Soil mechanics

Soil Permeability Lab Test Interpretation

Turns constant-head and falling-head laboratory permeability readings into hydraulic conductivity by Darcy's law: a k for every trial, the mean k of every specimen at the test temperature and corrected to 20 degrees C, and the geometric and arithmetic means of every sample and stratum, in the unit you choose, with checks on the spread of the trials, laminar flow, the temperature range of the correction and your own target.

Last updated

Calculator overview

Inputs and outputs

This summary comes from the calculator's published input and output contract.

Inputs

Specimen Size (required)
About this input

The measured size of each specimen: its length along the flow and its diameter in millimetres, and for a falling-head test the inside diameter of the standpipe in millimetres.

Default 6 rows
ColumnRange or allowed values
SpecimenID Not declared
Length_mm 1 to 1000
Diameter_mm 1 to 1000
StandpipeDia_mm 0.1 to 100
Specimens (required)
About this input

One row per tested specimen: its id, the sample it was cut from, the test method (Constant head for coarse soils, Falling head for fine soils) and the water temperature during the test in degrees C.

Default 6 rows
ColumnRange or allowed values
SpecimenID Not declared
SampleID Not declared
Method Constant head, Falling head
Temp_C 0 to 100
Your target conductivity (optional)
When omitted Blank
About this input

Optional. Your own target hydraulic conductivity in metres per second, for example a liner specification. A specimen whose conductivity is above it is flagged for your attention; the calculator makes no compliance or pass-fail claim. Leave it blank for no comparison.

Unit m/s Default Not set Range 1E-14 to 1
Trial spread limit (required)
About this input

The largest difference, in percent of their mean, that a specimen's trials may show before the calculator flags them. The default of 25% follows the common laboratory practice of accepting readings within plus or minus 25% of their mean; enter your own limit from 1 to 100%. The same limit is used for the check that constant-head conductivity does not change with the head.

Unit % Default 25 Range 1 to 100
Sample Strata
When omitted Blank
About this input

Optional. The stratum each sample belongs to, such as Sand or Clay, so that results can be summarised by stratum. Leave it blank if you do not need a stratum table.

Default 6 rows
ColumnRange or allowed values
SampleID Not declared
Stratum Not declared
Unit for the result tables (required)
About this input

The unit for the conductivity values in the result tables: metres per second, centimetres per second, metres per day or feet per day. The conversions are exact (1 day = 86,400 s; 1 ft = 0.3048 m). The summary and the lowest and highest values stay in metres per second.

Default m/s Allowed m/s, cm/s, m/day, ft/day
Correct k to 20 degrees C (required)
About this input

Choose Yes to report each specimen's conductivity corrected to a water temperature of 20 degrees C, the usual basis for comparing tests, using the ratio of water viscosity at the test temperature to that at 20 degrees C. The correction covers tests run from 4 to 40 degrees C; choose No to report conductivity at the test temperature only.

Default Yes Allowed Yes, No
Samples (required)
About this input

One row per sample brought from the field: its sample id, and optionally the borehole it came from and its top and bottom depth below ground in metres. Specimens name their sample by this id.

Default 6 rows
ColumnRange or allowed values
SampleID Not declared
BoreholeID Not declared
TopDepth_m 0 to 500
BottomDepth_m 0 to 500
Readings (required)
About this input

One row per trial. For a constant-head specimen: the head loss across the specimen (mm), the volume of water collected (mL) and the time (s). For a falling-head specimen: the head at the start (mm), the head at the end (mm) and the time between them (s). The method comes from the specimen.

Default 24 rows
ColumnRange or allowed values
SpecimenID Not declared
Head_mm 0.1 to 100000
VolumeOrEndHead 0.001 to 1000000
Time_s 1 to 10000000

Outputs

Summary
About this output

One line: how many specimens were interpreted from how many trials, how many of them have k at the test temperature only (outside the 4 to 40 degrees C correction, when it is on), and the range of their conductivity in metres per second.

No unit declared
Conductivity by stratum (in the unit chosen for the tables)
About this output

The same means for each stratum you entered, over the specimens of its samples.

No unit declared
Status code
About this output

A short code for the kind of status: OK, CHECK or INPUT_INVALID, for software that reads the result without parsing the sentence.

No unit declared
Trials used
About this output

The number of trials used in the results, over all specimens.

No unit declared
Trials not used
About this output

The number of falling-head trials left out because the end head was not below the start head.

No unit declared
Conductivity of every trial at the test temperature (in the unit chosen for the tables)
About this output

Every trial's conductivity at the test temperature, in the unit you chose, and its difference from its specimen's mean in percent. A trial that was not used shows no value.

No unit declared
Specimens interpreted
About this output

The number of specimens with at least one usable trial, for which a conductivity is given.

No unit declared
Model status
About this output

OK when every specimen was interpreted with no warning. CHECK names the first point to look at, such as a trial that was not used, trials that spread more than your limit or a test outside the temperature correction; the results are still given. NOT VALID names the first input to fix, and no results are given.

No unit declared
Lowest specimen conductivity
About this output

The lowest specimen conductivity, in metres per second: at 20 degrees C when the correction is on, otherwise at the test temperature. Blank when no specimen has a value on that basis.

Unit m/s
Highest specimen conductivity
About this output

The highest specimen conductivity, in metres per second, on the same basis as the lowest.

Unit m/s
Trials and checks by specimen
About this output

Each specimen's number of usable trials, the largest difference of a trial from their mean in percent, and its status in plain words.

No unit declared
Conductivity by specimen (in the unit chosen for the tables)
About this output

Each specimen's hydraulic conductivity, the mean of its usable trials, at the test temperature and corrected to 20 degrees C, in the unit you chose.

No unit declared
Conductivity by sample (in the unit chosen for the tables)
About this output

Each sample's geometric mean and arithmetic mean conductivity over its specimens, in the unit you chose, at 20 degrees C when the correction is on. Conductivity spreads over orders of magnitude, so the geometric mean is the usual summary.

No unit declared
This page is provided by LogicCommons for informational purposes only. Results are analysis outputs computed from the inputs you supply and are not engineering advice, a design, or a substitute for review by a licensed professional under the codes adopted where the work is built. Verify all inputs and results independently.

LogicCommons is in beta. If a result, label, or reference looks wrong, tell us here; we read every message.

Methodology

Purpose and model boundary

This calculator interprets laboratory permeability tests. From each trial's readings it computes the hydraulic conductivity at the test temperature by the constant-head or the falling-head formula, corrects it to 20 °C for the viscosity of water, and reports each specimen's mean, the spread of its trials, and the geometric and arithmetic means by sample and by stratum, in the unit you choose.

It is an interpretation aid for education and preliminary work. The value describes the specimen as tested; field conductivity can differ from it by orders of magnitude because of layering, fissures, scale and stress, and a liner, dewatering or drainage design needs more than a lab value. Saturation, back pressure, consolidation and membrane leakage are not checked. A target you enter is only compared against; no regulatory limit is applied.

Inputs and units

  • Samples: a sample name, the boring it came from and its top and bottom depth in metres.
  • Specimens: one row per specimen with its name, its sample, the test method (constant head or falling head) and the water temperature in degrees Celsius.
  • Specimen sizes: the specimen length and diameter in millimetres, and for a falling-head test the standpipe's inside diameter.
  • Readings: one row per trial, named by its specimen; the specimen's method says how the row is read. For a constant-head specimen: the head loss across the specimen in millimetres, the volume collected in millilitres and the time in seconds. For a falling-head specimen: the head at the start and at the end in millimetres and the time in seconds.
  • Strata (optional): the stratum each sample belongs to, for the results by stratum.
  • Settings: whether to correct to 20 °C, the largest spread of a specimen's trials from their mean (25% unless you change it), an optional target conductivity of your own in m/s, and the unit for the result tables (m/s, cm/s, m/day or ft/day). The lowest and highest conductivity are always given in m/s.

Governing relationships

With A = π D² / 4 the specimen area, a = π d² / 4 the standpipe area and L the specimen length, all in metres, a constant-head trial collecting a volume Q in time t under a head loss h gives

kT = Q L / (A h t)

and a falling-head trial whose head falls from h1 to h2 in time t gives

kT = (a L / (A t)) ln(h1 / h2)

The value at 20 °C is

k20 = kT × μT / μ20

where μ is the viscosity of liquid water at atmospheric pressure, tabulated for every whole degree from 4 to 40 °C from the NIST Chemistry WebBook (the IAPWS 2008 formulation) and interpolated linearly between whole degrees.

A specimen's kT is the mean of its usable trials. Its spread is the largest difference of a trial from that mean, as a percentage of the mean, given when it has two or more usable trials. For a constant-head specimen tested at two or more heads, the laminar check is the difference between the mean at the highest and at the lowest head, as a percentage of the specimen's mean. Means by sample and stratum are given both as the geometric mean exp(mean of ln k), because conductivity varies over orders of magnitude, and as the arithmetic mean.

Calculation sequence

  1. Check the settings and the structure of the tables: every row has its id, every id is unique and every id it names exists.
  2. Check each specimen, specimen size and readings row. A bad value there leaves only that specimen not interpreted or that trial not used; the rest is still calculated.
  3. For each usable trial, convert the readings to metres, square metres and cubic metres and compute kT by its specimen's method. A falling-head trial whose end head is not below its start head is not used.
  4. For each specimen, compute the mean kT, the spread of its trials, the laminar check and, when correction is on and the water was between 4 and 40 °C, k20.
  5. Compare each specimen's value with your target, where you entered one.
  6. Combine the specimens by sample and by stratum, taking the means in m/s, and convert to the chosen unit.

Outputs and interpretation

The summary gives the number of specimens interpreted, the trials used and the range of conductivity; the lowest and highest specimen conductivity are given in m/s, with the trials used and not used. The specimen table gives each specimen's conductivity at the test temperature and at 20 °C in the unit shown. The trial checks give each specimen's number of trials, spread and status in words, and the trial table gives every trial's value and its difference from the specimen mean; a trial not used keeps its number and shows no value. The sample and stratum tables give the geometric and arithmetic means and the number of specimens with a value.

Worked examples

The lab values in the examples are illustrative data for the shared synthetic sample sites; they are not from a real property.

  1. Basement dewatering: permeability by stratum. Sand at constant head and clay at falling head, from four borings, with the results by stratum.
  2. Detention-pond liner check. Four compacted clay specimens against the owner's target.
  3. Highway cut drainage-blanket aggregate. Three gradations at three heads each, shown in metres per day.
  4. Subdivision stormwater infiltration screening. Sand and soft clay from the subdivision site.
  5. Warehouse lab sheet with problems. A warm test, a rising head and a wide spread.

Validation and status logic

The status reads OK, CHECK: (results with a caution) or NOT VALID: (no results). The first rule that applies wins:

Condition Returned status
A setting is outside its list or range NOT VALID: naming the setting
A row has no id, a sample or strata row is wrong, an id is repeated or names something that is not entered NOT VALID: naming the table, the row and what is wrong
No specimen is entered, or no specimen has a usable reading NOT VALID: saying so
A specimen has a bad method or temperature, no size row, a bad size row or (falling head) no standpipe diameter CHECK: naming it; that specimen is not interpreted
A readings row has a missing or out-of-range value, or a falling-head end head not below its start head CHECK: naming the row; that trial is not used
A specimen has no usable trial CHECK: naming the specimen
The water temperature is outside 4 to 40 °C with correction on CHECK: naming the specimen; only its value at the test temperature is given
A constant-head specimen's value changes with the head by more than the limit CHECK: naming the specimen; the flow may not be laminar
A specimen's trials spread from their mean by more than the limit CHECK: naming the specimen, its spread and the limit
A specimen's value is above your target CHECK: naming the specimen
None of the above OK

Assumptions and limitations

  • The specimens were saturated and the flow through them was laminar and steady during each trial.
  • Constant-head tests suit coarse-grained soils, and falling-head tests in a flexible-wall cell suit fine-grained soils.
  • The viscosity correction covers 4 to 40 °C; with correction on, a specimen tested outside it keeps only its value at the test temperature and is left out of the means.
  • A lab specimen is small, so it cannot represent layering, fissures or other features larger than itself.

Restrictions and non-computing states

The page opens with empty tables; choose a worked example or enter your own rows, then press Calculate. The input rules refuse a value outside its allowed range before calculation. NOT VALID is kept for problems with the structure of the tables; a bad value in one specimen or reading leaves only that specimen or trial out, named by a CHECK.

Errors and warnings

A rejected entry means the request did not satisfy the published input rules. NOT VALID means the readings cannot be interpreted as entered, and names the first problem. CHECK means the results are reported but some need attention: read each specimen's status. A calculation-service failure is an availability error, not a test result.

References

Sources and further reading

  • ASTM International, Standard Test Methods for Laboratory Measurement of Hydraulic Conductivity of Coarse-Grained Soils, ASTM D2434-26. store.astm.org. The constant-head test method for coarse-grained soils.
  • ASTM International, Standard Test Methods for Measurement of Hydraulic Conductivity of Saturated Porous Materials Using a Flexible Wall Permeameter, ASTM D5084-24. store.astm.org. The test methods for fine-grained soils, including the falling-head methods.
  • National Institute of Standards and Technology, NIST Chemistry WebBook, Thermophysical Properties of Fluid Systems (water at 0.101325 MPa). webbook.nist.gov. The viscosity of water from 4 to 40 °C used for the correction to 20 °C, computed with the IAPWS 2008 formulation (IAPWS R12-08).
  • U.S. Bureau of Reclamation, Earth Manual, Part 2, third edition (1990), procedures USBR 5600-89 (constant head) and USBR 5610-89 (falling head). usbr.gov. Worked laboratory examples this calculator's results were checked against.
  • Federal Highway Administration, Soils and Foundations Reference Manual, Volume I, FHWA NHI-06-088 (December 2006), section 5.6. fhwa.dot.gov. A public description of laboratory permeability testing and the typical range of hydraulic conductivity in soils.

The standards are sold by ASTM; this page reproduces none of their tables or wording. The applicable test standards, project requirements and review by a qualified geotechnical professional govern the use of laboratory hydraulic conductivity values.

Results are informational and not professional advice. See our Terms of Use. Powered by SpreadsheetWeb · About · Privacy · Terms