Soil mechanics

Triaxial Test Interpretation

Interprets a laboratory series of triaxial compression tests (UU, CU with pore pressure, CD): the total and effective stresses at failure of every specimen, the Mohr circles, the undrained shear strength of UU samples listed by depth, and the cohesion and friction angle of CU and CD samples and strata from a least-squares envelope, with each specimen that could not be used named in plain words.

Last updated

Calculator overview

Inputs and outputs

This summary comes from the calculator's published input and output contract.

Inputs

Specimen Failure (required)
About this input

One row per specimen, matched by its id: the deviator stress at failure in kPa and, for a CU test, the excess pore pressure at failure in kPa (blank for UU and CD tests).

Default 9 rows
ColumnRange or allowed values
SpecimenID Not declared
Deviator_kPa 0.1 to 50000
ExcessPore_kPa -5000 to 20000
Sample Test (required)
About this input

One row per sample with its test type, UU, CU or CD, and an optional stratum name. Samples with the same stratum name are also fitted together as one stratum.

Default 3 rows
ColumnRange or allowed values
SampleID Not declared
Type Unconsolidated undrained (UU), Consolidated undrained with pore pressure (CU), Consolidated drained (CD)
Stratum Not declared
Stress unit shown in the results (required)
About this input

The unit of every stress in the results and on the charts: kPa or psf. The stresses are always entered in kPa.

Default kPa Allowed kPa, psf
Specimen Stress (required)
About this input

One row per specimen: its id, its sample, the cell pressure and the back pressure in kPa. The net confining stress is the cell pressure minus the back pressure; a blank back pressure is 0.

Default 9 rows
ColumnRange or allowed values
SpecimenID Not declared
SampleID Not declared
Cell_kPa 0 to 20000
Back_kPa 0 to 20000
Samples (required)
About this input

One row per sample: its id, the borehole it came from and its top and bottom depth in metres. The borehole and depths are optional; an unused row is left blank.

Default 3 rows
ColumnRange or allowed values
SampleID Not declared
BoreholeID Not declared
TopDepth_m 0 to 500
BottomDepth_m 0 to 500
Failure point used for the deviator stress (required)
About this input

The failure point at which you read the deviator stress of each specimen: the maximum deviator stress or the maximum principal stress ratio. It is recorded with the results; the calculator does not pick the point from a stress-strain record.

Default Maximum deviator stress Allowed Maximum deviator stress, Maximum principal stress ratio
Sample shown on the charts (required)
About this input

Which sample the charts draw: Sample 1 is the first sample in the samples table, Sample 2 the second, and so on. A number beyond the samples entered draws the first sample with a usable specimen and gives a CHECK.

Default Sample 1 Allowed Sample 1, Sample 2, Sample 3, Sample 4, Sample 5, Sample 6, Sample 7, Sample 8, Sample 9, Sample 10, Sample 11, Sample 12, Sample 13, Sample 14, Sample 15, Sample 16, Sample 17, Sample 18, Sample 19, Sample 20
Smallest acceptable R-squared (required)
About this input

The smallest R-squared you accept for a fitted envelope, from 0 to 1. A fit below it gives a CHECK so you look at its specimens; it is your own threshold, not a value from a standard.

Default 0.95 Range 0 to 1
Envelope fit (required)
About this input

How the strength envelope is fitted: Fit cohesion fits both the cohesion and the friction angle; Cohesion zero forces the line through the origin, which suits clean sands and gravels whose fitted cohesion is usually an artefact of the data.

Default Fit cohesion Allowed Fit cohesion, Cohesion zero

Outputs

Specimen Effective
About this output

For every used CU and CD specimen: the effective confining stress, the effective major principal stress and the circle centre s', each the total value minus the excess pore pressure at failure (zero in a CD test).

No unit declared
Specimen Status
About this output

Every specimen row entered, with its sample, test type and status: Used, or Excluded with the reason in plain words (a missing or out-of-range value, a missing failure reading, or an effective confining stress below zero). Excluded rows are left out of every result; the others are still computed.

No unit declared
Specimen Total
About this output

For every specimen: the net confining stress sigma3, the major principal stress sigma1 at failure and the circle radius t, half the deviator stress, in the stress unit shown.

No unit declared
R-squared of its total-stress fit
About this output

The R-squared of the total-stress fit of the sample shown.

No unit declared
Undrained shear strength of the sample shown
About this output

The undrained shear strength Su of the sample shown, when it is a UU sample with a usable specimen, in the stress unit shown.

Unit kPa
Test type of the sample shown
About this output

The test type of the sample shown on the charts: UU, CU or CD.

No unit declared
Specimens used
About this output

The number of specimens whose readings entered a result. A specimen is left out when its failure reading or its pore pressure is missing, or when its effective confining stress comes out below zero.

No unit declared
Effective-stress friction angle of that stratum
About this output

The effective-stress friction angle of that stratum, in degrees.

Unit deg
R-squared of the stratum fit
About this output

The R-squared of the stratum's effective-stress fit.

No unit declared
Summary
About this output

One line: samples interpreted by test type, specimens used, the failure point recorded and the stress unit shown.

No unit declared
Status code
About this output

A one-word code for the status line: OK, CHECK, INPUT_INVALID or UNSUPPORTED (a test type this calculator does not interpret). It is for programs reading the result, not for display.

No unit declared
Effective-stress cohesion of that stratum
About this output

The effective-stress cohesion c' of that stratum, fitted over all usable specimens of its samples, in the stress unit shown.

Unit kPa
First stratum fitted in effective stress
About this output

The first stratum, in table order, with two or more CU or CD samples, which is fitted as a whole in effective stress.

No unit declared
R-squared of its effective-stress fit
About this output

The R-squared of the effective-stress fit of the sample shown.

No unit declared
Model status
About this output

OK when every row was used and every sample interpreted cleanly; CHECK with the first excluded row or the first result that needs a second look, while every valid row is still computed; NOT VALID only when nothing can be computed (no specimen, a repeated id or a setting outside its list), and then every result is blank.

No unit declared
Sample Effective Fit
About this output

Effective-stress strength of each CU and CD sample, then of each stratum with two or more such samples: the cohesion in the stress unit shown, the friction angle in degrees and the R-squared of the fit. Blank where no line could be fitted.

No unit declared
Sample Status
About this output

Every sample row entered, in table order (Sample 1, Sample 2, ...), with its test type, the number of usable specimens and its status: interpreted or fitted, or Excluded or not fitted with the reason in plain words.

No unit declared
Sample shown on the charts
About this output

The sample whose Mohr circles and envelope the charts draw.

No unit declared
Circle Points
About this output

The points the charts draw for the chart sample: 37 points along the upper half of each Mohr circle (at most four total-stress and four effective-stress circles) and the two end points of each fitted failure line.

No unit declared
Effective-stress chart applies (1 yes, 0 no)
About this output

1 when the effective-stress chart has at least one circle to draw (the sample shown is a CU or CD sample with a used specimen), 0 otherwise (a UU sample, or an excluded one). For the page, which hides the effective-stress chart when it is 0; not shown as a result.

No unit declared
Sample Total Fit
About this output

Total-stress strength of each CU sample, then of each stratum with two or more CU samples: the cohesion in the stress unit shown, the friction angle in degrees and the R-squared of the fit. Blank where no line could be fitted.

No unit declared
Total-stress cohesion of the sample shown
About this output

The total-stress cohesion c of the sample shown, when it is a CU sample with a fitted line, in the stress unit shown.

Unit kPa
Effective-stress friction angle of the sample shown
About this output

The effective-stress friction angle of the sample shown, in degrees, when it is a CU or CD sample with a fitted line.

Unit deg
Total-stress friction angle of the sample shown
About this output

The total-stress friction angle of the sample shown, in degrees, when it is a CU sample with a fitted line.

Unit deg
Sample Undrained
About this output

Undrained shear strength Su of each UU sample, the mean circle radius of its usable specimens, listed by top depth, with the number of specimens.

No unit declared
Samples interpreted
About this output

The number of samples with a result: a UU sample with an undrained shear strength, or a CU or CD sample with a fitted effective-stress envelope.

No unit declared
Effective-stress cohesion of the sample shown
About this output

The effective-stress cohesion c' of the sample shown, when it is a CU or CD sample with a fitted line, in the stress unit shown.

Unit kPa
This page is provided by LogicCommons for informational purposes only. Results are analysis outputs computed from the inputs you supply and are not engineering advice, a design, or a substitute for review by a licensed professional under the codes adopted where the work is built. Verify all inputs and results independently.

LogicCommons is in beta. If a result, label, or reference looks wrong, tell us here; we read every message.

Methodology

Purpose and model boundary

This calculator interprets a series of triaxial compression tests. From each specimen's cell pressure, back pressure, deviator stress and, for consolidated undrained tests, excess pore pressure at failure, it finds the principal stresses and the Mohr circle at failure. It then fits a straight failure line to each sample's circles, and to each group of samples named as one stratum, giving the cohesion and friction angle in total and in effective stress. For unconsolidated undrained tests it reports the undrained shear strength instead.

It is an interpretation aid for education and preliminary work. Three test types are covered: unconsolidated undrained, consolidated undrained with pore pressure measured, and consolidated drained. Stress-path, anisotropically consolidated, cyclic and unsaturated tests are outside its scope. The failure point is read by the laboratory; the calculator does not pick it from a stress-strain curve.

Inputs and units

  • Samples: a sample name, the boring it came from and its top and bottom depth in metres.
  • Test type (every sample): the test type, and an optional stratum name so that samples sharing it are also fitted together.
  • Specimens: one row per specimen with its name, its sample, the cell pressure and the back pressure (blank for none), in kilopascals.
  • Failure readings: for each specimen, the deviator stress at failure and, for a consolidated undrained test, the excess pore pressure at failure, in kilopascals.
  • Fit settings: whether the line fits a cohesion intercept or passes through the origin, the least acceptable fit quality, which failure point the readings record (maximum deviator stress or maximum principal stress ratio, a label kept with the results), the stress unit for the results, and the sample shown on the charts (Sample 1 is the first row of the samples table).

Governing relationships

Total principal stresses at failure, net of the back pressure:

σ3 = cell pressure − back pressure and σ1 = σ3 + deviator stress

Effective stresses for a consolidated undrained test, with u the excess pore pressure at failure:

σ3′ = σ3 − u and σ1′ = σ1 − u

For a consolidated drained test the effective stresses equal the total stresses. Each circle has its centre and radius at

s = (σ1 + σ3) / 2 and t = (σ1 − σ3) / 2

A least-squares line t = a + s tan α through the circles' tops (the same closed forms as a direct shear line) gives

φ = arcsin(tan α) and c = a / cos φ

For an unconsolidated undrained test, the undrained shear strength of a specimen is Su = t, and a sample's is the mean of its specimens.

Calculation sequence

  1. Check the settings and that no sample or specimen is entered twice. Check each table row; a bad row, or a row naming a sample or specimen that is not entered, is excluded with its own status and every other row is still used.
  2. For each specimen compute the total stresses and, by test type, the effective stresses; exclude a consolidated undrained specimen without an excess pore pressure, and one whose effective confining stress is below zero.
  3. For an unconsolidated undrained sample, report the undrained shear strength.
  4. For each other sample, and each stratum, with at least two usable specimens at different confining stresses, fit the total-stress and the effective-stress lines; two specimens define a line exactly, so a third is needed to check it.
  5. Flag a negative fitted cohesion, a fit below the least acceptable quality and a friction angle outside 0 to 60 degrees.
  6. Draw the chosen sample's circles and fitted lines, in total and in effective stress, and convert the reported stresses to the chosen unit.

Outputs and interpretation

The summary gives the number of samples interpreted. The strength tables give each sample's and each stratum's cohesion, friction angle and fit quality, in effective and in total stress. The undrained table lists each unconsolidated undrained sample by depth with its undrained shear strength and specimen count. The specimen tables give the stresses at failure, and the status tables say whether each sample and specimen was used, and why not. The two charts show the chosen sample's Mohr circles and fitted lines in total and in effective stress, and its values are listed beside them. Effective stress applies to CU and CD tests only, so for a UU sample the effective-stress chart is replaced by a line saying so.

Worked examples

The lab values in the examples are illustrative data for the shared synthetic sample sites; they are not from a real property.

  1. Soft-clay CU tests with pore pressure. Three samples, three specimens each, under a back pressure.
  2. Stiff-clay UU strength profile. Six samples at 6, 9 and 12 m, one specimen each.
  3. Dense sand and gravel CD tests. Two samples at three confining stresses; compare with cohesion zero.
  4. Basement clay with back pressure. Four specimens under a high back pressure, combined as one stratum.
  5. Warehouse series with a data-entry error. Mixed test types, and one impossible pore pressure.

Validation and status logic

The status reads OK, CHECK: (results with a caution) or NOT VALID: (no results). The first rule that applies wins:

Condition Returned status
No specimen is entered NOT VALID: enter at least one sample with its specimens
A sample or specimen is entered twice in the same table NOT VALID: naming the row and the repeated name
A setting is not in its list or range NOT VALID: naming the setting
A row has a bad value, names a sample or specimen that is not entered, or a specimen has no failure row; a consolidated undrained specimen has no excess pore pressure or an effective confining stress below zero CHECK: naming the first excluded row and how many more; each row's status says why
A drained or unconsolidated undrained specimen has an excess pore pressure CHECK: naming the specimen; the value is not used
A sample has too few usable specimens, or a line steeper than a strength envelope allows CHECK: naming the sample; its row says why
A line rests on only two specimens, a cohesion below zero, a fit below the least acceptable quality, or a friction angle outside 0 to 60 degrees CHECK: naming the sample or stratum
The chart sample is beyond the samples entered CHECK: saying which sample the charts show instead
None of the above OK

Assumptions and limitations

  • The specimens were saturated, and the readings are at the failure point the laboratory chose.
  • The failure line is straight over the stresses tested.
  • Total-stress parameters from consolidated undrained tests describe that test path only.
  • Undrained strength depends on the specimen's depth, sampling disturbance and test rate.
  • The least acceptable fit quality is the reader's choice, not a value from a standard.

Restrictions and non-computing states

The page opens with empty tables; choose a worked example or enter your own rows, then press Calculate. The input rules refuse a value outside its allowed range before calculation. In the calculation, a bad row is excluded with its own status while the other rows are still used, a specimen without a usable effective stress is left out of its sample's fit, and a sample without enough usable specimens is reported without a line. Tests other than UU, CU and CD are not interpreted.

Errors and warnings

A rejected entry means the request did not satisfy the published input rules. NOT VALID means the series cannot be interpreted as entered, and names the first problem. CHECK means the results are reported but some need attention: read each row's status. A calculation-service failure is an availability error, not a test result.

References

Sources and further reading

  • ASTM International, Standard Test Method for Consolidated Undrained Triaxial Compression Test for Cohesive Soils, ASTM D4767-11 (reapproved 2020). store.astm.org. The test method for consolidated undrained tests with pore pressure measured.
  • ASTM International, Standard Test Method for Consolidated Drained Triaxial Compression Test for Soils, ASTM D7181-20. store.astm.org. The test method for consolidated drained tests.
  • ASTM International, Standard Test Method for Unconsolidated-Undrained Triaxial Compression Test on Cohesive Soils, ASTM D2850-26. store.astm.org. The test method for unconsolidated undrained tests.
  • Federal Highway Administration, Soils and Foundations Reference Manual, Volume I, FHWA NHI-06-088 (December 2006), section 5.5.2.2. fhwa.dot.gov. A public description of triaxial testing and of total and effective stress strength.

The standards are sold by ASTM; this page reproduces none of their tables or wording. The applicable test standards, project requirements and review by a qualified geotechnical professional govern the selection of design strength parameters.

Results are informational and not professional advice. See our Terms of Use. Powered by SpreadsheetWeb · About · Privacy · Terms