Motion & gravity

Vibration Isolation Tuner

Tunes a machine's isolator on a vibrating floor: one stage or two, a viscous damper or a rubber mount; the transmissibility at the floor's frequency as a ratio, a percent and decibels, with the machine's amplitude, phase lag and the force passed on; the response curve from 0.25 to 250 Hz for both damping models and two stages; the exact start-up (resonance) peak and the least damping that meets a peak limit; the exact worst case in a target band; the static sag; the best design in closed form and a 17 x 17 design map; the two-stage natural frequencies; and 96 frames of the steady-state motion. Refuses inputs out of range plainly, warns when a limit is broken or the mount amplifies, and scores five challenges. For learning vibration isolation, damping trade-offs and frequency response.

Last updated

Calculator overview

Inputs and outputs

This summary comes from the calculator's published input and output contract.

Inputs

Isolation stages (required)
About this input

One stage (one mount: a spring with a damper between the floor and the machine) or Two stages (floor, lower mount, intermediate mass, upper mount, machine), chosen from the list.

Default One stage Allowed One stage, Two stages
Machine mass (required)
About this input

M, the machine's mass, in kg, from 1 to 10,000 (the upper mass at two stages).

Unit kg Default 200 Range 1 to 10000
Intermediate mass (required) Conditional
About this input

m1, the intermediate mass between the two mounts, in kg, from 1 to 10,000. Shown and used for two stages only.

Unit kg Default 50 Range 1 to 10000
Mount natural frequency (required)
About this input

fn, the mount's natural frequency, in Hz, from 1 to 15: one stage, the mount under the machine; two stages, the lower mount under the machine plus the intermediate mass. A lower fn is a softer mount that sags more.

Unit Hz Default 5 Range 1 to 15
Upper mount natural frequency (required) Conditional
About this input

fn2, the upper mount's natural frequency under the machine, in Hz, from 1 to 15. Shown and used for two stages only.

Unit Hz Default 6 Range 1 to 15
Start-up peak limit (required) Conditional
About this input

The largest resonance peak transmissibility allowed for one stage (the machine passes through it when it runs up to speed), from 1.5 to 200. Shown and used for one stage only.

Default 15 Range 1.5 to 200
Sag limit (required)
About this input

The largest static sag the mounts may have under the machine's weight (the rattle space), in mm, from 1 to 300.

Unit mm Default 25 Range 1 to 300
Upper mount damping ratio (required) Conditional
About this input

zeta2, the upper mount's damping ratio, from 0.005 to 0.5; a rubber mount's loss factor is 2 x zeta2. Shown and used for two stages only.

Default 0.05 Range 0.005 to 0.5
Challenge number (required)
About this input

0 for none, or 1 to 5 to load a challenge. A challenge fixes the machine, the floor and every model input it is not about, and leaves only its free inputs to you.

Default 0 Range 0 to 5
Damping model (required)
About this input

Viscous damper (the damping force grows with the speed, so its effect grows with frequency), Rubber mount (a loss factor of 2 x the damping ratio at every frequency) or Not yet chosen, chosen from the list. At resonance the two dampers are identical. While Not yet chosen (challenge 4 starts there) the transmissibility, band and design results, the curves and the motion stay hidden until you choose.

Default Viscous damper Allowed Viscous damper, Rubber mount, Not yet chosen
Target band upper edge (required)
About this input

The target band's upper edge, in Hz, from 0.25 to 250 and above the lower edge.

Unit Hz Default 40 Range 0.25 to 250
Target band lower edge (required)
About this input

The target band's lower edge, in Hz, from 0.25 to 250 and below the upper edge.

Unit Hz Default 20 Range 0.25 to 250
Floor vibration frequency (required)
About this input

f, the floor's vibration frequency, in Hz, from 0.25 to 250.

Unit Hz Default 25 Range 0.25 to 250
Floor vibration amplitude (required)
About this input

Y, the floor's displacement amplitude, in mm, from 0.001 to 10.

Unit mm Default 0.1 Range 0.001 to 10
Your prediction (challenge 1) (required)
About this input

Your prediction in challenge 1: Not yet predicted, It falls, It rises or It stays the same, chosen from the list. The results stay hidden until you choose; it changes nothing outside challenge 1.

Default Not yet predicted Allowed Not yet predicted, It falls, It rises, It stays the same
Damping ratio (required)
About this input

zeta, the damping ratio of that mount, from 0.005 to 0.5; a rubber mount's loss factor is 2 x zeta.

Default 0.1 Range 0.005 to 0.5

Outputs

Phase lag of the machine
About this output

How far the machine's motion lags the floor's, in degrees from 0 to 180 (one stage; blank at two stages).

Unit deg
Design map damping axis: the damping ratio of each map column
About this output

The design map's damping axis: the column number 1 to 17 and its damping ratio (from 0.005 to 0.5, log-spaced). Blank at two stages.

No unit declared
Force the mount passes to the machine
About this output

The amplitude of the force the mount passes to the machine, M w^2 X, in N.

Unit N
Machine mass used
About this output

The machine mass used, kg (the challenge's when a challenge fixes it).

Unit kg
Model Status
About this output

OK, CHECK (the sag is over its limit, the start-up peak is over its limit, or the mount passes or amplifies the vibration at the floor's frequency) or NOT VALID with the reason. When NOT VALID every result and grid cell is blank; the challenge result, goal and feedback still show.

No unit declared
Model version
About this output

The model version.

No unit declared
Design map highest isolation
About this output

The highest isolation on the design map, in dB (its colour scale).

Unit dB
Design map lowest isolation
About this output

The lowest isolation on the design map, in dB (its colour scale).

Unit dB
Regime at the excitation
About this output

Amplifying (T above 1), Crossover (T within 1E-9 of 1) or Isolating (T below 1) at the floor's frequency.

No unit declared
Animation: 96 frames over two excitation periods of the steady-state motion of the floor, the intermediate mass (two stages) and the machine, and the force on the machine
About this output

The animation: 96 frames over two periods of the floor's vibration, each with the time, the floor's, the intermediate mass's (two stages) and the machine's displacement in mm, and the force on the machine in N (its mass times its acceleration). Columns 3 to 5 are withheld while challenge 1 awaits a prediction or the damping model is Not yet chosen.

No unit declared
Isolation in decibels
About this output

The isolation in decibels, -20 log10(T).

Unit dB
Isolation
About this output

The share of the floor's motion kept from the machine, 100 (1 - T), percent; negative when the mount amplifies.

Unit %
Rubber loss factor
About this output

The rubber mount's loss factor eta = 2 zeta; blank for a viscous damper.

No unit declared
Machine amplitude
About this output

The machine's displacement amplitude T x Y, in mm.

Unit mm
Mount natural frequency used
About this output

The mount natural frequency used, Hz (the challenge's when a challenge fixes it).

Unit Hz
Isolation stages used
About this output

The number of stages used (the challenge's when a challenge fixes it).

No unit declared
Start-up peak limit used
About this output

The start-up peak limit used (the challenge's when a challenge fixes it); blank at two stages.

No unit declared
Start-up peak within the limit
About this output

Yes when the start-up peak is within its limit, else No (one stage; blank at two stages).

No unit declared
Upper mount natural frequency used
About this output

The upper mount natural frequency used, Hz (the challenge's when a challenge fixes it); blank at one stage.

Unit Hz
Upper mount stiffness
About this output

The upper mount's stiffness k2 = M (2 pi fn2)^2, in N/m; blank at one stage.

Unit N/m
Two-stage upper natural frequency
About this output

The upper undamped natural frequency of the two-stage chain, in Hz; blank at one stage.

Unit Hz
Two-stage lower natural frequency
About this output

The lower undamped natural frequency of the two-stage chain, in Hz; blank at one stage.

Unit Hz
Static sag of the mounts
About this output

How far the mounts sink under the machine's weight (the sum of both at two stages), in mm, with standard gravity.

Unit mm
Mount stiffness
About this output

The mount's stiffness k = M (2 pi fn)^2 (one stage), or the lower mount's k1 = (M + m1)(2 pi fn)^2 (two stages), in N/m.

Unit N/m
Start-up (resonance) peak transmissibility
About this output

The one-stage resonance peak transmissibility, exact and closed form: the start-up peak the machine passes through when it runs up to speed; blank at two stages.

No unit declared
Response curve: transmissibility at 121 log-spaced frequencies from 0.25 to 250 Hz for the viscous damper, the rubber mount and (two stages) the two-stage isolator, with the phase lag of the selected model and the in-band flag
About this output

The response curve: 121 rows at frequencies from 0.25 to 250 Hz (40 a decade), each with the transmissibility of the viscous damper and of the rubber mount, the two-stage transmissibility (blank at one stage), the selected model's one-stage phase lag in degrees, and 1 when the frequency lies in the target band. Columns 2 to 6 are withheld while challenge 1 awaits a prediction or the damping model is Not yet chosen.

No unit declared
Formula module versions
About this output

The formula modules the model is built from, with their versions.

No unit declared
Resonance peak frequency
About this output

The frequency of the one-stage resonance peak (fn x rp), in Hz; blank at two stages.

Unit Hz
Upper mount damping coefficient
About this output

The upper mount's viscous damping coefficient c2, in N s/m; blank at one stage and for a rubber mount.

Unit N s/m
Upper mount damping ratio used
About this output

The upper mount damping ratio used (the challenge's when a challenge fixes it); blank at one stage.

No unit declared
Sag limit used
About this output

The sag limit used, mm (the challenge's when a challenge fixes it).

Unit mm
Sag within the limit
About this output

Yes when the static sag is within the sag limit, else No.

No unit declared
Intermediate mass used
About this output

The intermediate mass used, kg (the challenge's when a challenge fixes it); blank at one stage.

Unit kg
Challenge: the value scored
About this output

The value the selected challenge scores: the rise in transmissibility from damping 0.05 to 0.30 (challenge 1), the isolation percent (2), the band worst-case isolation in dB (3 and 4), or the isolation in dB at 100 Hz (5); blank with no challenge and while withheld (challenge 1 before a prediction, challenge 4 before a damper type).

No unit declared
Challenge score
About this output

100 when the selected challenge is met, else 0.

No unit declared
Challenge feedback
About this output

A prompt while challenge 1 awaits a prediction or challenge 4 awaits a damper type, else the met or not-met feedback of the selected challenge; blank with no challenge.

No unit declared
Challenge goal
About this output

The goal of the selected challenge; blank with no challenge.

No unit declared
Lowest transmissibility on the curve
About this output

The lowest transmissibility on the shown curves, the bottom of the log axis.

No unit declared
Damping coefficient
About this output

The viscous damping coefficient c = 2 zeta M (2 pi fn) (one stage) or c1 of the lower mount (two stages), in N s/m; blank for a rubber mount.

Unit N s/m
Challenge result
About this output

No challenge selected, MET or NOT MET.

No unit declared
Highest transmissibility on the curve
About this output

The highest transmissibility on the shown curves, the top of the log axis.

No unit declared
Target band lower edge used
About this output

The band lower edge used, Hz (the challenge's when a challenge fixes it).

Unit Hz
Frequency of the band worst case
About this output

Where in the band that worst case lies, in Hz.

Unit Hz
Target band upper edge used
About this output

The band upper edge used, Hz (the challenge's when a challenge fixes it).

Unit Hz
Band worst-case isolation
About this output

The band worst case in decibels, -20 log10 of it.

Unit dB
Worst transmissibility in the band
About this output

The largest transmissibility anywhere in the target band (one stage), exact from three evaluations; blank at two stages.

No unit declared
Band worst case with a viscous damper
About this output

The band worst case with a viscous damper of the same natural frequency and damping ratio.

No unit declared
Where the band worst case lies
About this output

Lower band edge (the whole band above the peak), Resonance peak inside the band, or Upper band edge (the whole band below the peak).

No unit declared
Band worst case with a rubber mount
About this output

The band worst case with a rubber mount of the same natural frequency and damping ratio.

No unit declared
Floor vibration amplitude used
About this output

The floor vibration amplitude used, mm (the challenge's when a challenge fixes it).

Unit mm
Frequency ratio (excitation over natural)
About this output

r = f/fn, the floor's frequency over the mount's natural frequency.

No unit declared
Floor vibration frequency used
About this output

The floor vibration frequency used, Hz (the challenge's when a challenge fixes it).

Unit Hz
Transmissibility at the excitation
About this output

T, the machine's amplitude over the floor's at the floor's frequency (the same ratio passes a force on the machine to the floor). Below 1 the mount isolates.

No unit declared
Design map best natural frequency
About this output

The natural frequency of the design map's best allowed cell, in Hz; blank when no cell is allowed.

Unit Hz
Gap from the map best to the exact best
About this output

How far the map's best cell trails the exact best, in dB: the map's resolution; blank unless the exact best exists.

Unit dB
Design map best damping ratio
About this output

The damping ratio of the design map's best allowed cell.

No unit declared
Design map best band isolation
About this output

The band worst-case isolation of the design map's best allowed cell, in dB.

Unit dB
Design map feasibility (one stage): 0 allowed, 1 sag over the limit, 2 start-up peak over the limit, 3 both
About this output

The design map's feasibility codes, laid out like designMap: 0 allowed, 1 the sag is over its limit, 2 the start-up peak is over its limit, 3 both. Blank at two stages; columns 2 to 18 are withheld while challenge 1 awaits a prediction or the damping model is Not yet chosen.

No unit declared
Design map (one stage): the band worst-case isolation in dB over 17 natural frequencies (rows) and 17 damping ratios (columns)
About this output

The design map (one stage): one row per natural frequency (17 from 1 to 15 Hz, log-spaced, in column 1), and in columns 2 to 18 the band worst-case isolation in dB for the 17 damping ratios of mapDampingAxis. Blank at two stages; columns 2 to 18 are withheld while challenge 1 awaits a prediction or the damping model is Not yet chosen.

No unit declared
Damping model used
About this output

The damping model used (the challenge's when a challenge fixes it); Not yet chosen until a damper type is chosen.

No unit declared
Damping ratio used
About this output

The damping ratio used (the challenge's when a challenge fixes it).

No unit declared
Exact best band isolation
About this output

The exact best design's band worst-case isolation, in dB.

Unit dB
Exact best natural frequency
About this output

The exact best design's natural frequency: the softest mount the sag limit allows, in Hz; blank unless the exact best exists.

Unit Hz
Best design status
About this output

Exact best (the whole band lies above 1.41 x the softest allowed mount, so the best design is known in closed form), Grid best only, or No allowed design (the sag limit needs a mount stiffer than 15 Hz). One stage only.

No unit declared
Exact best damping ratio
About this output

The exact best design's damping ratio: the least damping the start-up peak limit allows.

No unit declared
This page is provided by LogicCommons for informational purposes only. Results are analysis outputs computed from the inputs you supply and are not professional advice. Verify all inputs and results independently.

LogicCommons is in beta. If a result, label, or reference looks wrong, tell us here; we read every message.

Methodology

Purpose and model boundary

This lab tunes the isolator under a machine that stands on a vibrating floor. The floor moves up and down as Y·sin(ωt). The isolator is one stage (a spring with a damper between the floor and the machine) or two stages (floor, lower mount, an intermediate mass, upper mount, machine), and its damping is a viscous damper, whose force grows with speed, or a rubber mount, whose loss factor does not change with frequency. In closed form the lab returns the transmissibility at the floor's frequency as a ratio, a percentage and decibels, the machine's amplitude, its phase lag and the force the mount passes to it; the response curve from 0.25 to 250 Hz for both damping models and for two stages; the start-up (resonance) peak and the least damping that keeps it within a limit; the exact worst case in a target band; the static sag; the best one-stage design in closed form and a 17 by 17 design map; the two-stage natural frequencies; and 96 frames of the steady-state motion. Five scored challenges use the same model.

It is a lab for learning vibration isolation: why a mount isolates only above about 1.41 times its natural frequency, why damping helps at resonance but hurts far above it, why a softer mount isolates better but sags more, and what a second stage adds. It is not a design tool for a real installation. The machine and the floor move only up and down, the mounts are linear, and the start-up transient, rocking modes, floor flexibility and the frequency dependence of real rubber are not modelled.

The model is the calculation authority. The page sends the values you set to the model and draws only what it returns: the response curves with the target band, the floor, the intermediate mass and the machine moving frame by frame, the force on the machine, and the design map with your design, the grid best and the exact best marked. The page computes no transmissibility, peak, band value or motion itself.

Inputs and units

Input Meaning and unit
Isolation stages One stage or Two stages (default One stage).
Damping model Viscous damper or Rubber mount (default Viscous damper). Challenge 4 starts on a third choice, Not yet chosen, which holds the results back until you choose.
Machine mass M, from 1 to 10,000 kg (default 200 kg); the upper mass at two stages.
Intermediate mass m₁, from 1 to 10,000 kg (default 50 kg). Two stages only.
Mount natural frequency fn, from 1 to 15 Hz (default 5 Hz): one stage, the mount under the machine; two stages, the lower mount under the machine plus the intermediate mass.
Upper mount natural frequency fn₂, from 1 to 15 Hz (default 6 Hz): the upper mount under the machine. Two stages only.
Damping ratio ζ of that mount, from 0.005 to 0.5 (default 0.1). A rubber mount's loss factor is 2ζ.
Upper mount damping ratio ζ₂, from 0.005 to 0.5 (default 0.05). Two stages only.
Floor vibration frequency f, from 0.25 to 250 Hz (default 25 Hz).
Floor vibration amplitude Y, from 0.001 to 10 mm (default 0.1 mm).
Target band lower and upper edges From 0.25 to 250 Hz, the upper above the lower (defaults 20 and 40 Hz).
Sag limit The largest static sag the mounts may have, from 1 to 300 mm (default 25 mm).
Start-up peak limit The largest resonance peak transmissibility allowed, from 1.5 to 200 (default 15). One stage only.
Challenge number 0 for free exploration, or 1 to 5 to load a challenge.
Your prediction (challenge 1) Not yet predicted, It falls, It rises or It stays the same. Used only in challenge 1.

An input that does not apply to the chosen number of stages is not checked, not used and not shown: the intermediate mass and the upper mount's frequency and damping apply at two stages only, and the start-up peak limit at one stage only.

Where each input is set:

  • On the canvas only: the floor vibration frequency (drag the orange marker along the log frequency axis; arrow keys step 0.01 Hz, Shift ten steps, Enter gives an exact number), the two band edges (drag the edges of the shaded band, from Experiment), the number of stages (chips, at Advanced) and your prediction for challenge 1.
  • In the input panel: every other input. The design map is read-only.

Governing relationships

Mount properties. With ωn = 2π·fn, one stage has stiffness k = M·ωn², viscous coefficient c = 2ζ·M·ωn and loss factor η = 2ζ. At two stages the lower mount carries M + m₁: k₁ = (M + m₁)·(2π·fn)², c₁ = 2ζ·(M + m₁)·(2π·fn); the upper mount carries M: k₂ = M·(2π·fn₂)², c₂ = 2ζ₂·M·(2π·fn₂). The static sag of a mount of natural frequency fn under the mass it carries is g / (2π·fn)², with standard gravity g = 9.80665 m/s², in mm; at two stages the two sags add.

One stage. With the frequency ratio r = f / fn, a = 1 - r² and b = 2ζ·r for the viscous damper or b = 2ζ = η for the rubber mount, the machine's motion over the floor's is the complex ratio X/Y = (1 + jb) / (a + jb), and the transmissibility is

T = √((1 + b²) / (a² + b²)).

The same ratio passes a force on the machine to the floor. The phase lag of the machine behind the floor is the angle of (a + b², b·r²), from 0 to 180 degrees. At r = 1 the two damping models give the same T, and both cross T = 1 at r = √2 for every damping value: below about 1.41 times the natural frequency the mount passes or amplifies the vibration, above it the mount isolates.

From T: isolation = 100·(1 - T) %, negative when the mount amplifies; isolation in decibels = -20·log₁₀(T); machine amplitude = T·Y; force on the machine = M·ω²·T·Y.

Two stages. With the mount impedances Z₁ = k₁ + j·b₁ and Z₂ = k₂ + j·b₂ (b = ω·c for viscous damping, b = k·η for a rubber mount), the machine's motion over the floor's is

X₂/Y = Z₁·Z₂ / (Z₁·Z₂ - ω²·(M·Z₁ + (m₁ + M)·Z₂) + ω⁴·m₁·M),

and the intermediate mass's is Z₁·(Z₂ - ω²·M) over the same denominator. The undamped natural frequencies of the chain are the roots λ = (2π·f)² of m₁·M·λ² - (M·(k₁ + k₂) + m₁·k₂)·λ + k₁·k₂ = 0.

Start-up peak (one stage, closed form). Viscous: with s = √(1 + 8ζ²), the peak lies at r_p = √(2 / (1 + s)) and its height is T_p = √((1 + s)³ / (8ζ²·(s + 3))). Rubber: r_p = 1 and T_p = √(1 + η²) / η. The machine passes through this peak as it runs up to speed. Since T_p falls as damping rises, the least damping that keeps it within a limit L is, for viscous damping, ζ = √((q / (1 + u)) / (2u²)) with q = 1/L² and u = √(1 - q), and for a rubber mount ζ = 1 / (2√(L² - 1)).

Band worst case (one stage, exact). T rises up to the peak and falls after it, so the largest T in the band [f_lo, f_hi] is T at the lower edge when the whole band lies above the peak, T_p when the peak lies inside the band, and T at the upper edge when the whole band lies below the peak. The lab reports it for the chosen model and for both models.

Exact best design (one stage). The softest mount the sag limit allows has f* = √(g / sag limit) / (2π), kept between 1 and 15 Hz, and the least damping the peak limit allows is ζ* (at least 0.005). When the whole band lies above √2·f* (T at the lower edge below 1), the mount (f*, ζ*) gives the lowest band worst case of every allowed design: any stiffer mount puts the lower edge closer to resonance, and above √2 more damping only raises T. Otherwise only the grid best is reported.

Design map (one stage). The band worst case in dB over 17 natural frequencies from 1 to 15 Hz and 17 damping ratios from 0.005 to 0.5, both evenly spaced on a log scale, with each point coded 0 allowed, 1 sag over the limit, 2 start-up peak over the limit, or 3 both. The grid best is the best allowed point; the gap to the exact best shows the map's resolution.

Response curve and motion. The curve has 121 frequencies from 0.25 to 250 Hz, 40 a decade. The 96 frames cover two periods of the floor's vibration, 48 frames a period: the floor moves as Y·sin θ and the machine as Y·(Re H·sin θ + Im H·cos θ), where H is the complex ratio above; the force on the machine is its mass times its acceleration.

Calculation sequence

  1. Check the inputs that apply, in the order of the list under Errors and warnings.
  2. Take the values used: in a challenge, its own settings, except the inputs it leaves to you. The prediction is never replaced.
  3. Compute the mount properties and the static sag.
  4. Compute the response at the floor's frequency (one or two stages) and the regime.
  5. Compute the start-up peak, the band worst case for both models, the constraints, the exact best design and the design map (one stage), or the two natural frequencies (two stages).
  6. Compute the response curve and the animation frames.
  7. Set the status and, in a challenge, score it.

Outputs and interpretation

At the floor's frequency: the frequency ratio r; the transmissibility T (below 1 the mount isolates); isolation in % and in decibels; the regime (Amplifying when T is above 1, Crossover within 1×10⁻⁹ of 1, Isolating below 1); the phase lag of the machine (one stage); the machine amplitude (mm); and the force the mount passes to the machine (N).

The mount: stiffness and, for a viscous damper, the damping coefficient (one stage, or the lower mount at two stages); the rubber loss factor 2ζ; the upper mount's stiffness and damping coefficient (two stages); the static sag (mm) and whether it is within the limit.

Start-up and band (one stage): the resonance peak frequency and start-up peak transmissibility, whether the peak is within the limit, the worst transmissibility in the band, where it lies and at what frequency, the band worst-case isolation in dB, and the band worst case with a viscous damper and with a rubber mount.

Design (one stage): the best design status (Exact best, Grid best only, or No allowed design when the sag limit needs a mount stiffer than 15 Hz), the exact best natural frequency, damping ratio and band isolation, the design map best point and its isolation, the gap between them, and the map's lowest and highest isolation.

Two stages: the lower and upper natural frequencies of the chain.

Reading the canvas: the response curves plot T on a log scale against frequency on a log scale, with the band shaded and the floor's frequency marked; every curve crosses T = 1 at 1.41 times the natural frequency. With viscous damping the curve beyond resonance falls at 40 dB a decade for one stage and 80 dB a decade for two stages only while the damper terms are small, then flattens to 20 and 40 dB a decade; the rubber mount keeps the steeper fall. The motion panel replays the steady state: the machine's swing against the floor's shows the transmissibility and the phase lag at a glance.

Challenges

Every challenge uses a 200 kg machine and a 0.1 mm floor amplitude and fixes every input it is not about; the page names the inputs each challenge lets you change. The model scores each challenge MET (100 points) or NOT MET (0), shows the value it scored, and gives a one-line hint while it is not met.

  1. Damping above the crossover. Predict: if the damping ratio rises from 0.05 to 0.30, does the transmissibility at 4 times the natural frequency (20 Hz) fall, rise or stay the same? The value scored is the rise in transmissibility between those two damping ratios at that frequency; it is met when you predict It rises.
  2. Ninety percent. Isolate at least 90% of the floor vibration at 25 Hz while the mount sags no more than 10 mm. The value scored is the isolation in %.
  3. Best in the band. Make the worst transmissibility in the 20 to 40 Hz band as low as possible: within 1 dB of the best possible, with a sag of at most 25 mm and a start-up peak of at most 5. It is met when the exact best exists, your band worst case is within a factor of 10^(1/20) of it, and both limits hold. The value scored is the band worst-case isolation in dB.
  4. Viscous or rubber. Choose the damper type that gives the lower worst transmissibility in the 36 to 44 Hz band, far above resonance. It is met when the chosen model's band worst case is below the other's. The value scored is the band worst-case isolation in dB.
  5. Two stages. Reach at least 80 dB of isolation at 100 Hz with two stages and a total sag of at most 25 mm. It is met when T at 100 Hz is at most 0.0001 and the sag is within the limit. The value scored is the isolation in dB.

Two challenges hold results back until you answer. In challenge 1, while your prediction reads Not yet predicted, and in challenge 4, while the damping model reads Not yet chosen, the transmissibility, isolation, phase lag, machine amplitude and force, the band results (both models' band values included), the design results, the curves, the motion of the masses and the design map's values are blank, and the challenge reads NOT MET with a prompt to answer first. The mount properties, the sag, the regime, the start-up peak and the limits stay shown (for Not yet chosen, as for a viscous damper). Your prediction changes nothing outside challenge 1.

What to take from the lab: isolation needs the floor's frequency well above 1.41 times the mount's natural frequency; a softer mount isolates more but sags more; damping tames the start-up peak but lets more vibration through far above resonance; and a second stage makes the curve fall much faster.

Validation and status logic

The status reads the first match in the list under Errors and warnings. The NOT VALID checks run on the values you entered, also while a challenge is selected, and only on the inputs that apply: the intermediate mass and the upper mount's frequency and damping at two stages, the start-up peak limit at one stage. The CHECK items run on the values used, also inside challenges; the start-up peak check applies at one stage only. A challenge number that is not a whole number from 0 to 5 counts as no challenge selected.

Assumptions and limitations

  • Vertical motion only; linear mounts; a rigid machine, intermediate mass and floor. No rocking or other modes.
  • The rubber mount is modelled by a loss factor of 2ζ that does not change with frequency; real rubber stiffens and changes its damping with frequency and amplitude. With the rubber model the motion frames are the frequency-domain steady state, not a time-domain rubber law.
  • Steady state only: the start-up peak is the height of the resonance peak the machine passes through, not a simulated run-up.
  • The start-up peak check, the band worst case and the design tools are one-stage results; the two-stage peak has no closed form here.
  • Natural frequencies from 1 to 15 Hz, damping ratios from 0.005 to 0.5, frequencies from 0.25 to 250 Hz.
  • A value within 1×10⁻⁹ (relative) of a threshold may flip a status or a challenge.

Restrictions and non-computing states

Under NOT VALID every result, curve, frame and map value is blank; a selected challenge reads NOT MET with a score of 0, and its goal and hint stay shown. At two stages the one-stage results (phase lag, start-up peak, band results, design results and the design map) are blank. In challenges 1 and 4, until you answer, results are held back as described under Challenges.

Errors and warnings

The status messages, first match wins:

  • NOT VALID: choose the number of isolation stages from the list
  • NOT VALID: choose a damping model from the list
  • NOT VALID: the machine mass and the intermediate mass must be from 1 to 10,000 kg: the intermediate mass at two stages only.
  • NOT VALID: the natural frequencies must be from 1 to 15 Hz and the damping ratios from 0.005 to 0.5: the upper mount's values at two stages only.
  • NOT VALID: the excitation frequency must be from 0.25 to 250 Hz and the floor amplitude from 0.001 to 10 mm
  • NOT VALID: the band edges must be from 0.25 to 250 Hz, with the upper edge above the lower edge
  • NOT VALID: the sag limit must be from 1 to 300 mm and the start-up peak limit from 1.5 to 200: the start-up peak limit at one stage only.
  • NOT VALID: the challenge number must be a whole number from 0 to 5, and the damping prediction one of the listed choices
  • CHECK: the mount sags more than the sag limit allows; choose a stiffer mount (a higher natural frequency) or allow more sag
  • CHECK: the start-up peak is above its limit, so the machine shakes too hard while it runs up through resonance; add damping or allow a higher peak: one stage only.
  • CHECK: at the excitation frequency the mount passes or amplifies the vibration (transmissibility 1 or more); choose a softer mount so the excitation sits well above resonance
  • OK: the inputs are valid and none of the above applies.

References

This laboratory is an educational model of passive vibration isolation under base excitation. A machine on a spring and damper, or on two such stages with a mass between them, is driven by the harmonic motion of the floor. The transmissibility, the ratio of the machine's motion to the floor's, follows from the complex frequency response of a single- or two-degree-of-freedom system, with viscous damping or with hysteretic (rubber) damping described by a constant loss factor. The lab adds the closed-form resonance peak and its inverse, the static sag that links a mount's natural frequency to its stiffness, the worst case over a frequency band, and the two natural frequencies of the two-stage chain.

Sources and further reading

  • Vibration isolation design from the base-motion transfer function, the natural frequency predicted from the static deflection as the square root of g over the deflection, and the natural frequencies and mode shapes of a two-degree-of-freedom system: J. K. Vandiver and D. Gossard, Engineering Dynamics (2.003SC), MIT OpenCourseWare, Fall 2011, session Reducing Problem Vibration and Intro to Multi-DOF Vibration, lectures 21 and 22. MIT OpenCourseWare
  • Harmonic base excitation, transmissibility, hysteretic damping and vibration isolation: S. S. Rao, Mechanical Vibrations, Pearson, the chapters on harmonically excited vibration and on vibration control.
  • The dynamic properties and damping of elastomers used as dampers and mounts: M. Darlow and E. Zorzi, Mechanical Design Handbook for Elastomers, NASA Contractor Report 3423, NASA, 1981. NASA Technical Reports Server
  • An overview of passive isolation with springs and dampers, the transmissibility curve, the trade-off between damping at resonance and isolation at higher frequencies, elastomer mounts and stacked isolation stages: Vibration isolation, Wikipedia. Wikipedia

No table or text from any of these publications is reproduced, and none of their authors or publishers has reviewed or endorses this laboratory.