Home And Transportation Savings

Heat Pump Upgrade Calculator

Compare keeping your heat pump with replacing it: yearly cooling and heating electricity, running cost, payback, and the cost over the years you choose. Estimates for planning, not financial advice.

Last updated

How to Use the Heat Pump Upgrade Calculator: Keep Your Old Heat Pump or Replace It?

Plays from YouTube. Close the video to keep working on your drawing.

Calculator overview

Inputs and outputs

This summary comes from the calculator's published input and output contract.

Inputs

A08 Old Maintenance
When omitted Blank
About this input

Service or repairs you expect each year if you keep the old heat pump.

Unit $/yr Default Not set Range 0 to 5000
A08 Old Heating KWh (required) Conditional
About this input

The electricity the old heat pump uses for heating in a year, backup strips included. More than 0.

Unit kWh/yr Default 8000 Range 0 to 100000
A08 Old Manual Rating Basis (required) Conditional
About this input

SEER / HSPF (rated before 2023) figures are converted to the 2023 SEER2 / HSPF2 basis with DOE's ratios for the class. Unknown uses them as given, and the status says savings are probably understated.

Default SEER / HSPF (rated before 2023) Allowed SEER2 / HSPF2 (rated 2023 or later), SEER / HSPF (rated before 2023), Unknown
A08 Old Manual HSPF (required) Conditional
About this input

The seasonal heating rating from the same source.

Unit Btu/Wh Default 8.2 Range 4 to 20
A08 Old Curr Model Split (required) Conditional
About this input

For an old heat pump that is still ENERGY STAR certified: brand and outdoor unit as listed today. The lowest SEER2 and HSPF2 of its certified combinations are used.

Default 1HVAC | ACIQ-12-EHPB Allowed 1HVAC | ACIQ-12-EHPB, 1HVAC | ACIQ-12-EHPD, 1HVAC | ACIQ-18-EHPD, 1HVAC | ACIQ-18-HPB, 1HVAC | ACIQ-18-HPD, 1HVAC | ACIQ-18ZPL-HP230B, 1HVAC | ACIQ-24-EHPB, 1HVAC | ACIQ-24-EHPD, 1HVAC | ACIQ-24-HP32, 1HVAC | ACIQ-24-HPB, and 4,581 more (the calculator lists them all)
A08 Old Cooling KWh (required) Conditional
About this input

The electricity the old heat pump uses for cooling in a year: your summer bills minus a month with no heating or cooling, for example. More than 0.

Unit kWh/yr Default 3000 Range 0 to 50000
A08 New Type (required)
About this input

Ducted split (uses ducts), ductless mini or multi-split, or single package. It chooses which model list is shown.

Default Ducted split Allowed Ducted split, Ductless mini/multi-split, Single package
A08 Old Curr Model Pkg (required) Conditional
About this input

For an old heat pump that is still ENERGY STAR certified: brand and outdoor unit as listed today. The lowest SEER2 and HSPF2 of its certified combinations are used.

Default 1HVAC | ACIQ-PHH1748000K000V Allowed 1HVAC | ACIQ-PHH1748000K000V, 1HVAC | ACIQ-PHH1760000K000V, AC PRO | AK-H04TC/NAA-T(U), AC PRO | AK-H05TC/NAA-T(U), AC PRO | PKHP-X-024VBC, AC PRO | PKHP-X-036VBC, AC PRO | PKHP-X-048VBC, AC PRO | PKHP-X-060VBC, ACIQ | ACIQ-PHH1748000K000V, ACIQ | ACIQ-PHH1760000K000V, and 820 more (the calculator lists them all)
A08 Old Curr Model Mini (required) Conditional
About this input

For an old heat pump that is still ENERGY STAR certified: brand and outdoor unit as listed today. The lowest SEER2 and HSPF2 of its certified combinations are used.

Default 1HVAC | ACIQ-06ZPL-HP230B Allowed 1HVAC | ACIQ-06ZPL-HP230B, 1HVAC | ACIQ-06ZPL-HP230C, 1HVAC | ACIQ-09Z-HP115B, 1HVAC | ACIQ-09Z-HP115C, 1HVAC | ACIQ-09Z-HP230C, 1HVAC | ACIQ-09ZPL-HP230B, 1HVAC | ACIQ-09ZPL-HP230C, 1HVAC | ACIQ-09ZS-HP115C, 1HVAC | ACIQ-09ZS-HP230C, 1HVAC | ACIQ-12ZPL-HP230B, and 7,091 more (the calculator lists them all)
A08 Old Manual SEER (required) Conditional
About this input

The seasonal cooling rating from the nameplate, the yellow EnergyGuide label or the AHRI certificate.

Unit Btu/Wh Default 14 Range 6 to 40
A08 Sales Tax Rate
When omitted Blank
About this input

Applied to the installed price only.

Default Not set Range 0 to 0.15
A08 Rate Growth (required)
About this input

Applied to electricity prices alike. 0% means flat prices.

Default 0.02 Range -0.1 to 0.15
A08 System Size Tons (required)
About this input

The nominal size of the heat pump (12,000 Btu/h per ton), from its nameplate or model number. The estimate route uses it as the home's design load.

Unit tons Default 3 Range 0.5 to 6
A08 State (required)
About this input

USPS state code, or US for the national average. It sets the default electricity price (a state average, not your tariff), the degree days of the estimate route and the climate checks, and the DOE region of the federal minimums.

Default US Allowed AK, AL, AR, AZ, CA, CO, CT, DC, DE, FL, GA, HI, IA, ID, IL, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, RI, SC, SD, TN, TX, UT, VA, VT, WA, WI, WV, WY, US
A08 Old Vintage (required) Conditional
About this input

When the model is not listed: the year made. The federal minimum SEER and HSPF for that class, year and your state's DOE region are used, converted to the 2023 basis for units made before 2023; your unit may be more efficient.

Default Made in 2008 Allowed Made in 1992, Made in 1993, Made in 1994, Made in 1995, Made in 1996, Made in 1997, Made in 1998, Made in 1999, Made in 2000, Made in 2001, Made in 2002, Made in 2003, Made in 2004, Made in 2005, Made in 2006, Made in 2007, Made in 2008, Made in 2009, Made in 2010, Made in 2011, Made in 2012, Made in 2013, Made in 2014, Made in 2015, Made in 2016, Made in 2017, Made in 2018, Made in 2019, Made in 2020, Made in 2021, Made in 2022, Made in 2023, Made in 2024, Made in 2025
A08 Old Sale Value
When omitted Blank
About this input

Money you receive for the old system if you replace it now.

Unit $ Default Not set Range 0 to 5000
A08 Old Remaining Life
When omitted Blank
About this input

Fills the replace-at-end-of-life comparison. Blank skips it.

Unit years Default Not set Range 0 to 30
A08 Old Type (required)
About this input

Ducted split, ductless mini or multi-split, or single package. It chooses the model list and the federal class (ductless counts as split).

Default Ducted split Allowed Ducted split, Ductless mini/multi-split, Single package
A08 Old Source (required)
About this input

Pick it from the current ENERGY STAR list if it is still listed; if not, pick the year it was made (the federal minimum for that year is used); or type its SEER and HSPF from the nameplate or AHRI certificate.

Default Manual entry Allowed Model from current ENERGY STAR list, Model not found: pick approximate age, Manual entry
A08 New Source (required)
About this input

Pick a currently certified ENERGY STAR model by its outdoor unit, or type the HSPF2 from the AHRI certificate your contractor gives you.

Default Model from current ENERGY STAR list Allowed Model from current ENERGY STAR list, Manual entry (AHRI certificate)
A08 Extra Work
When omitted Blank
About this input

Work beyond the installed price, if your quote lists it separately.

Unit $ Default Not set Range 0 to 50000
A08 Electricity Rate Override
When omitted Blank
About this input

From your bill. Overrides the state average.

Unit $/kWh Default Not set Range 0.01 to 2
A08 Horizon Years (required)
About this input

The comparison period, 1 to 30 whole years.

Unit years Default 15 Range 1 to 30
A08 HDD Override
When omitted Blank
About this input

Replaces the state's yearly heating degree day normal (base 65 deg F) in the estimate route and the cold-climate check.

Unit deg F-day Default Not set Range 0 to 20000
A08 Disposal
When omitted Blank
About this input

Removal or capping charge, if not in the quote.

Unit $ Default Not set Range 0 to 5000
A08 Backup Type (required)
About this input

HSPF2 already includes the backup heat of a moderate climate. Choose electric resistance only for extra backup heat in a colder climate; it applies to the old and the new heat pump alike.

Default None beyond the rating Allowed None beyond the rating, Electric resistance
A08 Backup Share (required) Conditional
About this input

The extra share of the yearly heat the backup supplies. Read only when a backup is chosen.

Default 0.1 Range 0 to 1
A08 Discount Rate (required)
About this input

The yearly return you could earn on the money instead. 0% means no discounting.

Default 0.03 Range 0 to 0.2
A08 CDD Override
When omitted Blank
About this input

Replaces the state's yearly cooling degree day normal in the estimate route.

Unit deg F-day Default Not set Range 0 to 6000
A08 Incentives
When omitted Blank
About this input

Only incentives you have confirmed you qualify for.

Unit $ Default Not set Range 0 to 5000
A08 New Model Mini (required) Conditional
About this input

Brand and outdoor unit model as listed by ENERGY STAR (ductless mini and multi-split). The lowest SEER2 and HSPF2 of its certified combinations are used.

Default 1HVAC | ACIQ-06ZPL-HP230B Allowed 1HVAC | ACIQ-06ZPL-HP230B, 1HVAC | ACIQ-06ZPL-HP230C, 1HVAC | ACIQ-09Z-HP115B, 1HVAC | ACIQ-09Z-HP115C, 1HVAC | ACIQ-09Z-HP230C, 1HVAC | ACIQ-09ZPL-HP230B, 1HVAC | ACIQ-09ZPL-HP230C, 1HVAC | ACIQ-09ZS-HP115C, 1HVAC | ACIQ-09ZS-HP230C, 1HVAC | ACIQ-12ZPL-HP230B, and 7,091 more (the calculator lists them all)
A08 New Manual SEER2 (required) Conditional
About this input

The cooling seasonal energy efficiency ratio (SEER2, 2023 test basis) of the matched system.

Unit Btu/Wh Default 16 Range 10 to 40
A08 New Model Split (required) Conditional
About this input

Brand and outdoor unit model as listed by ENERGY STAR. The lowest SEER2 and HSPF2 of its certified combinations are used.

Default Carrier | D5CURAH36AAK Allowed 1HVAC | ACIQ-12-EHPB, 1HVAC | ACIQ-12-EHPD, 1HVAC | ACIQ-18-EHPD, 1HVAC | ACIQ-18-HPB, 1HVAC | ACIQ-18-HPD, 1HVAC | ACIQ-18ZPL-HP230B, 1HVAC | ACIQ-24-EHPB, 1HVAC | ACIQ-24-EHPD, 1HVAC | ACIQ-24-HP32, 1HVAC | ACIQ-24-HPB, and 4,581 more (the calculator lists them all)
A08 New Model Pkg (required) Conditional
About this input

Brand and model as listed by ENERGY STAR (single package). The lowest SEER2 and HSPF2 of its certified combinations are used.

Default 1HVAC | ACIQ-PHH1748000K000V Allowed 1HVAC | ACIQ-PHH1748000K000V, 1HVAC | ACIQ-PHH1760000K000V, AC PRO | AK-H04TC/NAA-T(U), AC PRO | AK-H05TC/NAA-T(U), AC PRO | PKHP-X-024VBC, AC PRO | PKHP-X-036VBC, AC PRO | PKHP-X-048VBC, AC PRO | PKHP-X-060VBC, ACIQ | ACIQ-PHH1748000K000V, ACIQ | ACIQ-PHH1760000K000V, and 820 more (the calculator lists them all)
A08 New Manual HSPF2 (required) Conditional
About this input

The heating seasonal performance factor (HSPF2, 2023 test basis) of the matched system. Never an older HSPF figure.

Unit Btu/Wh Default 8 Range 5 to 20
A08 New Expected Life
When omitted Blank
About this input

Used only for the value left in the heat pump at the end of the period (straight line). Blank counts no value left: no lifetime is sourced for this app.

Unit years Default Not set Range 1 to 40
A08 Load Source (required)
About this input

Estimate from your state's degree days and the system size (DOE use hours), or work it back from your own yearly heating and cooling kWh.

Default Estimate from my state and system size Allowed Estimate from my state and system size, From my bills: yearly heating and cooling kWh
A08 New Maintenance
When omitted Blank
About this input

Service you expect each year for the heat pump.

Unit $/yr Default Not set Range 0 to 5000
A08 New Installed Price (required)
About this input

The installed price of the heat pump job, from your contractor's quote. The calculator never looks up a price. Illustrative price for this example, not a quote or a current price. Prices vary: check current prices online or enter your own. Get a contractor quote.

Unit $ Default 10000 Range 1 to 60000

Outputs

A08 Old Model Card
About this output

Old heat pump: The heat pump as the calculator reads it: the model and its ratings, the federal minimum for the year made, or the figures you typed, with the conversion to the 2023 basis.

No unit declared
A08 Old Eff Heating Used
About this output

Old heat pump: HSPF2, or an HSPF converted to the HSPF2 basis with DOE's ratio for the class.

Unit Btu/Wh
A08 Old Eff Cooling Used
About this output

Old heat pump: SEER2, or a SEER converted to the SEER2 basis with DOE's ratio for the class.

Unit Btu/Wh
A08 PV Replace End Of Life
About this output

Present value of replacing when the old heat pump fails. Blank when not evaluated.

Unit $
A08 PV Keep
About this output

Present value of keeping the old heat pump at the discount rate.

Unit $
A08 Old Seasonal COP Used
About this output

Old heat pump: The seasonal heating coefficient of performance: HSPF2 x 1000 / 3,412.

Unit W/W
A08 Old Annual Energy Cost
About this output

Old heat pump: Electricity cost in year 1.

Unit $/yr
A08 Old Annual Cooling KWh
About this output

Old heat pump: Electricity for cooling: the cooling load divided by SEER2 (x 1000).

Unit kWh/yr
A08 NPV Replace Now
About this output

Present value of keeping minus that of replacing now; positive means replacing now costs less.

Unit $
A08 Old Annual Total Cost
About this output

Old heat pump: Energy cost plus upkeep in year 1.

Unit $/yr
A08 Old Annual KWh
About this output

Old heat pump: Cooling plus heating electricity.

Unit kWh/yr
A08 Old Annual Heating KWh
About this output

Old heat pump: Electricity for heating: the heat pump plus any extra electric backup.

Unit kWh/yr
A08 Total Keep
About this output

Running cost of keeping the old heat pump over the years compared, without discounting.

Unit $
A08 Status Code
About this output

The deciding reason of the status line as a short code, OK when nothing applies.

No unit declared
A08 Simple Payback Years
About this output

Net initial cost divided by the money saved in year 1. Blank when nothing is saved or the price is missing.

Unit years
Model Status
About this output

OK, CHECK with a reason to read, or NOT VALID with what to fix.

No unit declared
A08 Total Replace Now
About this output

Net initial cost plus the new heat pump's running cost over the years compared, less any value left at the end, without discounting.

Unit $
A08 Total Replace End Of Life
About this output

Keep the old heat pump until it fails, then install the heat pump at today's price. Blank when no remaining life below the period is given.

Unit $
A08 Replace Now Verdict
About this output

The comparison of replacing now with keeping, in words.

No unit declared
A08 Rating Note
About this output

How the ratings are put on one basis: the conversion of an older rating, and the lowest certified combination of a listed model.

No unit declared
A08 PV Replace Now
About this output

Present value of replacing now at the discount rate.

Unit $
A08 Simple Payback Text
About this output

The simple payback in words: the years, no payback, or a missing price.

No unit declared
A08 Sensitivity Savings
About this output

Money saved in year 1 for 50% to 150% of the heating and cooling loads (rows) and 50% to 150% of the electricity price used (columns).

No unit declared
A08 Self Check
About this output

Whether the model's internal consistency checks hold.

No unit declared
A08 Discounted Payback Year
About this output

The first year in which the cumulative discounted net benefit of replacing now reaches zero. Blank when it does not within the years compared.

Unit year
A08 Discounted Payback Text
About this output

The discounted payback in words.

No unit declared
A08 Data Vintage Note
About this output

The sources and their dates.

No unit declared
A08 End Of Life Verdict
About this output

The comparison of replacing now with waiting until the old heat pump fails, in words.

No unit declared
A08 Electricity Rate Used
About this output

The electricity price in the sums: your own, or the state average.

Unit $/kWh
A08 Electricity Rate Note
About this output

Where the electricity price comes from: the EIA state average and its year, or your own price.

No unit declared
A08 Cash Flow
About this output

Year-by-year costs of keeping, replacing now and replacing at end of life, the net benefit of replacing now, and its cumulative and discounted values. Rows past the years compared are blank.

No unit declared
A08 Annual Savings USD
About this output

Old minus new running cost in year 1; negative means the heat pump costs more to run.

Unit $/yr
A08 Annual KWh Change
About this output

Old minus new electricity a year.

Unit kWh/yr
A08 Cooling Load MMBtu
About this output

Heat removed from the home in a year: estimated from the size and the state's cooling degree days, or worked back from your cooling kWh.

Unit MMBtu/yr
A08 Climate HDD Used
About this output

The yearly heating degree days used: your override or the state normal (NOAA 1991-2020).

Unit deg F-day
A08 Climate CDD Used
About this output

The yearly cooling degree days used by the estimate route. Blank on the bills route.

Unit deg F-day
A08 New Eff Cooling Used
About this output

New heat pump: SEER2, or a SEER converted to the SEER2 basis with DOE's ratio for the class.

Unit Btu/Wh
A08 New Annual Total Cost
About this output

New heat pump: Energy cost plus upkeep in year 1.

Unit $/yr
A08 New Annual KWh
About this output

New heat pump: Cooling plus heating electricity.

Unit kWh/yr
A08 New Seasonal COP Used
About this output

New heat pump: The seasonal heating coefficient of performance: HSPF2 x 1000 / 3,412.

Unit W/W
A08 New Model Card
About this output

New heat pump: The heat pump as the calculator reads it: the model and its ratings, the federal minimum for the year made, or the figures you typed, with the conversion to the 2023 basis.

No unit declared
A08 New Eff Heating Used
About this output

New heat pump: HSPF2, or an HSPF converted to the HSPF2 basis with DOE's ratio for the class.

Unit Btu/Wh
A08 Net Initial Cost
About this output

Installed price, sales tax and extra work, less incentives, plus removal, less the old system's sale value.

Unit $
A08 Load Basis Note
About this output

How the loads are worked out: from the state's degree days, the size and DOE use hours, or from your bills.

No unit declared
A08 Heating Load MMBtu
About this output

Heat the home needs in a year: estimated from the size and the state's heating degree days, or worked back from your heating kWh.

Unit MMBtu/yr
A08 New Annual Heating KWh
About this output

New heat pump: Electricity for heating: the heat pump plus any extra electric backup.

Unit kWh/yr
A08 New Annual Energy Cost
About this output

New heat pump: Electricity cost in year 1.

Unit $/yr
A08 New Annual Cooling KWh
About this output

New heat pump: Electricity for cooling: the cooling load divided by SEER2 (x 1000).

Unit kWh/yr
This page is provided by LogicCommons for informational purposes only. Results are model outputs computed from the inputs you supply and are not financial, investment, tax, accounting, or legal advice, and no advisory relationship is created. Verify all inputs and results independently before relying on them in any decision.

LogicCommons is in beta. If a result, label, or reference looks wrong, tell us here; we read every message.

What it is

This calculator weighs keeping your heat pump against replacing it with a new one. Describe the old heat pump by its ENERGY STAR listing, the year it was made, or the ratings on its nameplate; pick the new one from the ENERGY STAR list or enter its ratings; and give your system size and state, or your old heat pump's yearly electricity from your bills. It works out your heating and cooling need, each heat pump's yearly electricity and cost, the yearly saving, the net cost of the new heat pump, the simple and discounted payback, and the cost over the years you choose of keeping the old unit, replacing it now, or replacing it when it wears out.

Equipment and climate figures come from federal sources only: ENERGY STAR (EPA), DOE efficiency standards and test procedures, NOAA climate normals and EIA electricity prices. Older and newer ratings are never mixed. You set the installed price; the opening example and each worked example carry a round illustrative price, labelled as such.

Methodology

Purpose and model boundary

This calculator compares keeping the heat pump you have with replacing it with a new one. It works out the heating and cooling your home needs, from your bills or from your state's climate and your system's size, the electricity each heat pump needs to deliver them, and the cost at your electricity price, and sets the yearly saving against what the new heat pump costs installed. Over the number of years you choose, it compares keeping the old heat pump, replacing it now and, when you say how many years the old one has left, replacing it when it wears out.

Every figure on this page is computed by the spreadsheet; the page adds nothing to it. It covers running cost and purchase cost only, for the same ducts or indoor units; a change of distribution system is not modelled.

Inputs and units

  • The old heat pump, described in one of three ways: a model from the current ENERGY STAR list, if it is still listed; the year it was made, for which the calculator uses the federal minimum ratings for your state's region; or its SEER and HSPF from the nameplate or AHRI certificate (SEER 6 to 40, HSPF 4 to 20), with the basis of those ratings: SEER2 and HSPF2 (rated 2023 or later), SEER and HSPF (rated before 2023), or Unknown.
  • Type: ducted split, ductless mini or multi-split, or single package, for each heat pump. For a listed model, choose the type first, then pick the model from that type's list, where each entry reads "Brand | Outdoor model".
  • Your heating and cooling need: the size of your system, 0.5 to 6 tons, and where the need comes from: an estimate from your state and system size, or your old heat pump's yearly cooling and heating electricity from your bills. Optionally, your own heating and cooling degree days, which replace your state's figures.
  • Backup heat: none beyond the rating, or electric resistance, with the share of the year's heat it supplies, from 0 to 1. The same share applies to the old and the new heat pump.
  • The new heat pump: a model from the current ENERGY STAR list, or the SEER2 (10 to 40) and HSPF2 (5 to 20) from its AHRI certificate.
  • Price: the state, which sets the default electricity price, and your own electricity price in dollars per kWh (0.01 to 2.00), optional.
  • Purchase and finance: the installed price of the new heat pump, which is always yours to set; extra work such as permits, electrical or duct work; sales tax; verified incentives; removal; the old unit's sale value; yearly upkeep of each unit; the years the old unit has left; the new unit's expected life; the yearly change in electricity prices; the discount rate; and the years to compare.

Heating and cooling needs are in million Btu (MMBtu) a year of heat delivered or removed. Electricity is in kWh, fuel in US gallons or therms, efficiency ratings in Btu per watt-hour (CEER, SEER2, HSPF2) or as a fraction (AFUE), and money in dollars.

Governing relationships

  • Estimated need: cooling need = system size (tons x 12,000 Btu/h) x 1,000 cooling hours x your state's cooling degree days / the US figure; heating need = system size x 2,080 heating hours x 0.77 x your state's heating degree days / the US figure. The 1,000 and 2,080 hours and the 0.77 adjustment are DOE's representative use cycles from the 2016 edition of its test-procedure rule, where the heating hours apply to a heat pump's Region IV design heating requirement. Two steps are this calculator's own, labelled approximations: that requirement is taken equal to your system's nominal size, and the national hours are scaled by your state's degree days.
  • Need from your bills: your old heat pump's yearly cooling and heating electricity are turned back into the heat it moved, using its own ratings.
  • Older and newer ratings are not mixed. A SEER or HSPF rating from before 2023 is put on the SEER2 and HSPF2 basis with the exact ratio of DOE's equivalent standard levels for its product class, from DOE's January 2017 direct final rule (82 FR 1786): for a split heat pump, 14.3/15 for SEER and 7.5/8.8 for HSPF. Those ratios translate standard levels, so applying them to one old unit is an approximation, and the rating note says so. With an Unknown basis the old rating is used as it stands, which makes the old unit look more efficient than it is, so the saving is understated.
  • Electricity: cooling kWh = cooling need in Btu / (SEER2 x 1000); heating kWh = heating need / (HSPF2 x 1000), which equals dividing by a seasonal COP of HSPF2 x 1000 / 3,412.
  • Backup heat: HSPF2 already includes the electric resistance heat a heat pump needs in DOE's moderate rating climate (Region IV), so the backup share is extra heat beyond that, supplied at 3,412 Btu per kWh, for both heat pumps.
  • Yearly cost = electricity x electricity price + upkeep; the yearly saving is the old cost minus the new cost. Payback and present value follow the rules shared with the other replacement calculators, with nothing counted twice.

Calculation sequence

The spreadsheet first checks the inputs and finds each heat pump's ratings, the climate figures and the electricity price. It works out the heating and cooling need once, shared by both heat pumps, reduces each heat pump to the electricity it uses per million Btu of heating and of cooling, and from those computes the yearly electricity, costs and saving; the purchase cost, the paybacks, the present values and the year-by-year cash flow follow. The sensitivity table uses the same per-MMBtu figures, so it cannot disagree with the main result. Consistency checks, including that your bills are reproduced from the computed need on the bills route and that the discounted cash flow reaches the same net present value as the closed-form formula, run before the status is returned.

Outputs and interpretation

The results show the yearly heating and cooling need, the degree days used, and for each heat pump the ratings used (after any conversion), the yearly cooling and heating electricity, and the yearly energy and total cost; then the yearly saving in dollars and kWh, the net cost of the new heat pump, the simple and discounted payback, and the cost of each path. A note states where the need came from (your state's degree days and DOE use hours, or your bills) and another whether an old rating was converted.

The cash-flow table shows each year of the years compared: the cost of each path, the net benefit of replacing now, and its cumulative, discounted and cumulative discounted values. The sensitivity table shows the yearly saving with the heating and cooling need scaled by 0.50, 0.75, 1.00, 1.25 and 1.50, at the same multiples of the electricity price used.

A model card beside each listed pick shows the range of its ratings across the indoor units it is certified with, whether ENERGY STAR lists it as cold-climate, and its heating capacity. The calculator uses the lowest SEER2 and HSPF2 among those pairings, so it does not credit a better pairing than the one you may buy.

The first chart, “Cumulative net benefit of replacing now, by year”, shows Undiscounted and Discounted by year. The second chart, “Cost over the years compared”, shows Total and Present value by option. The third chart, “Running cost in year 1”, shows Cooling electricity, Heating electricity and Upkeep by system, stacked.

Validation and status logic

The workbook returns one status, chosen in this order: NOT VALID, then CHECK, then OK.

  • NOT VALID names the first problem: an old-unit source or type that is not one of its options; a listed model that is not in its list or does not match the type chosen, or no federal minimum on file for that type, region and year made, in which case use the nameplate rating; a manual SEER or HSPF missing or outside its limits, or a rating basis that is not one of its options; a system size missing or outside 0.5 to 6 tons; the same problems for the new heat pump; a source of the need that is not one of its options, or a bills figure missing or outside its limits; the estimate needs degree days and your state has no figure and you have not entered your own; a backup choice that is not one of its options, or a backup share outside 0 to 1; no electricity price, or your own outside 0.01 to 2.00 dollars per kWh; a missing installed price, or one outside its limits; a money amount, the years compared, the price change, the discount rate or a life in years outside its limits. NOT VALID is a refusal, not a numeric answer: every figure reads zero and is withheld.
  • CHECK accompanies a computed result that needs the stated review: the old ratings are the federal minimum for the year made; the old unit may be more efficient, so the saving may be overstated; an old SEER or HSPF rating with an Unknown basis, or with no conversion ratio for its class, is used as if it were SEER2 or HSPF2, so the saving is probably understated; a cold state (6,000 heating degree days or more), a new heat pump ENERGY STAR does not list as cold-climate, and no backup heat beyond the rating: the HSPF2 rating assumes a moderate climate, so real seasonal efficiency will be lower; on the bills route with no backup heat, the new heat pump's capacity at your coldest month's average temperature is below that month's average heating load; zero heating and cooling electricity on the bills route; no yearly saving, so there is no payback; the old unit's remaining life is shorter than the years compared, so read the end-of-life comparison.
  • OK otherwise.

Assumptions and limitations

  • Three labelled approximations. The figures behind them are DOE's, but how this calculator applies them is its own: DOE's standard-level ratios are applied to one old unit's SEER and HSPF; DOE's heating hours, which belong to a design heating requirement, are applied to your system's nominal size; and the national hours are scaled by your state's degree days. Your bills route avoids the last two, and a rating on the SEER2 and HSPF2 basis avoids the first.
  • Not modelled: adjusting your bills for a mild or harsh year, solar and internal heat gains beyond what the degree-day base implies, humidity removal beyond the SEER2 test, and duct changes.
  • A federal minimum is a floor, not a measurement. An old unit described by the year it was made may be more efficient than the minimum, so the saving may be overstated. Where the minimum changed during a year, the newer, higher minimum is used, which keeps the saving on the low side. Wear with age is not modelled.
  • Inputs with no federal source are your assumptions: the installed price and any backup share beyond the rating. The cold-state threshold of 6,000 heating degree days is a design choice that only sets a warning.
  • Alaska, Hawaii and DC. NOAA publishes no statewide degree-day normals for any of the three. DC uses Maryland's figures; Alaska and Hawaii each use one NOAA station normal, at the Anchorage and Honolulu airports, labelled as a single station. Your own degree days replace any state figure, and the bills route works everywhere.
  • Prices. The installed price of the new heat pump is always your input; the workbook holds no price table. The opening example and each worked example carry a round illustrative price so that they compute, with the note: "Illustrative price for this example, not a quote or a current price. Prices vary: check current prices online or enter your own. Get a contractor quote."
  • The default electricity price is a state average. Your own price from your bill overrides it.

Data and vintage

  • Heat pumps: the ENERGY STAR certified air-source heat pump list (EPA), current certifications, one entry per outdoor unit sold in the US, each with the lowest SEER2 and HSPF2 among its certified indoor-unit pairings.
  • Federal minimum ratings by year made and region: DOE energy conservation standards (10 CFR 430.32), with earlier editions of the Code of Federal Regulations (1997 and 2012) for the years before the current standard.
  • Rating ratios and use hours: DOE's January 2017 direct final rule (82 FR 1786) for the SEER and HSPF level ratios, and the 2016 edition of 10 CFR 430.23 for the representative use hours.
  • Climate: NOAA NCEI statewide heating and cooling degree-day normals for 1991-2020 (nClimDiv); the US figure covers the 48 contiguous states. NOAA calls these long-term averages rather than official normals, and its notes state neither the base temperature nor the weighting.
  • Default price: EIA final 2025 average residential electricity prices by state (Form EIA-861).

Worked examples and prices

Prices are not part of the reference data: the price of the new unit is an input you set. The opening example and the five worked examples each use an illustrative price for the new unit, so that the example computes, and each says so: “Illustrative price for this example, not a quote or a current price. Prices vary: check current prices online or enter your own.”

Restrictions and non-computing states

The calculator enforces its numeric and choice limits before it accepts a result. A listed model that is not in its list or does not match the type chosen, a rating or quantity outside its limits, a missing installed price, and a missing electricity or fuel price where no default exists are refused by the workbook.

Errors and warnings

A request rejected by the page's input limits is not a computed result. A transport or service failure, a timeout or a cancelled run cannot establish a fresh workbook answer, and the last result stays on the page marked as out of date. Check your equipment's nameplate or AHRI certificate and your own bills before relying on a result for a purchase, and get a contractor quote for the installed price.

References

Sources and further reading

The calculator reads its model lists, its federal minimum ratings, its climate figures and its default energy prices from reviewed reference tables inside the workbook, with their version shown in the result details. Every table comes from a US federal source. The sources below publish the data and the rules the model applies. They do not endorse this calculator.

This is an educational estimate of running and purchase costs for the equipment and prices you enter, not a product recommendation or a quote. Ratings are measured under federal test procedures, not in your home.

Frequently asked questions

What is the difference between SEER and SEER2, or HSPF and HSPF2?
SEER2 and HSPF2 come from DOE's updated test (appendix M1), used for ratings from 2023; SEER and HSPF come from the earlier test (appendix M). The same unit rates lower on SEER2 and HSPF2, so the two cannot be compared directly. The calculator converts an older rating with the ratio of DOE's equivalent standard levels for its product class, a labelled approximation for one unit; with an Unknown basis it uses the rating as it stands, which understates your saving.
Should I use my bills or the estimate?
Your bills, when you can separate the heat pump's cooling and heating use: they measure your home directly and need neither DOE's national hours nor the degree-day scaling. The estimate is for when you cannot.
I live in Alaska or Hawaii. Which climate figures does the estimate use?
NOAA publishes no statewide degree-day normals for Alaska or Hawaii, so the estimate uses one NOAA station normal each, at the Anchorage and Honolulu airports, labelled as a single station. If those do not fit your location, enter your own degree days or use the bills route.
Does the HSPF2 rating hold in a cold winter?
HSPF2 is measured for DOE's moderate rating climate (Region IV) and already includes the electric backup heat needed there. In a colder state real seasonal efficiency is lower: choose a model ENERGY STAR lists as cold-climate, or add a backup share. The calculator warns when your state is cold and neither is set.
Why is the model's rating the lowest of a range?
A split heat pump's rating belongs to the outdoor unit paired with a particular indoor unit, and ENERGY STAR certifies many pairings. The list holds one entry per outdoor unit with the lowest SEER2 and HSPF2 among its pairings, and the model card shows the range. If your contractor quotes a specific pairing, enter its ratings from the AHRI certificate instead.
Results are informational and not professional advice. See our Terms of Use. Powered by SpreadsheetWeb · About · Privacy · Terms