Soil mechanics

Direct Shear Test Interpretation

Fits the linear Mohr-Coulomb failure envelope, shear stress = cohesion + normal stress x tan(friction angle), by least squares to drained direct shear test results, separately for peak and residual strength, for each sample and for each stratum group of samples, with or without a cohesion intercept. It gives the cohesion, the friction angle, R-squared, the slope standard error and each specimen's residual, refuses a sample with fewer than three specimens at different normal stresses, and flags poor fits, a cohesion below zero, an undrained label and an implausible friction angle. Every figure comes from the model.

Last updated

Calculator overview

Inputs and outputs

This summary comes from the calculator's published input and output contract.

Inputs

Samples (required)
About this input

One row per soil sample: its id (1 to 32 characters, used to join the other tables), and optionally the borehole it came from and its top and bottom depth in metres (0 to 500, bottom not above top).

Default 4 rows
ColumnRange or allowed values
Sample ID Not declared
Borehole ID Not declared
Top depth (m) 0 to 500
Bottom depth (m) 0 to 500
Specimens (required)
About this input

One row per sheared specimen: its sample id, the normal stress (1 to 5,000 kPa), the peak shear stress (0 to 5,000 kPa) and, if measured, the residual shear stress (0 to 5,000 kPa, not above the peak).

Default 12 rows
ColumnRange or allowed values
Sample ID Not declared
Normal stress (kPa) 1 to 5000
Peak shear stress (kPa) 0 to 5000
Residual shear stress (kPa) 0 to 5000
Stress unit shown (required)
About this input

The unit the cohesion, the stresses and the residuals are shown in: kPa or psf (1 psf = 0.0478802589803 kPa). The tables always take kPa.

Default kPa Allowed kPa, psf
Sample Group (required)
About this input

One row per sample: its id, an optional stratum name (samples with the same name also get a combined envelope through all their specimens) and its drainage label, Drained (slow shear) or Not confirmed drained.

Default 4 rows
ColumnRange or allowed values
Sample ID Not declared
Stratum Not declared
Drainage Drained (slow shear), Not confirmed drained
Envelope shown on the chart (required)
About this input

The envelope the chart shows: First fitted (the default), Sample k (the k-th sample of the fit tables) or Stratum k (the k-th stratum).

Default Stratum 1 Allowed First fitted, Sample 1, Sample 2, Sample 3, Sample 4, Sample 5, Sample 6, Sample 7, Sample 8, Sample 9, Sample 10, Sample 11, Sample 12, Sample 13, Sample 14, Sample 15, Sample 16, Sample 17, Sample 18, Sample 19, Sample 20, Stratum 1, Stratum 2, Stratum 3, Stratum 4, Stratum 5, Stratum 6, Stratum 7, Stratum 8, Stratum 9, Stratum 10, Stratum 11, Stratum 12, Stratum 13, Stratum 14, Stratum 15, Stratum 16, Stratum 17, Stratum 18, Stratum 19, Stratum 20
Envelope fit (required)
About this input

How the envelope is fitted: Fit cohesion fits both the cohesion intercept and the slope; Cohesion zero forces the line through the origin, which suits clean sands, whose fitted cohesion is usually an artefact of the test.

Default Fit cohesion Allowed Fit cohesion, Cohesion zero
Lowest acceptable R-squared (required)
About this input

The lowest R-squared a fitted envelope may have before the status asks you to look at the specimen residuals, from 0 to 1. The default 0.95 is a screening value you can change, not a value from a standard.

Default 0.95 Range 0 to 1

Outputs

Peak R-squared of the envelope shown
About this output

R-squared of the peak envelope shown (uncentred with Cohesion zero). When the envelope is fitted with cohesion and every shear stress is equal, the centred R-squared is 0/0; it is reported as 1 and the status OK by convention, because the flat line fits exactly. With Cohesion zero the uncentred R-squared is computed as usual (1 only when every shear stress is zero).

No unit declared
Residual cohesion of the envelope shown
About this output

The residual cohesion intercept of the envelope shown, in the stress unit shown; blank without three residual readings at different normal stresses.

Unit kPa
Peak cohesion of the envelope shown
About this output

The peak cohesion intercept of the envelope shown, in the stress unit shown; 0 with Cohesion zero; blank when it could not be fitted.

Unit kPa
Peak friction angle of the envelope shown (degrees)
About this output

The peak friction angle of the envelope shown, in degrees (the angle whose tangent is the fitted slope).

No unit declared
Residual friction angle of the envelope shown (degrees)
About this output

The residual friction angle of the envelope shown, in degrees.

No unit declared
Status code
About this output

The status as a short code for the page (OK, CHECK or INPUT_INVALID); not shown to the reader.

No unit declared
Summary
About this output

One line: the samples and specimens read, how many envelopes were fitted and the range of the peak friction angles.

No unit declared
Residual R-squared of the envelope shown
About this output

R-squared of the residual envelope shown.

No unit declared
Specimen Residuals
About this output

For each specimen: its sample, its normal stress, and how far its peak and residual shear stresses lie above (positive) or below (negative) its sample's fitted envelope, in the unit shown.

No unit declared
Envelope shown on the chart
About this output

The sample or stratum whose envelope the chart and the envelope points show.

No unit declared
Model status
About this output

OK, CHECK: with a sentence to read before using the results, or NOT VALID: with the first problem to fix, in which case no result is shown.

No unit declared
Peak Fit
About this output

The peak strength envelope of each sample, then of each stratum: the cohesion (in the unit shown), the friction angle in degrees and R-squared. Blank where the sample could not be fitted.

No unit declared
Envelope Points
About this output

The points the chart draws for the envelope shown: each specimen's normal stress, its measured shear stress and the fitted shear stress at that normal stress, first for the peak, then for the residual strength.

No unit declared
Fit Detail
About this output

For each fit: the number of specimens, the standard error of the peak envelope slope, and the row status in plain words (fitted, or why not).

No unit declared
Largest fitted peak friction angle (degrees)
About this output

The largest peak friction angle of all fitted samples and strata, in degrees.

No unit declared
Row Status
About this output

Every input row in use, Samples, then Sample groups, then Specimens: Used, or Excluded with the reason. An excluded row is left out of every fit; the other rows are still computed.

No unit declared
Samples fitted
About this output

How many samples have a fitted peak envelope (three or more specimens at two or more different normal stresses).

No unit declared
Smallest fitted peak friction angle (degrees)
About this output

The smallest peak friction angle of all fitted samples and strata, in degrees.

No unit declared
Residual Fit
About this output

The residual strength envelope of each sample, then of each stratum, from the specimens with a residual reading: the cohesion, the friction angle in degrees and R-squared. Blank where there are too few residual readings.

No unit declared
This page is provided by LogicCommons for informational purposes only. Results are analysis outputs computed from the inputs you supply and are not engineering advice, a design, or a substitute for review by a licensed professional under the codes adopted where the work is built. Verify all inputs and results independently.

LogicCommons is in beta. If a result, label, or reference looks wrong, tell us here; we read every message.

Methodology

Purpose and model boundary

This calculator interprets a series of direct shear tests: for each sample, and for each group of samples you name as one stratum, it fits a straight Mohr-Coulomb failure line through the specimens' shear stresses at failure and reports the cohesion intercept, the friction angle and the quality of the fit, separately for peak and for residual strength. It also reports each specimen's distance from its line, so an odd specimen stands out.

It is an interpretation aid for education and preliminary work. The parameters describe the specimens as tested; choosing design strength for a footing, a wall or a slope needs the test conditions, the soil's variability and professional judgement. Only straight failure lines are fitted.

Inputs and units

  • Samples: a sample name, the boring it came from and its top and bottom depth in metres.
  • Sample details (every sample): an optional stratum name, so that samples sharing it are also fitted together, and whether the test is confirmed as drained (sheared slowly enough for no excess pore pressure).
  • Specimens: one row per specimen, with its sample, the normal stress it was sheared under and its peak shear stress, all in kilopascals, and optionally its residual shear stress after large displacement.
  • Fit settings: whether the line fits a cohesion intercept or passes through the origin (cohesion zero), the least acceptable fit quality, the stress unit for the results (kPa or psf; 1 psf is 0.0478802589803 kPa), and which sample or stratum the chart shows (the first fitted one unless you choose another).

Governing relationships

The failure line is

τ = c + σ tan φ

with σ the normal stress, τ the shear stress at failure, c the cohesion intercept and φ the friction angle. For n specimens, the least-squares line with an intercept has

b = (n Σστ − Σσ Στ) / (n Σσ² − (Σσ)²) and c = (Στ − b Σσ) / n

and the line through the origin has b = Σστ / Σσ² and c = 0. In both cases φ = arctan b. The fit quality is R² = 1 − SSres / SStot for the line with an intercept, and the uncentred form for the line through the origin, stated as such. For the line with an intercept, when every shear stress in a fit is the same, SStot is zero and the formula is 0/0; the line fits those points exactly, so the workbook reports R² = 1 and the fit passes the minimum-R² check. Each specimen's residual is τ − (c + b σ).

Calculation sequence

  1. Check the settings and that every sample is entered once. Check each table row; a bad row, or a row naming a sample that is not entered, is excluded with its reason and the other rows are still used.
  2. Group the specimens by sample, and by stratum name where one is given.
  3. For each sample and each stratum with at least three specimens at two or more different normal stresses, fit the peak line, and the residual line where residual stresses are entered.
  4. Compute the friction angle, the fit quality, the standard error of the slope and each specimen's residual.
  5. Flag a negative fitted cohesion, a fit below the least acceptable quality, an unconfirmed drainage condition and a friction angle outside 0 to 60 degrees.
  6. Convert the reported stresses to the chosen unit.

Outputs and interpretation

The summary gives the number of samples fitted. The peak and residual tables give each sample's and each stratum's cohesion, friction angle and fit quality. The fit detail gives the number of specimens used, the standard error of the slope and the row status. The input row status table says whether each entered row was used or excluded, and why. The residual table gives every specimen's distance from its line; a large one marks a specimen worth checking. The chart shows the measured points and the fitted lines of the sample or stratum chosen under Fit settings, and the values of that line are listed beside it.

Worked examples

The lab values in the examples are illustrative data for the shared synthetic sample sites; they are not from a real property.

  1. Business-park silty sand for footings. Four samples, peak and residual, combined as one stratum.
  2. Retaining-wall backfill from three suppliers. Three sources at wall-level stresses; compare with cohesion zero.
  3. Highway cut clay residual strength. Two clay samples at four normal stresses, peak and residual.
  4. Warehouse pad compacted fill check. Three fill samples combined, against the fit-quality threshold.
  5. Basement sand series with a bad specimen and a short set. One odd specimen, one sample with two specimens.

Validation and status logic

The status reads OK, CHECK: (results with a caution) or NOT VALID: (no results). The first rule that applies wins:

Condition Returned status
A setting is not in its list or range NOT VALID: naming the setting
No sample or no specimen is entered NOT VALID: saying so
A sample is repeated in the Samples table or in the sample details NOT VALID: naming the row and the sample
A row holds a value outside its allowed range, a residual shear stress above the peak, a missing drainage label, or names a sample that is not entered CHECK: giving how many input rows were excluded; the row status table says why
A sample has fewer than three specimens, or only one normal stress CHECK: giving how many samples could not be fitted; each row says why
A fit with a cohesion intercept gives a cohesion below zero CHECK: naming the sample and suggesting the cohesion-zero line
A fit is below the least acceptable quality CHECK: naming the sample and its fit quality
A sample is not confirmed as drained CHECK: naming the sample
A friction angle is outside 0 to 60 degrees CHECK: naming the sample
The chart choice names no sample or stratum in the fit tables CHECK: saying so; the chart shows the first fitted line
None of the above OK

Assumptions and limitations

  • The specimens were consolidated and sheared drained, so the stresses are effective stresses.
  • The failure line is straight over the stresses tested; strength at stresses outside that range is not implied.
  • The shear plane is forced by the box, so a direct shear result may differ from other strength tests.
  • A cohesion fitted to a clean sand is usually an artefact of the line, not a true bond.
  • The least acceptable fit quality is the reader's choice, not a value from a standard.

Restrictions and non-computing states

The page opens with empty tables; choose a worked example or enter your own rows, then press Calculate. The input rules refuse a value outside its allowed range before calculation. In the calculation, a bad row is excluded and named in the row status table while the other rows are still fitted, and a sample without enough specimens at different normal stresses is reported without a line rather than fitted.

Errors and warnings

A rejected entry means the request did not satisfy the published input rules. NOT VALID means the series cannot be interpreted as entered, and names the first problem. CHECK means the fitted lines are reported but one or more need attention: read each row's status. A calculation-service failure is an availability error, not a test result.

References

Sources and further reading

  • ASTM International, Standard Test Method for Direct Shear Test of Soils Under Consolidated Drained Conditions, ASTM D3080/D3080M-23. astm.org. The test method whose results are interpreted here, which calls for three or more specimens at different normal stresses. It is sold by ASTM; this page reproduces none of its tables or wording.
  • Federal Highway Administration, Soils and Foundations Reference Manual, Volume I, FHWA NHI-06-088 (December 2006), section 5.5.2.3. fhwa.dot.gov. A public description of the direct shear test and of the Mohr-Coulomb failure line it is used to define.

The applicable test standards, project requirements and review by a qualified geotechnical professional govern the selection of design strength parameters.

Results are informational and not professional advice. See our Terms of Use. Powered by SpreadsheetWeb · About · Privacy · Terms