Calculator overview
Inputs and outputs
This summary comes from the calculator's published input and output contract.
Inputs
- Regenerator effectiveness (required)
-
Default 0.8 Range 0 to 1
About this input
eps, the temperature effectiveness of the regenerator, from 0 to 1 (1 is the ideal regenerator). Checked whatever the configuration; used only by the two regenerated configurations, and only while the exhaust is hotter than the compressed air.
- Pressure ratio (required)
-
Default 10 Range 1.5 to 40
About this input
r, the overall compressor pressure ratio p_high/p1, from 1.5 to 40. Two-stage machines split it equally, SQRT(r) per stage.
- Lowest net work (required)
-
Unit kJ/kg Default 0 Range 0 to 600
About this input
w_min, the lowest acceptable net work of a searched design, in kJ/kg, from 0 to 600.
- Turbine inlet temperature (required)
-
Unit K Default 1200 Range 800 to 1800
About this input
T3, the turbine inlet temperature in K, from 800 to 1800: the hottest the turbine blades take. Reheating heats back to it.
- Turbine efficiency (required)
-
Default 1 Range 0.7 to 1
About this input
eta_t, the isentropic efficiency of each turbine stage, from 0.70 to 1.00 (1 is an ideal turbine).
- Search objective (required)
-
Default Efficiency Allowed Efficiency, Net work
About this input
What the search maximises over the pressure ratios: Efficiency (thermal efficiency) or Net work (kJ/kg).
- Compressor efficiency (required)
-
Default 1 Range 0.7 to 1
About this input
eta_c, the isentropic efficiency of each compressor stage, from 0.70 to 1.00 (1 is an ideal compressor).
- Challenge number (required)
-
Default 0 Range 0 to 5
About this input
Selects a challenge: 0 for none, 1 to 5 for a predefined challenge, which fixes the settings except the inputs it leaves to you.
- Ambient temperature (required)
-
Unit K Default 300 Range 250 to 320
About this input
T1, the compressor inlet (ambient) temperature in K, from 250 to 320. Intercooling cools back to it.
- Highest compressor exit temperature (required)
-
Unit K Default 1000 Range 400 to 1000
About this input
T2max, the highest allowed temperature at the exit of every compressor stage, in K, from 400 to 1000. Searched designs above it are rejected.
- Your prediction (challenge 1) (required)
-
Default Not yet predicted Allowed Not yet predicted, Raises it, Lowers it, No change
About this input
Challenge 1 only: your prediction of what raising the pressure ratio from 4 to 8 does to the efficiency of an ideally regenerated cycle (Raises it, Lowers it or No change). The results appear once you predict.
- Cycle configuration (required)
-
Default Simple Allowed Simple, Regenerated, Intercooled and reheated, Regenerated with intercooling and reheat
About this input
The gas-turbine configuration, chosen with the chip on the flow sheet: Simple (compressor, combustor, turbine), Regenerated (the exhaust preheats the compressed air), Intercooled and reheated (two compressor and two turbine stages) or Regenerated with intercooling and reheat (all three).
Outputs
- Model version
-
No unit declared
About this output
The model version.
- Model Status
-
No unit declared
About this output
OK, a CHECK message (a design within one part in a billion of a limit or the regenerator switch, no searched ratio meeting the limits for your configuration, or two searched ratios tied), or a NOT VALID message naming the input to fix.
- Net-work floor used
-
Unit kJ/kg
About this output
The net-work floor the calculation used, kJ/kg.
- Pressure ratio used
-
No unit declared
About this output
The pressure ratio the calculation used.
- Ideal components
-
No unit declared
About this output
Yes when both component efficiencies are 1: every process is reversible and the area inside the T-s loop is the net work.
- Formula module versions
-
No unit declared
About this output
The formula modules the model is built from, with their versions.
- Largest net work (unconstrained theory)
-
Unit kJ/kg
About this output
The largest net work without limits for your staging, from the closed form, in kJ/kg (unconstrained theory).
- Heat added
-
Unit kJ/kg
About this output
The heat added in the combustor (and the reheater, with two stages), in kJ/kg. Blank when the combustor cannot add heat.
- The refinement near the best searched ratio of your configuration: 41 ratios in steps of 0.025 (blank outside 1.5 to 40)
-
No unit declared
About this output
The refinement of your configuration near its best searched ratio: 41 ratios in steps of 0.025, the objective value and whether each meets the limits (blank outside 1.5 to 40).
- Searched ratios meeting the limits
-
No unit declared
About this output
How many of the 78 searched pressure ratios meet the limits for your configuration.
- Work-maximising pressure ratio (unconstrained theory)
-
No unit declared
About this output
The pressure ratio of the largest net work without limits, from the closed form for your staging (unconstrained theory; it may lie outside 1.5 to 40).
- Compressor exit limit used
-
Unit K
About this output
The compressor exit limit the calculation used, K.
- Heat rejected
-
Unit kJ/kg
About this output
The heat rejected to the surroundings by the exhaust (and the intercooler, with two stages), in kJ/kg; heat added less heat rejected equals the net work.
- The T-s path of your cycle: 10 points per process and a closing point (the player shows one row per frame)
-
No unit declared
About this output
The T-s path of your cycle for the diagram and the player: entropy, temperature, the state each process starts from and the process kind, 10 points per process and a closing point.
- Thermal efficiency
-
No unit declared
About this output
The thermal efficiency of your design: net work over heat added. Blank when the compressor exit is at least as hot as the turbine inlet, so the combustor cannot add heat.
- Search objective used
-
No unit declared
About this output
The search objective the calculation used.
- Turbine work
-
Unit kJ/kg
About this output
The work given by the turbine (both stages), in kJ/kg.
- Turbine inlet temperature used
-
Unit K
About this output
The turbine inlet temperature the calculation used, K.
- Turbine efficiency used
-
No unit declared
About this output
The turbine efficiency the calculation used.
- The search: efficiency and net work of every configuration at the 78 searched pressure ratios (blank where a ratio breaks a limit), with the Carnot limit
-
No unit declared
About this output
The search: for each of the 78 pressure ratios from 1.5 to 40, the efficiency and net work of every configuration (blank where the ratio breaks a limit), and the Carnot limit as a reference line.
- Pressure ratio where the regenerator stops helping (theory)
-
No unit declared
About this output
The pressure ratio where the turbine exhaust is exactly as hot as the compressed air, so a regenerator stops helping, for your staging (unconstrained theory; it may lie outside 1.5 to 40).
- Refined best value
-
No unit declared
About this output
The objective value at the refined best ratio; never below the searched best.
- Refined best pressure ratio
-
No unit declared
About this output
The best pressure ratio after refining the best searched ratio in 41 steps of 0.025 (inside 1.5 to 40).
- Margin over the runner-up ratio
-
No unit declared
About this output
How far the best searched value under the chosen objective is ahead of the second best.
- Regenerator effectiveness used
-
No unit declared
About this output
The regenerator effectiveness the calculation used.
- Regenerator bypassed
-
No unit declared
About this output
Yes when the regenerator is bypassed because the turbine exhaust is not hotter than the compressed air; blank for a configuration without one.
- Design note
-
No unit declared
About this output
What your design does: the combustor cannot add heat, the design cannot run, it breaks a limit, its regenerator is bypassed, or it runs and meets the limits.
- Pressure ratio of the best overall design
-
No unit declared
About this output
The searched pressure ratio of that best overall design.
- Most net work in the search
-
Unit kJ/kg
About this output
The most net work the search finds for your configuration under the limits, in kJ/kg.
- Pressure ratio of the most net work
-
No unit declared
About this output
The searched pressure ratio of that most net work (the lowest one when several tie).
- Share of the Carnot efficiency
-
No unit declared
About this output
Your thermal efficiency as a share of the Carnot efficiency. Blank when the combustor cannot add heat.
- Carnot efficiency
-
No unit declared
About this output
The Carnot efficiency 1 - T1/T3: the most any cycle between the two temperatures can reach.
- Best value over every configuration
-
No unit declared
About this output
The best value under the chosen objective over every configuration and searched ratio.
- Best efficiency in the search
-
No unit declared
About this output
The best thermal efficiency the search finds for your configuration under the limits.
- Best design at the edge of the range
-
No unit declared
About this output
Yes when the best searched ratio under the chosen objective is 1.5 or 40, the edge of the range: the true optimum may lie beyond it.
- Back-work ratio
-
No unit declared
About this output
Compressor work over turbine work: the share of the turbine work the compressor uses.
- Ambient temperature used
-
Unit K
About this output
The ambient temperature the calculation used, K.
- Pressure ratio of the best efficiency
-
No unit declared
About this output
The searched pressure ratio of that best efficiency (the lowest one when several tie).
- Configurations tied for best
-
No unit declared
About this output
How many configurations tie for the best value (a regenerator adds no work, so under Net work pairs always tie).
- Best configuration
-
No unit declared
About this output
The configuration with the best value under the chosen objective over every configuration; the simplest one when several tie.
- Configuration used
-
No unit declared
About this output
The configuration the calculation used (a challenge may fix it).
- Every configuration: its best searched designs and its values at your pressure ratio
-
No unit declared
About this output
Every configuration side by side: its best searched efficiency and net work with their ratios, and its efficiency, net work and regenerator state at your pressure ratio.
- Compressor work
-
Unit kJ/kg
About this output
The work taken by the compressor (both stages), in kJ/kg.
- Design meets the limits
-
No unit declared
About this output
Yes when your design gives positive net work, at least the floor, and keeps the compressor exit at or below the limit.
- The ten numbered states of the cycle (blank where your configuration does not use a state)
-
No unit declared
About this output
The ten numbered states of the cycle: temperature, pressure and entropy (measured from state 1), blank where your configuration does not use a state.
- Net work
-
Unit kJ/kg
About this output
The net work of your design, turbine work less compressor work, in kJ per kg of air.
- Compressor exit temperature
-
Unit K
About this output
T2, the compressor exit temperature in K (the last stage with two stages), compared with the exit limit.
- Challenge: the value scored
-
No unit declared
About this output
The value the challenge scores: the prediction code (challenge 1), the net work (2), the efficiency (3), T4 - T2 in K (4) or the share of Carnot (5).
- Challenge goal
-
No unit declared
About this output
The goal of the selected challenge.
- Challenge feedback
-
No unit declared
About this output
Feedback on the selected challenge: the prompt to predict, the met text, or a hint.
- Compressor efficiency used
-
No unit declared
About this output
The compressor efficiency the calculation used.
- Challenge result
-
No unit declared
About this output
No challenge selected, MET or NOT MET.
- Challenge score
-
No unit declared
About this output
100 when the selected challenge is met, else 0.
LogicCommons is in beta. If a result, label, or reference looks wrong, tell us here; we read every message.
Methodology
Purpose and model boundary
This lab designs a gas turbine on the air-standard Brayton cycle, with the cold-air standard (constant specific heats), in four configurations: simple (compressor, combustor, turbine); regenerated (the hot exhaust preheats the compressed air); intercooled and reheated (two compressor stages with cooling between them and two turbine stages with reheating between them); and all three together. For your design the model returns the ten numbered states, the compressor and turbine work, the heat added and rejected, the net work, the thermal efficiency against the Carnot limit and the cycle's path on the temperature-entropy (T-s) diagram. It also searches every configuration over 78 pressure ratios from 1.5 to 40, under a limit on the compressor exit temperature and a floor on the net work, refines the best ratio, names the simplest best configuration, and gives two closed-form results: the pressure ratio of the largest net work and the ratio where a regenerator stops helping. Five scored challenges go with it.
It is a lab for learning how the pressure ratio, the two temperatures, the component efficiencies and the cycle features shape a gas turbine: why work and efficiency peak at different ratios, why a regenerator helps at low ratios and stops helping at high ones, and how intercooling, reheat and regeneration bring a cycle closer to the Carnot limit. It is not a performance model of a real engine: there are no pressure losses, no fuel mass, no variable specific heats and no blade cooling, so real engines show lower figures.
The model is the calculation authority. The page sends the values you set to the model and draws only what it returns: the flow sheet with its numbered states, the cycle on the T-s diagram and its player, the efficiency and net-work curves of the search and the refinement all come from the model's own tables. The page computes no temperature, work, efficiency or search result itself.
Inputs and units
| Input | Meaning and unit |
|---|---|
| Cycle configuration | Simple (default), Regenerated, Intercooled and reheated, or Regenerated with intercooling and reheat. |
| Pressure ratio | r, the overall compressor pressure ratio p_high/p1, from 1.5 to 40 (default 10). Two-stage machines split it equally, √r per stage. |
| Ambient temperature | T1, the compressor inlet temperature, from 250 to 320 K (default 300 K). Intercooling cools back to it. |
| Turbine inlet temperature | T3, from 800 to 1,800 K (default 1,200 K): the hottest the turbine blades take. Reheating heats back to it. |
| Compressor efficiency | η_c, the isentropic efficiency of each compressor stage, from 0.70 to 1.00 (default 1, an ideal compressor). |
| Turbine efficiency | η_t, the isentropic efficiency of each turbine stage, from 0.70 to 1.00 (default 1, an ideal turbine). |
| Regenerator effectiveness | ε, the temperature effectiveness of the regenerator, from 0 to 1 (default 0.8). Used only by the two regenerated configurations, and only while the exhaust is hotter than the compressed air; checked always. |
| Search objective | Efficiency (default) or Net work: what the search maximises over the pressure ratios. |
| Highest compressor exit temperature | T2max, from 400 to 1,000 K (default 1,000 K): searched designs whose compressor stage exit is hotter are rejected. |
| Lowest net work | w_min, from 0 to 600 kJ/kg (default 0): the lowest acceptable net work of a searched design. |
| Challenge number | 0 for free exploration, or 1 to 5 to load a challenge. |
| Your prediction (challenge 1) | Not yet predicted (the start), Raises it, Lowers it or No change. |
Where each input is set:
- On the canvas only: the cycle configuration, chosen with the chip on the flow sheet, and your prediction in challenge 1, whose buttons appear only in that challenge. Neither is in the input panel.
- In the input panel: the pressure ratio, the two temperatures, the two component efficiencies, the regenerator effectiveness (shown only for the two regenerated configurations), the search objective, the two limits and the challenge number.
Governing relationships
The cold-air standard. Air is an ideal gas with constant c_p = 1.005 kJ/(kg K) and k = 1.4, so a = (k - 1)/k and the gas constant R = c_p·a. Heat and work are per kilogram of air.
One stage. With τ = r^a, the compressor exit is T2 = T1·(1 + (τ - 1)/η_c) and the turbine exit is T4 = T3·(1 - η_t·(1 - 1/τ)). The compressor work is c_p·(T2 - T1), the turbine work c_p·(T3 - T4), and the net work their difference. In these formulas T2 and T4 name the compressor exit and the turbine exit temperatures (states 4 and 9 in the state numbering below). Two equal stages use τ_h = r^(a/2) in each stage, intercool to T1 and reheat to T3, so the works double: w_c = 2·c_p·(T2h - T1) and w_t = 2·c_p·(T3 - T4h). The equal split is the work-optimal split for equal inlet temperatures.
The regenerator. It works only while the turbine exhaust is hotter than the compressor exit (T4 > T2); it then heats the compressed air to Tx = T2 + ε·(T4 - T2), and the exhaust leaves it at T4 - (Tx - T2). Otherwise it is bypassed and Tx = T2. Its benefit falls smoothly to zero at the switch. It never changes the work, only the heat that must be added.
Heat and efficiency. The heat added is c_p·(T3 - Tx) in the combustor, plus c_p·(T3 - T4h) in the reheater with two stages; the heat rejected is the exhaust down to T1, plus the intercooler with two stages. The thermal efficiency is the net work over the heat added, computed only while the combustor can add heat (Tx below T3). The back-work ratio is compressor work over turbine work. The Carnot efficiency, 1 - T1/T3, is the most any cycle between the two temperatures can reach, and the share of Carnot is the thermal efficiency over it. For the ideal simple cycle the efficiency is 1 - 1/r^a, whatever T3.
States and entropy. The ten numbered states follow the full cycle: 1 compressor inlet; 2 first stage exit; 3 intercooler exit; 4 compressor exit; 5 regenerator exit (combustor inlet); 6 turbine inlet; 7 first turbine stage exit; 8 reheater exit; 9 turbine exit; 10 regenerator exhaust exit. A simpler configuration uses a subset, so a number always means the same place. Each state's pressure is 100 kPa times its pressure ratio (1, √r or r), and its entropy, measured from state 1, is s = c_p·ln(T/T1) - R·ln(p/p1).
The T-s path. Each process is drawn with 10 points: constant-pressure heating and cooling follow the exact curve on which s is linear in ln T; compression and expansion are straight lines between their end states. With ideal components every process is reversible and the area inside the loop is the net work.
Closed-form checks (no limits). With n stages (1 or 2) and the stage temperature ratio t, the net work n·c_p·(η_t·T3·(1 - 1/t) - T1·(t - 1)/η_c) is largest at t* = √(η_c·η_t·T3/T1), where it is n·(c_p·T1/η_c)·(t* - 1)²; the overall ratio is t*^(n/a). For the ideal one-stage cycle the largest net work is c_p·(√T3 - √T1)². The regenerator stops helping where T4 = T2, the positive root t_x of (T1/η_c)·t² + (T1 - T1/η_c - T3·(1 - η_t))·t - η_t·T3 = 0; for ideal components it equals the work-maximising ratio. Both may lie outside 1.5 to 40.
The search. The model evaluates every configuration at the 78 ratios 1.5, 2, 2.5, ... 40. A ratio meets the limits when the net work is positive, at least the floor, and every compressor stage exit is at or below T2max. For each configuration and objective the best ratio is the highest value among those that meet the limits; values within one part in a billion of the best count as tied, and the lowest tied ratio is reported. The best configuration is the simplest one tied for the best value (under Net work a regenerator adds nothing, so pairs always tie). The best ratio of your configuration is then refined over 41 ratios in steps of 0.025 around it, inside 1.5 to 40, by the same rule.
Calculation sequence
- The model checks your values in the order of the status list under Errors and warnings, up to the challenge number and your prediction.
- It fixes the values in use: yours, or in a challenge the challenge's, except the inputs that challenge leaves free.
- It evaluates your design: the stage temperatures, works, regenerator, heats, efficiency, back-work ratio, the Carnot limit and its share, the ten states and whether the design meets the limits.
- It builds the 101-point T-s path of your configuration.
- It evaluates every configuration at the 78 searched ratios and finds each one's best ratio for both objectives, the best configuration and the margin over the runner-up.
- It refines your configuration's best ratio in 41 steps of 0.025.
- It computes the closed-form work-maximising ratio and work and the regenerator switch ratio for your staging.
- It sets the status and, in a challenge, scores the challenge and withholds what the challenge keeps back.
Outputs and interpretation
- Your design: the thermal efficiency, the net work (kJ/kg), the share of the Carnot efficiency and the Carnot efficiency; the heat added and heat rejected, the compressor work and turbine work (kJ/kg), the back-work ratio, the compressor exit temperature (K), whether the regenerator is bypassed, whether the design meets the limits, whether the components are ideal, and a design note: the combustor cannot add heat, the design cannot run (no positive net work), it breaks a limit, its regenerator is bypassed, or it runs and meets the limits. A design that cannot run is reported, not refused: its efficiency is shown, negative.
- The ten states: temperature (K), pressure (kPa) and entropy (kJ/(kg K)), each marked in use or not.
- The T-s path: entropy, temperature, the state each process starts from and the process kind, row by row.
- The search: for your configuration, the searched ratios meeting the limits (of 78), the best efficiency and the most net work with their ratios, whether the best lies at the edge of the range (1.5 or 40, where the true optimum may lie beyond), the margin over the runner-up, and the refined best ratio and value; over all configurations, the best configuration, the configurations tied for best, and the best value with its ratio. The search table gives every configuration's efficiency and net work at each searched ratio (blank where a ratio breaks a limit) with the Carnot limit; the configuration table gives each configuration's best designs and its values at your ratio.
- Closed-form checks: the work-maximising pressure ratio and the largest net work without limits, and the pressure ratio where the regenerator stops helping.
- Settings used and the model and module versions.
Reading the canvas: the flow sheet shows the chosen configuration and its numbered states, with a bypassed regenerator drawn dashed. The T-s diagram draws the cycle, process by process, and the player moves along it one row at a time. The search charts plot efficiency and net work against pressure ratio for every configuration, with your ratio marked.
What to take from the lab: net work peaks at a moderate pressure ratio, where the extra turbine work just pays for the extra compressor work, while the efficiency of the simple cycle keeps rising beyond it. A regenerator recovers exhaust heat only while the exhaust is hotter than the compressed air, so it helps most at low ratios. Intercooling, reheat and regeneration together, with a hot turbine, take in and reject heat closer to the two extreme temperatures and bring a real cycle much closer to the Carnot limit.
Challenges
Each challenge fixes T1 at 300 K and its other settings, and leaves the inputs it names to you. The model scores each one MET (100) or NOT MET (0) and gives a one-line hint while it is not met.
- Predict the trend (introductory). With an ideal regenerator (ideal components, ε = 1, T3 1,200 K), predict what raising the pressure ratio from 4 to 8 does to the efficiency. It is met when your prediction matches the trend the model computes between those two searched ratios.
- Most work (intermediate). With real components (η_c 0.85, η_t 0.90), set the pressure ratio of the simple cycle so the net work is at least 99% of the most the search finds. The value scored is your net work.
- Efficient and powerful (advanced). With a net-work floor of 250 kJ/kg and real components, choose the configuration and pressure ratio with the best efficiency: it is met when your design meets the limits and its efficiency is within 0.5 percentage points of the best design the search finds. The value scored is your efficiency.
- Find the switch (intermediate). Regenerated, with real components: set the pressure ratio where the regenerator stops helping, with the turbine exhaust (state 9) within 5 K of the compressor exit (state 4). The value scored is T4 - T2, the turbine exit temperature less the compressor exit temperature, in K.
- Close the Carnot gap (advanced). With real components and a regenerator effectiveness of 0.8, choose the configuration, pressure ratio and turbine inlet temperature to reach at least 66% of the Carnot efficiency with positive net work. The value scored is your share of Carnot.
Held-back results. While challenge 1 awaits your prediction, every result is blank except the status, the Carnot efficiency, the settings used and the challenge outputs; the search table keeps only its ratios and the Carnot line. Once you predict, right or wrong, everything shows. While challenges 2 to 5 are not met, the results that would give the answer away are blank: in challenge 2 the net-work curves, the refinement, the best-design results and the closed-form work maximum; in challenges 3 and 5 every search result and the configuration table's values at your ratio; in challenge 4 the regenerator switch ratio and the simple and regenerated efficiency curves. Your own design's results stay visible to work with, and a met challenge shows everything.
Validation and status logic
The status reads the first match in the list under Errors and warnings. The NOT VALID checks read the values you entered, whether or not the selected configuration, level or challenge uses them; the CHECK items read the values in use and apply inside challenges too. A challenge number that is not a whole number from 0 to 5 counts as no challenge selected. A design that cannot run, a design outside the limits, a bypassed regenerator and a best design at the edge of the range are results, reported by the design note and the yes or no outputs, not warnings.
Assumptions and limitations
- Air-standard Brayton cycle with constant c_p = 1.005 kJ/(kg K) and k = 1.4; no pressure losses, no fuel mass, no variable specific heats, no blade cooling. Real engines show lower figures.
- Two-stage machines use the equal pressure split and intercool exactly to T1 and reheat exactly to T3.
- The regenerator effectiveness is a temperature effectiveness on equal capacity rates, up to 1 (an ideal regenerator).
- The search is a grid: 78 ratios in steps of 0.5, then 41 in steps of 0.025 around the best. An optimum between grid points is approached, not found exactly; the closed forms show how close. The refinement is local; the coarse grid is the global search. An optimum beyond 40 is reported at the edge.
- The T-s path draws compression and expansion as straight lines between their end states; only with ideal components is the enclosed area the net work.
- Values within one part in a billion count as tied, and a design within one part in a billion of a limit or of the regenerator switch is flagged, because its side is decided by rounding.
Restrictions and non-computing states
Under NOT VALID every result and every table is blank, except the model and module versions; the challenge status (No challenge selected, or NOT MET when a challenge is selected), a score of 0, and the goal and not-met hint of a selected challenge.
When the compressor exit is at least as hot as the turbine inlet, the combustor cannot add heat: the thermal efficiency, the heat added and the share of Carnot are blank, and the design note says why. When no searched ratio meets the limits for your configuration, its search results are blank.
In challenges 1 to 5 the results listed under Challenges stay blank until the challenge allows them.
Errors and warnings
The status messages, first match wins:
- NOT VALID: choose the cycle configuration from the list
- NOT VALID: the pressure ratio must be a number from 1.5 to 40
- NOT VALID: the ambient temperature must be a number from 250 to 320 K
- NOT VALID: the turbine inlet temperature must be a number from 800 to 1800 K
- NOT VALID: the compressor and turbine efficiencies must be numbers from 0.7 to 1
- NOT VALID: the regenerator effectiveness must be a number from 0 to 1
- NOT VALID: choose the search objective from the list
- NOT VALID: the compressor exit limit must be a number from 400 to 1000 K
- NOT VALID: the net-work floor must be a number from 0 to 600 kJ/kg
- NOT VALID: the challenge number must be a whole number from 0 to 5, and the prediction one of the listed choices
- CHECK: a design lies within one part in a billion of a limit or of the regenerator switch, so its side is decided by rounding: a searched or refined design, or yours, sits on the net-work floor, the exit limit, the regenerator switch or the point where the combustor can no longer add heat.
- CHECK: no pressure ratio from 1.5 to 40 meets the limits for this configuration; raise the compressor exit limit or lower the net-work floor
- CHECK: two searched pressure ratios give the same best value to one part in a billion; the lower ratio is reported
- OK
A blank list choice is refused by the page before the model runs.
References
This laboratory is an educational model of the gas-turbine (Brayton) cycle on the cold-air standard, with constant specific heats. It applies isentropic relations with compressor and turbine efficiencies, a regenerator of given temperature effectiveness, and two-stage compression and expansion with intercooling and reheat, and compares the thermal efficiency with the Carnot limit. An exhaustive search over pressure ratios is shown beside the closed-form pressure ratio of the largest net work and the ratio at which the turbine exhaust is no hotter than the compressed air.
Sources and further reading
- The ideal Brayton cycle, its efficiency in terms of the pressure ratio, and the condition and value of the largest net work: Massachusetts Institute of Technology, Thermodynamics and Propulsion course notes, section 3.7, Brayton Cycle. MIT
- The Brayton cycle on temperature-entropy coordinates, with its isentropic and constant-pressure legs: Massachusetts Institute of Technology, Thermodynamics and Propulsion course notes, section 6.4, Brayton Cycle in T-s Coordinates. MIT
- The gas turbine's processes, its p-V and T-s diagrams, and why real compression is not isentropic: NASA Glenn Research Center, Turbine Engine Thermodynamic Cycle: Brayton Cycle, an educational page on propulsion. NASA Glenn Research Center
- The Brayton cycle with intercooling, reheating and regeneration, isentropic efficiencies, the back-work ratio and the Carnot efficiency: Y. A. Çengel and M. A. Boles, Thermodynamics: An Engineering Approach, 9th edition, McGraw-Hill, 2019, chapter 6, The Second Law of Thermodynamics, and chapter 9, Gas Power Cycles.
No table or text from any of these publications is reproduced, and none of their authors or publishers has reviewed or endorses this laboratory.
This laboratory is for learning. Its results hold only within its stated ranges; a real gas turbine, with pressure losses, fuel mass, varying specific heats and cooled blades, reaches lower efficiency and work than this ideal model.
Links were current at build time. If one moves, search the document's title rather than reporting a broken link as a defect.
Found a problem, or have an idea?
Tell us if a result looks wrong, a label is unclear, or something is missing. We read every message.