Home And Transportation Savings

Dehumidifier Replacement Calculator

Compares keeping your dehumidifier with replacing it: the water the old unit removes at your hours, each unit's yearly electricity from its ENERGY STAR or DOE efficiency, the running cost, simple and discounted payback, and the total and present-value cost of keeping, replacing now or replacing when the old unit fails. Estimates for planning, not financial advice.

Last updated

How to Use the Dehumidifier Replacement Calculator: Keep Your Old Dehumidifier or Replace It?

Plays from YouTube. Close the video to keep working on your drawing.

Calculator overview

Inputs and outputs

This summary comes from the calculator's published input and output contract.

Inputs

A10 Old Manual Rating Basis (required) Conditional
About this input

IEF for labels from June 2019, EF for earlier ones. Unknown, the default, flags that the two figures may not be on the same test (DESIGN r1.5).

Default Unknown Allowed IEF (label from June 2019 or later), EF (earlier label), Unknown
A10 Old Manual Efficiency (required) Conditional
About this input

Energy factor (EF, older labels) or integrated energy factor (IEF, labels from June 2019), in liters per kWh.

Unit L/kWh Default 1.4 Range 0.01 to 10
A10 Old Sale Value
When omitted Blank
About this input

Money you receive for the old unit if you replace it now.

Unit $ Default Not set Range 0 to 5000
A10 Old Remaining Life
When omitted Blank
About this input

Fills the replace-at-end-of-life comparison. Blank skips it.

Unit years Default Not set Range 0 to 30
A10 Old Manual Capacity Pints (required) Conditional
About this input

Water removal capacity in pints a day, from the label or manual.

Unit pints/day Default 50 Range 0.1 to 300
A10 Old Hist Model Port (required) Conditional
About this input

Brand and model number as listed by ENERGY STAR. In a model number, * stands for any character. Older lists do not give a type; those units are treated as portable.

Default ALORAIR | Galaxy 85P Allowed ABESTORM | Guardian SN35P, ABESTORM | Guardian SN55S, ABESTORM | Guardian SN90, Aeocky | RHEA-RCS25(Y)-N4-3, AEONAIR | RDH30EB, AEONAIR | RDH30EB-1, AEONAIR | RDH45EB, AEONAIR | RDH45EB-1, AEONAIR | RDH60EAW, AEONAIR | RDH70EA, and 1,328 more (the calculator lists them all)
A10 Old Curr Model Whole (required) Conditional
About this input

For a whole-home old unit that is still ENERGY STAR certified: brand and model number as listed today.

Default Aprilaire | E080 Allowed Aprilaire | E080, Aprilaire | E100, Aprilaire | E130, CARRIER CORPORATION | DEHXXCDA1080*, CARRIER CORPORATION | DEHXXCDA1100*, Healthy Climate | HCWHD#-080, Healthy Climate | HCWHD#-100, Healthy Climate | HCWHD#-130, Honeywell Home | DHM065R4000/U, Honeywell Home | DHM090R4000, Honeywell Home | DHM120R4000/U, MOISWELL | Admiral W160, MOISWELL | Admiral WP160, MOISWELL | Director W160, MOISWELL | Director WP160, MOISWELL | Marshal WD160, MOISWELL | Marshal WP160, Santa Fe | 4046180, Santa Fe | 4047100, Santa Fe | 4047200, Santa Fe | 4047300
A10 Old Maintenance
When omitted Blank
About this input

Repairs or service you expect each year if you keep the old unit.

Unit $/yr Default Not set Range 0 to 5000
A10 Old Hist Model Whole (required) Conditional
About this input

Brand and model number as listed by ENERGY STAR (whole-home models).

Default Field Controls LLC | DH-120 Allowed Field Controls LLC | DH-120, Field Controls LLC | DH-85, Honeywell Home | DR120A3000, Honeywell Home | DR90A3000
A10 Rate Growth
When omitted Blank
About this input

Blank means flat prices.

Default Not set Range -0.1 to 0.15
A10 Old Vintage Class (required) Conditional
About this input

When the model is not listed: portable or whole-home, which sets the federal limit that applied to it.

Default Portable Allowed Portable, Whole-home
A10 State (required)
About this input

USPS state code, or US for the national average. The default is the state's average residential price, not your tariff.

Default US Allowed AK, AL, AR, AZ, CA, CO, CT, DC, DE, FL, GA, HI, IA, ID, IL, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, RI, SC, SD, TN, TX, UT, VA, VT, WA, WI, WV, WY, US
A10 Sales Tax Rate
When omitted Blank
About this input

Applied to the unit price only.

Default Not set Range 0 to 0.15
A10 Old Vintage Case CuFt (required) Conditional
About this input

For a whole-home unit made from 2020: its case volume, which sets the federal band.

Unit cu ft Default 6 Range 0 to 50
A10 Old Type (required) Conditional
About this input

Portable or whole-home. It chooses which model list is shown, and it is compared with the new unit.

Default Portable Allowed Portable, Whole-home
A10 Old Source (required)
About this input

Pick the model from the historic ENERGY STAR lists (Versions 3, 4 and 5) or the current list; if it is not listed, pick its class, the year it was made and its capacity; or type its capacity and efficiency.

Default Model from historic ENERGY STAR list Allowed Model from historic ENERGY STAR list, Model from current ENERGY STAR list, Model not found: pick approximate age, Manual entry
A10 Old Vintage Capacity Pints (required) Conditional
About this input

Water removal capacity in pints a day, from the label or manual. It sets the federal band and the water the unit removes.

Unit pints/day Default 50 Range 0.1 to 300
A10 Old Vintage (required) Conditional
About this input

The lowest efficiency the federal standard allowed for units made that year is used (the standard in force on 1 January). Your unit may use less energy, so savings may be overstated.

Default Made in 2010 Allowed Made in 2008, Made in 2009, Made in 2010, Made in 2011, Made in 2012, Made in 2013, Made in 2014, Made in 2015, Made in 2016, Made in 2017, Made in 2018, Made in 2019, Made in 2020, Made in 2021, Made in 2022, Made in 2023, Made in 2024, Made in 2025
A10 Installation
When omitted Blank
About this input

Your quote. Not included unless entered.

Unit $ Default Not set Range 0 to 5000
A10 Incentives
When omitted Blank
About this input

Only incentives you have confirmed you qualify for.

Unit $ Default Not set Range 0 to 5000
A10 New Maintenance
When omitted Blank
About this input

Service you expect each year for the new unit.

Unit $/yr Default Not set Range 0 to 5000
A10 New Expected Life
When omitted Blank
About this input

Used for the value left in the new unit at the end of the period (straight line). Blank counts no value left: no federal lifetime for dehumidifiers was found.

Unit years Default Not set Range 1 to 40
A10 Hours Per Year (required)
About this input

Hours a year it runs removing water. The default, 1,095, is the DOE test procedure's figure (10 CFR 430 Subpart B Appendix X1); your season may be shorter or longer.

Unit hours/yr Default 1095 Range 0 to 8760
A10 Disposal
When omitted Blank
About this input

Recycling charge, if any.

Unit $ Default Not set Range 0 to 1000
A10 Discount Rate
When omitted Blank
About this input

Blank means no discounting.

Default Not set Range 0 to 0.2
A10 Horizon Years (required)
About this input

The comparison period, 1 to 30 whole years.

Unit years Default 10 Range 1 to 30
A10 Electricity Rate Override
When omitted Blank
About this input

From your bill. Overrides the state average.

Unit $/kWh Default Not set Range 0.01 to 2
A10 New Source (required)
About this input

Pick a currently certified ENERGY STAR model, or type its capacity and efficiency.

Default Model from current ENERGY STAR list Allowed Model from current ENERGY STAR list, Manual entry
A10 New Price (required)
About this input

The price you expect to pay for the unit itself. The calculator never looks up a price. Illustrative price for this example, not a quote or a current price. Prices vary: check current prices online or enter your own.

Unit $ Default 300 Range 1 to 10000
A10 Old Curr Model Port (required) Conditional
About this input

For an old unit that is still ENERGY STAR certified: brand and model number as listed today.

Default ABESTORM | Guardian SN55S Allowed ABESTORM | Guardian SN55S, Aeocky | CS25YA8N7F3(HUMMIGO-25US), Aeocky | LEO PRO-RCS50(Y)-N4-3(B)-25, Aeocky | LEO-RCS25(Y)-N4-3, Aeocky | LEO-RCS25(Y)-N4-3(B)-25, Aeocky | LEO-RCS32(Y)-N4-3(B), Aeocky | RHEA PRO-RCS50(Y)-N4-3-25, Aeocky | RHEA-RCS25(Y)-N4-3-25, Aeocky | RHEA-RCS32(Y)-N4-3, AERIC | AERD501P, and 506 more (the calculator lists them all)
A10 New Type (required)
About this input

Portable or whole-home. It chooses which model list is shown.

Default Portable Allowed Portable, Whole-home
A10 New Model Whole (required) Conditional
About this input

Brand and model number as listed by ENERGY STAR today (whole-home models).

Default Aprilaire | E080 Allowed Aprilaire | E080, Aprilaire | E100, Aprilaire | E130, CARRIER CORPORATION | DEHXXCDA1080*, CARRIER CORPORATION | DEHXXCDA1100*, Healthy Climate | HCWHD#-080, Healthy Climate | HCWHD#-100, Healthy Climate | HCWHD#-130, Honeywell Home | DHM065R4000/U, Honeywell Home | DHM090R4000, Honeywell Home | DHM120R4000/U, MOISWELL | Admiral W160, MOISWELL | Admiral WP160, MOISWELL | Director W160, MOISWELL | Director WP160, MOISWELL | Marshal WD160, MOISWELL | Marshal WP160, Santa Fe | 4046180, Santa Fe | 4047100, Santa Fe | 4047200, Santa Fe | 4047300
A10 New Manual Efficiency (required) Conditional
About this input

Integrated energy factor (IEF) of the new unit, in liters per kWh.

Unit L/kWh Default 2 Range 0.01 to 10
A10 New Manual Capacity Pints (required) Conditional
About this input

Water removal capacity of the new unit in pints a day.

Unit pints/day Default 50 Range 0.1 to 300
A10 New Model Port (required) Conditional
About this input

Brand and model number as listed by ENERGY STAR today.

Default Vellgoo | TAURUS PRO-RCS50(Y)-N4-3-25 Allowed ABESTORM | Guardian SN55S, Aeocky | CS25YA8N7F3(HUMMIGO-25US), Aeocky | LEO PRO-RCS50(Y)-N4-3(B)-25, Aeocky | LEO-RCS25(Y)-N4-3, Aeocky | LEO-RCS25(Y)-N4-3(B)-25, Aeocky | LEO-RCS32(Y)-N4-3(B), Aeocky | RHEA PRO-RCS50(Y)-N4-3-25, Aeocky | RHEA-RCS25(Y)-N4-3-25, Aeocky | RHEA-RCS32(Y)-N4-3, AERIC | AERD501P, and 506 more (the calculator lists them all)
A10 New Manual Rating Basis (required) Conditional
About this input

IEF for labels from June 2019, EF for earlier ones. Unknown, the default, flags that the two figures may not be on the same test (DESIGN r1.5).

Default Unknown Allowed IEF (label from June 2019 or later), EF (earlier label), Unknown

Outputs

A10 PV Replace End Of Life
About this output

Present value of replacing when the old unit fails. Blank when not evaluated.

Unit $
A10 PV Keep
About this output

Present value of keeping the old unit at the discount rate.

Unit $
A10 Replace Now Verdict
About this output

The comparison of replacing now with keeping, in words.

No unit declared
A10 PV Replace Now
About this output

Present value of replacing now at the discount rate.

Unit $
A10 Old Rated Figure
About this output

Old unit: The efficiency used for the unit: its rating, the federal minimum for the year it was made, or your figure.

Unit L/kWh
A10 Old Annual Total Cost
About this output

Old unit: Electricity and upkeep in year 1.

Unit $/yr
A10 Old Annual KWh
About this output

Old unit: The water the old unit removes in a year divided by this unit's efficiency.

Unit kWh/yr
A10 Old Model Card
About this output

Old unit: The unit as the calculator reads it: type, year, capacity, efficiency and its rating basis, and the record it came from.

No unit declared
A10 Old Annual Upkeep
About this output

Old unit: The yearly upkeep you entered for the unit.

Unit $/yr
A10 Self Check
About this output

Whether the model's internal consistency checks hold.

No unit declared
A10 Total Replace Now
About this output

Net initial cost plus the new unit's running cost over the years compared, less the value left at the end, without discounting.

Unit $
A10 Total Replace End Of Life
About this output

Keep the old unit until it fails, then buy the new one at today's price. Blank when no remaining life below the period is given.

Unit $
Model Status
About this output

OK, CHECK with a reason to read, or NOT VALID with what to fix.

No unit declared
A10 Water Removed Pints
About this output

The old unit's capacity times the hours it runs, divided by 24; the new unit is assumed to remove the same water.

Unit pints/yr
A10 Total Keep
About this output

Running cost of keeping the old unit over the years compared, without discounting.

Unit $
A10 Simple Payback Text
About this output

The simple payback in words: the years, no payback, or a missing price.

No unit declared
A10 Sensitivity Savings
About this output

Money saved in year 1 at 250 to 8,760 hours a year (rows) and 50% to 150% of the electricity price used (columns).

No unit declared
A10 Status Code
About this output

The deciding reason of the status line as a short code, OK when nothing applies.

No unit declared
A10 Simple Payback Years
About this output

Net initial cost divided by the money saved in year 1. Blank when nothing is saved or the price is missing.

Unit years
A10 Electricity Rate Note
About this output

Where the electricity price comes from: the EIA state average and its year, or your own price.

No unit declared
A10 Discounted Payback Year
About this output

The first year in which the cumulative discounted net benefit of replacing now reaches zero. Blank when it does not within the years compared.

Unit year
A10 End Of Life Verdict
About this output

The comparison of replacing now with waiting until the old unit fails, in words.

No unit declared
A10 Electricity Rate Used
About this output

The electricity price in the sums: your own, or the state average.

Unit $/kWh
A10 Discounted Payback Text
About this output

The discounted payback in words.

No unit declared
A10 Annual Savings USD
About this output

Old minus new running cost in year 1; negative means the new unit costs more to run.

Unit $/yr
A10 Annual Energy Savings KWh
About this output

Old minus new electricity a year; negative means the new unit uses more.

Unit kWh/yr
A10 Data Vintage Note
About this output

The sources and their dates.

No unit declared
A10 Cash Flow
About this output

Year-by-year costs of keeping, replacing now and replacing at end of life, the net benefit of replacing now, and its cumulative and discounted values. Rows past the years compared are blank.

No unit declared
A10 Net Initial Cost
About this output

Price, sales tax, installation and disposal, less incentives and the old unit's sale value.

Unit $
A10 New Run Hours
About this output

Hours a year the new unit needs to remove the same water. Blank when its capacity is zero.

Unit hours/yr
A10 New Rated Figure
About this output

New unit: The efficiency used for the unit: its rating, the federal minimum for the year it was made, or your figure.

Unit L/kWh
A10 Old Annual Energy Cost
About this output

Old unit: Electricity cost in year 1.

Unit $/yr
A10 NPV Replace Now
About this output

Present value of keeping minus that of replacing now; positive means replacing now costs less.

Unit $
A10 New Model Card
About this output

New unit: The unit as the calculator reads it: type, year, capacity, efficiency and its rating basis, and the record it came from.

No unit declared
A10 New Annual KWh
About this output

New unit: The water the old unit removes in a year divided by this unit's efficiency.

Unit kWh/yr
A10 New Annual Energy Cost
About this output

New unit: Electricity cost in year 1.

Unit $/yr
A10 New Annual Upkeep
About this output

New unit: The yearly upkeep you entered for the unit.

Unit $/yr
A10 New Annual Total Cost
About this output

New unit: Electricity and upkeep in year 1.

Unit $/yr
This page is provided by LogicCommons for informational purposes only. Results are model outputs computed from the inputs you supply and are not financial, investment, tax, accounting, or legal advice, and no advisory relationship is created. Verify all inputs and results independently before relying on them in any decision.

LogicCommons is in beta. If a result, label, or reference looks wrong, tell us here; we read every message.

What it is

This calculator weighs keeping your dehumidifier against replacing it. Describe the old unit by picking its model from the ENERGY STAR lists, by the year it was made and its capacity, or from its capacity and efficiency. Then pick the new model and enter how many hours a year the old one runs and what you pay for electricity. It works out the water removed, each unit's yearly energy use and cost, the yearly saving, the net cost of the new unit, the paybacks, and the cost over the years you choose of keeping the old unit, replacing it now, or replacing it when it wears out.

Model figures come from federal sources only: the ENERGY STAR certified and historical lists published by the EPA, and the DOE test procedure and efficiency standards. Default electricity prices come from the EIA. You set the price of the new unit; the opening example uses an illustrative one, not a quote or a current price.

Methodology

Purpose and model boundary

This calculator compares two ways forward for a household dehumidifier: keep the unit you have, or replace it with a new one. It works out how much water the old unit removes in the hours you run it, the electricity each unit needs to remove that same water at its rated efficiency, prices it at your electricity rate, and sets the yearly saving against what the new unit costs. Over the number of years you choose, it compares keeping the old unit, replacing it now and, when you say how many years the old unit has left, replacing it when it wears out.

Every figure on this page is computed by the spreadsheet; the page adds nothing to it. The model covers running cost and purchase cost only. It does not judge performance, noise, size or reliability, and it does not price financing, warranties or your own time.

Inputs and units

  • The old dehumidifier, described in one of four ways:
    • a model from the ENERGY STAR historical lists (Versions 3, 4 and 5);
    • a model from the current ENERGY STAR list;
    • the year it was made, its class (portable or whole-home) and its capacity in pints a day, plus the case volume of a whole-home unit made from 2019: the calculator then uses the lowest efficiency the federal standard allowed for that year and size;
    • manual entry: its capacity in pints a day, its efficiency in liters per kWh and the rating basis (IEF for labels from June 2019, EF before, or Unknown, where it starts).
  • Type: Portable or Whole-home, for each unit. For a listed model, choose the type first, then pick the model from that type's list. Each entry reads "Brand | Model number", exactly as ENERGY STAR lists it.
  • The new dehumidifier: a model from the current ENERGY STAR list, or manual entry as for the old unit, and its price, more than $0 and at most $10,000. The price is always yours to set; the examples use round illustrative prices, not quotes.
  • Use: the hours a year your current dehumidifier runs removing water, 0 to 8,760. The default is 1,095, the hours the DOE test procedure assumes.
  • Electricity price, optional: the state, which sets the default price, or your own price in dollars per kWh.
  • Purchase and upkeep: installation, removal and disposal of the old unit, sales tax on the price, verified rebates, the sale or scrap value of the old unit, and yearly upkeep for each unit. Each is optional and counts as zero when left blank.
  • The comparison: the years to compare (1 to 30), the yearly change in electricity prices, the discount rate, and, optionally, the years the old unit has left and the expected life of the new unit.

Capacity is in US pints a day (a US pint is 0.473176473 liters), efficiency in liters per kWh, energy in kWh a year and money in dollars.

Governing relationships

The water you remove. The old unit's capacity in liters a day × the hours it runs ÷ 24 gives the water it removes in a year. The calculator assumes the new unit removes the same water.

Energy. Each unit's yearly kWh is that water ÷ its efficiency in liters per kWh. For the old unit this is its capacity ÷ its efficiency × its hours. The new unit runs water × 24 ÷ its capacity hours; if that is more than 8,760 hours a year, the new unit is too small for the load, and the status says so.

Two test procedures. Units listed before the Version 5 list are rated by energy factor (EF) under DOE Appendix X, with capacity measured at 80 °F; Version 5 and current units by integrated energy factor (IEF) under Appendix X1, at 65 °F, which gives a lower capacity for the same unit. When the old and new units are rated on different bases, the old unit's energy, and the saving, are probably understated, and the status says so.

A unit described by the year it was made.

  • No DOE study gives the typical efficiency of dehumidifiers by year made, so the calculator uses the lowest efficiency the federal standard allowed for that year and capacity band (10 CFR 430.32(v)): minimum EF from 2007-10-01 and 2012-10-01, minimum IEF from 2019-06-13. That is the most energy such a unit could use: your unit may use less, and the saving may be overstated.
  • A year in which the standard changed part-way uses the standard in force on 1 January of that year. A unit made before 2008 is entered manually: there was no federal limit before 2007-10-01.

Yearly cost. For each dehumidifier, the yearly running cost is its yearly kWh times the electricity price; adding yearly upkeep gives its yearly cost, and the yearly saving is the old dehumidifier's yearly cost less the new one's.

Electricity price. Your own price, when you enter one, is used; otherwise the average residential price for the state you choose.

Purchase cost. The capital cost is the price × (1 + sales tax rate) + installation − rebates. The net initial cost adds removal and disposal and takes off the old unit's sale value.

Payback. Simple payback is the net initial cost ÷ the first year's saving, when the saving is positive; otherwise there is no payback. Discounted payback is the first year in which the cumulative discounted net benefit of replacing now reaches zero within the years compared.

The three paths over the years compared. Electricity prices change each year by the rate you enter; upkeep stays flat; costs fall at the end of each year and are discounted at your rate.

  • Keep: the old unit's yearly cost every year.
  • Replace now: the net initial cost today, then the new unit's yearly cost, less the value left in the new unit at the end.
  • Replace at end of life (when you enter the years the old unit has left and they are fewer than the years compared): the old unit's yearly cost until it fails, then the capital cost and disposal in that year, then the new unit's yearly cost, less the value left in the new unit at the end.

The value left in the new unit at the end is its capital cost × the share of its expected life still remaining, on a straight line; with no expected life entered, no value is counted. The net present value of replacing now is the present cost of keeping less the present cost of replacing now: positive means replacing now costs less.

Calculation sequence

The spreadsheet first finds each unit's rated figure from the list, the federal standard for the year made or your entries, and checks the inputs. It then reduces each unit to a yearly energy figure that scales with your use, and from it computes the yearly kWh, the yearly costs and the saving. The purchase cost, the paybacks, the present values of the three paths and the year-by-year cash flow follow. The sensitivity table uses the same per-unit figures, so it cannot disagree with the main result. A block of consistency checks, including that the discounted cash flow reaches the same net present value as the closed-form formula, runs before the status is returned.

Outputs and interpretation

The headline is the yearly saving from replacing the old dehumidifier, with the simple payback and the net present value of replacing now. For each unit the results give its rated figure, its yearly kWh, and its yearly energy, upkeep and total cost, with the electricity price actually used and a note on where it came from. The decision results give the net initial cost, the discounted payback year, the total and present cost of keeping, of replacing now and of replacing at end of life, and a plain verdict on each.

The results also give the water the old unit removes in a year, in pints, and the hours the new unit needs to remove it.

The cash-flow table shows each year from 0 to the years compared: the cost of each path, the net benefit of replacing now, and its cumulative, discounted and cumulative discounted values. The sensitivity table shows the yearly saving at 250, 500, 750, 1,095, 1,500, 2,190, 4,380 and 8,760 hours a year, and at 0.5, 0.75, 1, 1.25 and 1.5 times the electricity price used.

A model card beside each pick shows the model's type, capacity, efficiency and its rating basis, and the year it was listed or became available.

The first chart, “Cumulative net benefit of replacing now, by year”, shows Undiscounted and Discounted by year. The second chart, “Cost over the years compared”, shows Total and Present value by option. The third chart, “Running cost in year 1”, shows Electricity and Upkeep by unit, stacked.

Validation and status logic

The workbook returns one status, chosen in this order: NOT VALID, then CHECK, then OK.

  • NOT VALID names the first problem: a source that is not one of its options; a listed model that is not in its list or whose type differs from the type chosen, or, for a unit described by the year made, no class or year (before 2008); a capacity missing or outside 0 to 300 pints a day, a whole-home case volume missing or outside 0 to 50 cubic feet, or no federal band for them; a manual capacity outside 0 to 300 pints a day or a manual efficiency outside 0 to 10 liters per kWh; a manual rating basis that is not one of its options; an upkeep figure outside 0 to $5,000 a year; hours a year missing or outside 0 to 8,760; no electricity price, or your own price outside $0.01 to $2.00 per kWh; a price for the new unit that is missing, not above $0 or above $10,000; another money or rate input outside its range; years to compare that are not a whole number from 1 to 30, or a growth or discount rate outside its range; years left that are not a whole number from 0 to 30, or an expected life that is not a whole number from 1 to 40. NOT VALID is a refusal, not a numeric answer: every figure reads zero and is withheld.
  • CHECK accompanies a computed result that needs the stated review: an old unit described by the year it was made, so its figure is the federal limit for that year: your unit may use less and the saving may be overstated; a manual entry whose rating basis is Unknown; one unit rated by EF and the other by IEF, so the old unit's energy and the saving are probably understated; old and new units of different types (portable and whole-home); a new unit that would need more than 8,760 hours a year to remove the same water; zero hours a year; a new unit that does not cost less to run than the old one at your use, so there is no payback; or an old unit with fewer years left than the years compared, so the end-of-life path is the realistic one.
  • OK otherwise.

Assumptions and limitations

  • The new unit removes the same water as the old one. The moisture load is set by the old unit's capacity and your hours; a bigger new unit runs fewer hours, not more water.
  • 1,095 hours is the test basis, not your use. DOE's Appendix X1 counts 1,095 dehumidification-mode hours a year; your use enters only through the hours you set.
  • The historical lists are snapshots. They hold the models listed when each ENERGY STAR specification changed; models in between are missing, the oldest list (Version 2) is not used, and older lists do not say whether a unit is portable or whole-home, so those units are treated as portable.
  • The federal minimum efficiency is a floor, not a measurement. A unit described by the year it was made may use less energy, so the saving may be overstated.
  • Expected life. No federal lifetime for dehumidifiers was found; enter the new unit's expected life if you want the value left in it at the end to count.
  • The default electricity price is an average. It is the EIA's annual average residential price for the state, not your tariff. Enter your own price from your bill for a better answer.
  • One price change rate applies to electricity in every year. The future purchase in the end-of-life path is priced at today's price.
  • There is no loan, no depreciation other than the value left in the new unit at the end, and no resale other than the old unit's sale value when it is replaced now.

Data and vintage

The model lists and the federal standards are reviewed reference tables inside the workbook, refreshed from their federal publishers; their version is shown in the result details.

  • Current models: the ENERGY STAR certified dehumidifiers dataset (EPA), Version 6.0, 571 records downloaded 2026-10-28 (portable 547, whole-home 24). Where a model is listed more than once, the most recent listing is used.
  • Historical models: the ENERGY STAR Version 5 list (713 records, IEF), the Version 4 list (649, EF; 210 with no efficiency are left out) and the Version 3 list (396, EF), downloaded 2026-10-28.
  • Year made: the federal minimum efficiency by capacity band from 10 CFR 430.32(v), from 2007-10-01, 2012-10-01 and 2019-06-13.
  • Default electricity prices: EIA 2025 annual average residential electricity prices by state (Form EIA-861).

Worked examples and prices

Prices are not part of the reference data: the price of the new unit is an input you set. The opening example and the five worked examples each use an illustrative price for the new unit, so that the example computes, and each says so: “Illustrative price for this example, not a quote or a current price. Prices vary: check current prices online or enter your own.”

Restrictions and non-computing states

The calculator enforces its numeric and choice limits before it accepts a result. A model that is not in its list or does not match the type chosen, a unit made before the first federal standard described by its year, a manual unit with no capacity or efficiency and a missing price for the new unit are refused by the workbook.

Errors and warnings

A request rejected by the page's input limits is not a computed result. A transport or service failure, a timeout or a cancelled run cannot establish a fresh workbook answer, and the last result stays on the page marked as out of date. Check your unit's EnergyGuide label or nameplate and your own bills before relying on a result for a purchase.

References

Sources and further reading

The calculator reads its model lists, its federal limits and its default electricity prices from reviewed reference tables inside the workbook, by record, with their version shown in the result details. Every table comes from a US federal source. The sources below publish the data and the rules the model applies. They do not endorse this calculator.

This is an educational estimate of running and purchase costs for the units and prices you enter, not a product recommendation or a quote. The ENERGY STAR lists show each model's rated use under the DOE test procedure, not your unit's measured use.

Frequently asked questions

Why does the calculator assume the new unit removes the same water?
Because the dampness in your home does not change when you change the machine. A larger new unit removes that water in fewer hours; the saving comes from removing each liter with less electricity.
How many hours should I enter?
The hours your current unit actually runs removing water in a year. If you do not know, the default is 1,095 hours, the figure the DOE test procedure assumes; your season may be shorter or longer.
My old unit is rated by EF and the new one by IEF. Are they comparable?
Not exactly. EF was measured at 80 °F and IEF at 65 °F, which gives lower capacity and efficiency numbers for the same unit. The calculator uses each figure as rated and warns that the saving is probably understated.
My model number is not in the list. What should I do?
Describe it by the year it was made, its class and its capacity, which uses the lowest efficiency the federal standard allowed for that year, or enter its capacity and efficiency from its label or manual.
Where does the new unit's price come from?
You set it. Prices are not part of the calculator's reference data. The opening example and the worked examples use a round illustrative price for their new unit only so that they compute, and each says so: it is an illustrative price for that example, not a quote or a current price. Prices vary, so check current prices online or enter your own.
Is the electricity price my actual rate?
No. The default is the EIA's 2025 average residential electricity price for your state. Enter the price from your own bill for a better answer.
Results are informational and not professional advice. See our Terms of Use. Powered by SpreadsheetWeb · About · Privacy · Terms