tell us if a result looks wrong, a label is unclear, or something is missing. We read every message.