Calculator overview
Inputs and outputs
This summary comes from the calculator's published input and output contract.
Inputs
- Specimen Failure (required)
-
Default 9 rows
About this input
One row per specimen, matched by its id: the deviator stress at failure in kPa and, for a CU test, the excess pore pressure at failure in kPa (blank for UU and CD tests).
Column Range or allowed values SpecimenID Not declared Deviator_kPa 0.1 to 50000 ExcessPore_kPa -5000 to 20000 - Sample Test (required)
-
Default 3 rows
About this input
One row per sample with its test type, UU, CU or CD, and an optional stratum name. Samples with the same stratum name are also fitted together as one stratum.
Column Range or allowed values SampleID Not declared Type Unconsolidated undrained (UU), Consolidated undrained with pore pressure (CU), Consolidated drained (CD) Stratum Not declared - Stress unit shown in the results (required)
-
Default kPa Allowed kPa, psf
About this input
The unit of every stress in the results and on the charts: kPa or psf. The stresses are always entered in kPa.
- Specimen Stress (required)
-
Default 9 rows
About this input
One row per specimen: its id, its sample, the cell pressure and the back pressure in kPa. The net confining stress is the cell pressure minus the back pressure; a blank back pressure is 0.
Column Range or allowed values SpecimenID Not declared SampleID Not declared Cell_kPa 0 to 20000 Back_kPa 0 to 20000 - Samples (required)
-
Default 3 rows
About this input
One row per sample: its id, the borehole it came from and its top and bottom depth in metres. The borehole and depths are optional; an unused row is left blank.
Column Range or allowed values SampleID Not declared BoreholeID Not declared TopDepth_m 0 to 500 BottomDepth_m 0 to 500 - Failure point used for the deviator stress (required)
-
Default Maximum deviator stress Allowed Maximum deviator stress, Maximum principal stress ratio
About this input
The failure point at which you read the deviator stress of each specimen: the maximum deviator stress or the maximum principal stress ratio. It is recorded with the results; the calculator does not pick the point from a stress-strain record.
- Sample shown on the charts (required)
-
Default Sample 1 Allowed Sample 1, Sample 2, Sample 3, Sample 4, Sample 5, Sample 6, Sample 7, Sample 8, Sample 9, Sample 10, Sample 11, Sample 12, Sample 13, Sample 14, Sample 15, Sample 16, Sample 17, Sample 18, Sample 19, Sample 20
About this input
Which sample the charts draw: Sample 1 is the first sample in the samples table, Sample 2 the second, and so on. A number beyond the samples entered draws the first sample with a usable specimen and gives a CHECK.
- Smallest acceptable R-squared (required)
-
Default 0.95 Range 0 to 1
About this input
The smallest R-squared you accept for a fitted envelope, from 0 to 1. A fit below it gives a CHECK so you look at its specimens; it is your own threshold, not a value from a standard.
- Envelope fit (required)
-
Default Fit cohesion Allowed Fit cohesion, Cohesion zero
About this input
How the strength envelope is fitted: Fit cohesion fits both the cohesion and the friction angle; Cohesion zero forces the line through the origin, which suits clean sands and gravels whose fitted cohesion is usually an artefact of the data.
Outputs
- Specimen Effective
-
No unit declared
About this output
For every used CU and CD specimen: the effective confining stress, the effective major principal stress and the circle centre s', each the total value minus the excess pore pressure at failure (zero in a CD test).
- Specimen Status
-
No unit declared
About this output
Every specimen row entered, with its sample, test type and status: Used, or Excluded with the reason in plain words (a missing or out-of-range value, a missing failure reading, or an effective confining stress below zero). Excluded rows are left out of every result; the others are still computed.
- Specimen Total
-
No unit declared
About this output
For every specimen: the net confining stress sigma3, the major principal stress sigma1 at failure and the circle radius t, half the deviator stress, in the stress unit shown.
- R-squared of its total-stress fit
-
No unit declared
About this output
The R-squared of the total-stress fit of the sample shown.
- Undrained shear strength of the sample shown
-
Unit kPa
About this output
The undrained shear strength Su of the sample shown, when it is a UU sample with a usable specimen, in the stress unit shown.
- Test type of the sample shown
-
No unit declared
About this output
The test type of the sample shown on the charts: UU, CU or CD.
- Specimens used
-
No unit declared
About this output
The number of specimens whose readings entered a result. A specimen is left out when its failure reading or its pore pressure is missing, or when its effective confining stress comes out below zero.
- Effective-stress friction angle of that stratum
-
Unit deg
About this output
The effective-stress friction angle of that stratum, in degrees.
- R-squared of the stratum fit
-
No unit declared
About this output
The R-squared of the stratum's effective-stress fit.
- Summary
-
No unit declared
About this output
One line: samples interpreted by test type, specimens used, the failure point recorded and the stress unit shown.
- Status code
-
No unit declared
About this output
A one-word code for the status line: OK, CHECK, INPUT_INVALID or UNSUPPORTED (a test type this calculator does not interpret). It is for programs reading the result, not for display.
- Effective-stress cohesion of that stratum
-
Unit kPa
About this output
The effective-stress cohesion c' of that stratum, fitted over all usable specimens of its samples, in the stress unit shown.
- First stratum fitted in effective stress
-
No unit declared
About this output
The first stratum, in table order, with two or more CU or CD samples, which is fitted as a whole in effective stress.
- R-squared of its effective-stress fit
-
No unit declared
About this output
The R-squared of the effective-stress fit of the sample shown.
- Model status
-
No unit declared
About this output
OK when every row was used and every sample interpreted cleanly; CHECK with the first excluded row or the first result that needs a second look, while every valid row is still computed; NOT VALID only when nothing can be computed (no specimen, a repeated id or a setting outside its list), and then every result is blank.
- Sample Effective Fit
-
No unit declared
About this output
Effective-stress strength of each CU and CD sample, then of each stratum with two or more such samples: the cohesion in the stress unit shown, the friction angle in degrees and the R-squared of the fit. Blank where no line could be fitted.
- Sample Status
-
No unit declared
About this output
Every sample row entered, in table order (Sample 1, Sample 2, ...), with its test type, the number of usable specimens and its status: interpreted or fitted, or Excluded or not fitted with the reason in plain words.
- Sample shown on the charts
-
No unit declared
About this output
The sample whose Mohr circles and envelope the charts draw.
- Circle Points
-
No unit declared
About this output
The points the charts draw for the chart sample: 37 points along the upper half of each Mohr circle (at most four total-stress and four effective-stress circles) and the two end points of each fitted failure line.
- Effective-stress chart applies (1 yes, 0 no)
-
No unit declared
About this output
1 when the effective-stress chart has at least one circle to draw (the sample shown is a CU or CD sample with a used specimen), 0 otherwise (a UU sample, or an excluded one). For the page, which hides the effective-stress chart when it is 0; not shown as a result.
- Sample Total Fit
-
No unit declared
About this output
Total-stress strength of each CU sample, then of each stratum with two or more CU samples: the cohesion in the stress unit shown, the friction angle in degrees and the R-squared of the fit. Blank where no line could be fitted.
- Total-stress cohesion of the sample shown
-
Unit kPa
About this output
The total-stress cohesion c of the sample shown, when it is a CU sample with a fitted line, in the stress unit shown.
- Effective-stress friction angle of the sample shown
-
Unit deg
About this output
The effective-stress friction angle of the sample shown, in degrees, when it is a CU or CD sample with a fitted line.
- Total-stress friction angle of the sample shown
-
Unit deg
About this output
The total-stress friction angle of the sample shown, in degrees, when it is a CU sample with a fitted line.
- Sample Undrained
-
No unit declared
About this output
Undrained shear strength Su of each UU sample, the mean circle radius of its usable specimens, listed by top depth, with the number of specimens.
- Samples interpreted
-
No unit declared
About this output
The number of samples with a result: a UU sample with an undrained shear strength, or a CU or CD sample with a fitted effective-stress envelope.
- Effective-stress cohesion of the sample shown
-
Unit kPa
About this output
The effective-stress cohesion c' of the sample shown, when it is a CU or CD sample with a fitted line, in the stress unit shown.
LogicCommons is in beta. If a result, label, or reference looks wrong, tell us here; we read every message.
Methodology
Purpose and model boundary
This calculator interprets a series of triaxial compression tests. From each specimen's cell pressure, back pressure, deviator stress and, for consolidated undrained tests, excess pore pressure at failure, it finds the principal stresses and the Mohr circle at failure. It then fits a straight failure line to each sample's circles, and to each group of samples named as one stratum, giving the cohesion and friction angle in total and in effective stress. For unconsolidated undrained tests it reports the undrained shear strength instead.
It is an interpretation aid for education and preliminary work. Three test types are covered: unconsolidated undrained, consolidated undrained with pore pressure measured, and consolidated drained. Stress-path, anisotropically consolidated, cyclic and unsaturated tests are outside its scope. The failure point is read by the laboratory; the calculator does not pick it from a stress-strain curve.
Inputs and units
- Samples: a sample name, the boring it came from and its top and bottom depth in metres.
- Test type (every sample): the test type, and an optional stratum name so that samples sharing it are also fitted together.
- Specimens: one row per specimen with its name, its sample, the cell pressure and the back pressure (blank for none), in kilopascals.
- Failure readings: for each specimen, the deviator stress at failure and, for a consolidated undrained test, the excess pore pressure at failure, in kilopascals.
- Fit settings: whether the line fits a cohesion intercept or passes through the origin, the least acceptable fit quality, which failure point the readings record (maximum deviator stress or maximum principal stress ratio, a label kept with the results), the stress unit for the results, and the sample shown on the charts (Sample 1 is the first row of the samples table).
Governing relationships
Total principal stresses at failure, net of the back pressure:
σ3 = cell pressure − back pressure and σ1 = σ3 + deviator stress
Effective stresses for a consolidated undrained test, with u the excess pore pressure at failure:
σ3′ = σ3 − u and σ1′ = σ1 − u
For a consolidated drained test the effective stresses equal the total stresses. Each circle has its centre and radius at
s = (σ1 + σ3) / 2 and t = (σ1 − σ3) / 2
A least-squares line t = a + s tan α through the circles' tops (the same closed forms as a direct shear line) gives
φ = arcsin(tan α) and c = a / cos φ
For an unconsolidated undrained test, the undrained shear strength of a specimen is Su = t, and a sample's is the
mean of its specimens.
Calculation sequence
- Check the settings and that no sample or specimen is entered twice. Check each table row; a bad row, or a row naming a sample or specimen that is not entered, is excluded with its own status and every other row is still used.
- For each specimen compute the total stresses and, by test type, the effective stresses; exclude a consolidated undrained specimen without an excess pore pressure, and one whose effective confining stress is below zero.
- For an unconsolidated undrained sample, report the undrained shear strength.
- For each other sample, and each stratum, with at least two usable specimens at different confining stresses, fit the total-stress and the effective-stress lines; two specimens define a line exactly, so a third is needed to check it.
- Flag a negative fitted cohesion, a fit below the least acceptable quality and a friction angle outside 0 to 60 degrees.
- Draw the chosen sample's circles and fitted lines, in total and in effective stress, and convert the reported stresses to the chosen unit.
Outputs and interpretation
The summary gives the number of samples interpreted. The strength tables give each sample's and each stratum's cohesion, friction angle and fit quality, in effective and in total stress. The undrained table lists each unconsolidated undrained sample by depth with its undrained shear strength and specimen count. The specimen tables give the stresses at failure, and the status tables say whether each sample and specimen was used, and why not. The two charts show the chosen sample's Mohr circles and fitted lines in total and in effective stress, and its values are listed beside them. Effective stress applies to CU and CD tests only, so for a UU sample the effective-stress chart is replaced by a line saying so.
Worked examples
The lab values in the examples are illustrative data for the shared synthetic sample sites; they are not from a real property.
- Soft-clay CU tests with pore pressure. Three samples, three specimens each, under a back pressure.
- Stiff-clay UU strength profile. Six samples at 6, 9 and 12 m, one specimen each.
- Dense sand and gravel CD tests. Two samples at three confining stresses; compare with cohesion zero.
- Basement clay with back pressure. Four specimens under a high back pressure, combined as one stratum.
- Warehouse series with a data-entry error. Mixed test types, and one impossible pore pressure.
Validation and status logic
The status reads OK, CHECK: (results with a caution) or NOT VALID: (no results). The first rule that applies wins:
| Condition | Returned status |
|---|---|
| No specimen is entered | NOT VALID: enter at least one sample with its specimens |
| A sample or specimen is entered twice in the same table | NOT VALID: naming the row and the repeated name |
| A setting is not in its list or range | NOT VALID: naming the setting |
| A row has a bad value, names a sample or specimen that is not entered, or a specimen has no failure row; a consolidated undrained specimen has no excess pore pressure or an effective confining stress below zero | CHECK: naming the first excluded row and how many more; each row's status says why |
| A drained or unconsolidated undrained specimen has an excess pore pressure | CHECK: naming the specimen; the value is not used |
| A sample has too few usable specimens, or a line steeper than a strength envelope allows | CHECK: naming the sample; its row says why |
| A line rests on only two specimens, a cohesion below zero, a fit below the least acceptable quality, or a friction angle outside 0 to 60 degrees | CHECK: naming the sample or stratum |
| The chart sample is beyond the samples entered | CHECK: saying which sample the charts show instead |
| None of the above | OK |
Assumptions and limitations
- The specimens were saturated, and the readings are at the failure point the laboratory chose.
- The failure line is straight over the stresses tested.
- Total-stress parameters from consolidated undrained tests describe that test path only.
- Undrained strength depends on the specimen's depth, sampling disturbance and test rate.
- The least acceptable fit quality is the reader's choice, not a value from a standard.
Restrictions and non-computing states
The page opens with empty tables; choose a worked example or enter your own rows, then press Calculate. The input rules refuse a value outside its allowed range before calculation. In the calculation, a bad row is excluded with its own status while the other rows are still used, a specimen without a usable effective stress is left out of its sample's fit, and a sample without enough usable specimens is reported without a line. Tests other than UU, CU and CD are not interpreted.
Errors and warnings
A rejected entry means the request did not satisfy the published input rules. NOT VALID means the series cannot be interpreted as entered, and names the first problem. CHECK means the results are reported but some need attention: read each row's status. A calculation-service failure is an availability error, not a test result.
References
Sources and further reading
- ASTM International, Standard Test Method for Consolidated Undrained Triaxial Compression Test for Cohesive Soils, ASTM D4767-11 (reapproved 2020). store.astm.org. The test method for consolidated undrained tests with pore pressure measured.
- ASTM International, Standard Test Method for Consolidated Drained Triaxial Compression Test for Soils, ASTM D7181-20. store.astm.org. The test method for consolidated drained tests.
- ASTM International, Standard Test Method for Unconsolidated-Undrained Triaxial Compression Test on Cohesive Soils, ASTM D2850-26. store.astm.org. The test method for unconsolidated undrained tests.
- Federal Highway Administration, Soils and Foundations Reference Manual, Volume I, FHWA NHI-06-088 (December 2006), section 5.5.2.2. fhwa.dot.gov. A public description of triaxial testing and of total and effective stress strength.
The standards are sold by ASTM; this page reproduces none of their tables or wording. The applicable test standards, project requirements and review by a qualified geotechnical professional govern the selection of design strength parameters.
Found a problem, or have an idea?
Tell us if a result looks wrong, a label is unclear, or something is missing. We read every message.